Commit Graph

6164 Commits

Author SHA1 Message Date
Jonas Ådahl
6fa8238ebf monitor-unit-tests: Check monitor <-> logical monitor relationships
Make sure that each logical monitor owns the expected actual monitors.
This currently needs special care when dealing with laptop lid the
configuration, as the MetaMonitorConfigManager path still deosn't
handle restoring the previous configuration, meaning the logical
monitor with the external monitor will continue being primary.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:57 +08:00
Jonas Ådahl
1c6eef48f1 monitor-unit-tests: Move logical monitor checking into separate function
Split the big check function, makes things easier to read.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:57 +08:00
Jonas Ådahl
1fdf2ac746 monitor-unit-tests: Check that each CRTC mode is correct
This is partly redundant given that the current monitor mode is checked
against the CRTC mode, but this also checks the disabled CRTCs. Later
the configured mode position and transform will be checked.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
3ae9feef0c monitor-unit-tests: Check monitor mode CRTC mode positions
Check that the crtc mode has the correct intra-monitor position. In
effect, this tests that the CRTCs in a tiled monitor are configured with
the correct mode on the correct position.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
e9a8208607 tests: Add monitor store and config test for output underscanning
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
e357b4a46a monitor-store: Add support for monitor underscanning
Add a <monitor> subelement <underscanning> for configuring
output underscanning.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
097ca01411 legacy-monitor-config: Init is_underscanning config field from output
Don't loose the is_underscanning field when creating a new configuration.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
e8197e8e05 monitor-config-manager: Add underscanning to MetaMonitorConfig
Set the underscanning state via the monitor config struct so that it
can be configured.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
7fc6b8a746 legacy-monitor-config: Fix primary output state
The MetaOutput::is_primary state was not correctly managed in two cases:

 * for tiled monitors, the primary state got overridden when setting
   the preferred resolution
 * for laptop lid, it was not set if the laptop panel happened to be
   the first output

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
0fd9c00580 tests: Add monitor and monitor store test for custom primary
Test that having a custom primary logical monitor is configured as
expected.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
4a51a1dfe5 monitor-unit-tests: Check handling of the primary presentation flags
The main output of the main (first) monitor of a primary logical
monitor should have the MetaOutput::is_primary field set; all other
outputs should have it not set.

All outputs associated with a logical monitor with presentation set
should have MetaOutput::is_presentation set. No other outputs should
have it set.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
9fb8abf840 monitor