Commit Graph

23244 Commits

Author SHA1 Message Date
Jonas Ådahl
38235bc145 Add MetaFraction for dealing with fractions
Add MetaFraction, which consists of two integers, the numerator an the
denominator. The utility function to convert a double to a MetaFraction
comes from gstreamer.

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 14:39:04 +08:00
Jonas Ådahl
3ce3a5a952 monitor: Add API to compare with old instance
When monitors changed, previous monitor instances are defunct, and any
reference holder should drop its reference. Sometimes they will want to
continue having a reference to the same monitor, so add this function
to make it possible to find it.

Currently the output and crtc references are invalid, as they are not
yet reference counted, so this can only look at cached fields.

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 14:38:20 +08:00
Jonas Ådahl
3005a400ca monitor-manager: Add helper for getting monitor from connector
This will be used later.

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 11:49:01 +08:00
Jonas Ådahl
34e7134db2 wayland/xdg-foreign: Move out ID generation helper to util.c
It'll be used to generate ID in the same way in other places later.

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 11:49:01 +08:00
Jonas Ådahl
12710dc644 clutter/stage: Add capture_into API
Add API similar to clutter_stage_capture() but that draws into
externally allocated memory. It is assumed that the pixel format is
ARGB32, and the memory is structured in a way that the width of the
passed rectangle is identical to the stride divided by 4.

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 11:49:01 +08:00
Jonas Ådahl
a10ad577a7 ClutterVirtualInputDevice: Add discrete scrolling
Add emitting of discrete scrolling events (such as mouse scroll
wheel-like events).

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 11:49:01 +08:00
Jonas Ådahl
d3c559a917 clutter/evdev: Move scroll notification to ClutterSeatEvdev
This refactors the scroll event emitting code, moving it behind a
clutter_seat_evdev_ helper.

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 11:49:01 +08:00
Jonas Ådahl
1e7628a3ef ClutterVirtualInputDevice: Allow passing CLUTTER_CURRENT_TIME
If CLUTTER_CURRENT_TIME is passed, let the backend find an appropriate
time stamp representing the current time in the clock that is used by
that backend.

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 11:49:01 +08:00
Ask Hjorth Larsen
d5a85997f2 Updated Danish translation 2017-08-28 19:32:44 +02:00
Matej Urbančič
5a37e0e1ef Updated Slovenian translation 2017-08-28 19:20:26 +02:00
Rūdolfs Mazurs
00f6a74397 Update Latvian translation 2017-08-27 23:50:05 +03:00
Милош Поповић
c9439107c1 Update Serbian Latin translation 2017-08-27 20:29:58 +00:00
Марко Костић
ba65664cbd Update Serbian translation 2017-08-27 20:28:54 +00:00
Cheng-Chia Tseng
3da0730a31 Update Chinese (Taiwan) translation 2017-08-27 04:08:18 +00:00
Jordi Mas
98fcd616a3 Update Catalan translation 2017-08-25 13:23:23 +02:00
Daniel Stone
06d0989014 wayland-dma-buf: Fix 32bpp channel order inversion
Apparently my understanding of Cogl pixel formats, or at least their
use, was somewhat shaky.

Un-invert the inversion of the DRM FourCC -> Cogl pixel format mapping
when creating dmabufs from clients, fixing inverted channel ordering
seen from GL clients, e.g. gold highlights in gtk4-demo when using the
GSK GL backend when they should be blue.

https://bugzilla.gnome.org/show_bug.cgi?id=786677
2017-08-24 15:11:37 +02:00
Milo Casagrande
c248feb3c1 Update Italian translation 2017-08-24 07:45:30 +00:00
Dušan Kazik
3f2c5ca9bd Update Slovak translation 2017-08-23 17:50:59 +00:00
gogo
520c56fe53 Update Croatian translation 2017-08-23 15:40:53 +00:00
Fran Dieguez
d3a670b043 Update Galician translation 2017-08-23 10:22:13 +00:00
Piotr Drąg
6eca267eee Update Polish translation 2017-08-23 04:16:46 +02:00
Aurimas Černius
fdefe776d3 Updated Lithuanian translation 2017-08-22 23:18:07 +03:00
Marek Cernocky
bba8776184 Updated Czech translation 2017-08-22 18:48:01 +02:00
Mario Sanchez Prada
e075242801 egl: Don't require eglGetPlatformDisplayEXT
Trying to unilaterally require eglGetPlatformDisplayEXT causes problems in
scenarios where this method is not available. Besides, this should only be
required on Wayland, so we can stop requiring it always and simply let the
eglGetPlatformDisplay() function error accordingly when needed.

https://bugzilla.gnome.org/show_bug.cgi?id=786619
2017-08-22 18:33:13 +02:00
Florian Müllner
0f9686fb5a Bump version to 3.25.91
Update NEWS.
2017-08-22 00:21:48 +02:00
Alessandro Bono
168479862d meta-background-actor: Unset flags when they are not valid anymore
Currently, the flags that describe what is changed are never unsetted.
Unset each flag just after using them.

https://bugzilla.gnome.org/show_bug.cgi?id=783512
2017-08-21 22:18:28 +02:00
Mario Sanchez Prada
483ed98777 cogl: Only do the swizzling hack for GL contexts
The GL_BGRA definition is not available for GLES2 contexts, which use
the EXT_texture_format_BGRA8888 instead, causing a build failure when
trying to use it in those contexts.

Fortunately, this hack is only relevant for GL, so let's guard it to
prevent the failure in GLES2, where that extension is used instead.

https://bugzilla.gnome.org/show_bug.cgi?id=786568
2017-08-21 16:29:39 +02:00
Jonas Ådahl
14fe6e9c95 cursor-renderer-native: Don't use HW cursor on transformed logical monitor
The HW cursor plane can't do any transformations, and as we still don't
pre-transform any buffer before uploading to the cursor plane, we must
disable the HW cursor when a logical monitor is transformed.

This worked previously because the transform of a MetaCrtc did not
correspond to the transform of a CRTC, but the transform of the logical
monitor the CRTC was assigned to.

https://bugzilla.gnome.org/show_bug.cgi?id=786023
2017-08-21 21:20:19 +08:00
Jonas Ådahl
6584d06bb5 monitor-manager: Don't cancel confirm dialog on verifying
When another D-Bus call that just tries to verify a configuration is
made, don't cancel any active monitor configuration dialog, as doing so
would effectively confirm queried configuration.

https://bugzilla.gnome.org/show_bug.cgi?id=786023
2017-08-21 21:20:19 +08:00
Jonas Ådahl
92a53f08f4 keybindings: Only resolve keysyms for the current layout group
When resolving what keycodes a key binding resolves to, only look up
key codes from the current layout group. Without this, unwanted
overlaps may occur. For example when a keymap has both a dvorak and a
qwerty layout on different layout groups, one keybinding may be bound
on multiple keys, arbitrarily "shadowing" another.

https://bugzilla.gnome.org/show_bug.cgi?id=786408
2017-08-21 21:19:18 +08:00
Jonas Ådahl
a81d4aed7a backend/x11: Notify whenever the layout group changes
Will be used to trigger keyboard binding rebuild.

https://bugzilla.gnome.org/show_bug.cgi?id=786408
2017-08-21 21:19:18 +08:00
Jonas Ådahl
517488ef67 backends/native: Only emit layout group changed event when changed
Check that the layout group changed before emitting a changed event.
2017-08-21 21:19:18 +08:00
Jonas Ådahl
33f1706634 backend: Add API to get layout group
Add API to get the layout group (layout index) currently active. In the
native backend this is done by fetching the state directly from the
evdev backend; on X11 this works by listening for XkbStateNotify
events, caching the layout group value.

https://bugzilla.gnome.org/show_bug.cgi?id=786408
2017-08-21 21:19:18 +08:00
Jonas Ådahl
5685449e15 clutter/evdev: Add API to get current layout index
We set the layout index when changing keyboard layout, but have no way
to get it back would so be needed. Add that.

https://bugzilla.gnome.org/show_bug.cgi?id=786408
2017-08-21 21:19:18 +08:00
Jonas Ådahl
a6d67b164a x11: Open backend X11 connection ourself
Don't wait for clutter to initialize for connecting to X11; do it when
constructing the backend instance. This way we can later depend on
having an X11 connection earlier during initialization.

https://bugzilla.gnome.org/show_bug.cgi?id=786408
2017-08-21 21:19:18 +08:00
Jonas Ådahl
f950380202 monitor-manager-xrandr: Use G_DECLARE_FINAL_TYPE macro
Declare the MetaMonitorManagerXrandr type using the helper macro,
instead of manually.

https://bugzilla.gnome.org/show_bug.cgi?id=786408
2017-08-21 21:19:18 +08:00
Kukuh Syafaat
a4270fa7ac Update Indonesian translation 2017-08-21 07:33:47 +00:00
Jonas Ådahl
35c9280fb6 monitor-manager: Try to restore previous config before regenerating
When opening a laptop lid, one will likely want to restore the
configuration one had prior to closing it, so when ensuring monitor
configuration, first try to see if the previously set configuration is
both complete (all connected monitors are configured) and applicable
(it is a valid configuration) and only try to generate a new from
scratch if that failed.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
8b92ad1d4b tests/monitor-unit-tests: Clear config history before each test
To not let different tests interfere with each other, clear the config
history before each run.
2017-08-21 12:23:51 +08:00
Jonas Ådahl
0d6e3fd675 tests/monitor-unit-tests: Use special purpose add test helper
Will later be used to set a setup function.
2017-08-21 12:23:51 +08:00
Jonas Ådahl
b140e7fbeb monitor-config-manager: Keep short history of configurations
In order to go back in monitor configurations, save them to a history.
The history is implemented as a max 3 element long queue, where newly
set configurations are pushed to the head, and old are popped from the
tail.

The difference between using a single previous config reference and a
queue is that we can now remember the configuration used prior to a
D-Bus triggered configuration when the user discarded the configuration.

This will later be used to restore a previous configuration when a
laptop lid is opened.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
6c0f107db0 tests: Add rotated multi head monitor config migration test
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
61950755ec tests: Add monitor config migration tests
So far some basic testing, including:

 * Test that the migrated configuration is applicable
 * Test that a monitors.xml with multiple configurations are translated
 * Test rotation
 * Test tiled monitor discovery (well, test a made up tiled monitor
   configuration since I don't have a real one)

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
bc3162460f Migrate old monitor configuration files to new system
This commit changes the new configuration system to use monitors.xml
instead of monitors-experimental.xml. When starting up and the
monitors.xml file is loaded, if a legacy monitors.xml file is
discovered (it has the version number 1), an attempt is made to migrate
the stored configuration onto the new system.

This is done in two steps:

1) Parsing and translation of the old configuration. This works by
parsing file using the mostly the old parser, but then translating the
resulting configuration structs into the new configuration system. As
the legacy configuration system doesn't carry over some state (such as
tiling and scale used), some things are not available. For tiling, the
migration paths makes an attempt to discover tiled monitors by
comparing EDID data, and guessing what the main tile is. Determination
of the scale of a migrated configuration is postponed until the
configuration is actually applied. This works by flagging the
configuration as 'migrated'.

2) Finishing the migration when applying. When a configuration with the
'migrated' flag is retrieved from the configuration store, the final
step of the migration is taken place. This involves calculating the
preferred scale given the mode configured, while making sure this
doesn't result in any overlapping logical monitor regions etc.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
27a4f9f862 monitor-manager/kms: Use connector id to find old output
The zero-initialized winsys id was incorrectly used as the key to find
the old output to base active/primary state from, which would never
succeed unless the winsys id happened to be 0. Fix this by using the
winsys id that will be used, i.e. the connector id.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
88f2441330 monitor-manager: Fix output variable naming
Fix the last case of using the variable name "meta_output" for a
MetaOutput.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
ab04286c6b monitor-manager/x11: Don't complain about 'normal' transform
The 'normal' transform has the value 0, so the g_warn_if_fail()
expression failed. Correct it so that it doesn't complain when no
transform is checked.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
e8a62861c9 Remove old monitor configuration system
Remove the old MetaMonitorConfig system and mark the new one as
non-experimental. This also removes the D-Bus property.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:20:53 +08:00
Jonas Ådahl
9ac87b36c1 monitor-manager/xrandr: Fix name inconsistencies
MetaOutputs should be "output" and external types should be named as
such, i.e. XRandr outputs are renamed to "xrandr_output".

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:20:30 +08:00
Pawan Chitrakar
ce7819949f Update Nepali translation 2017-08-20 09:01:04 +00:00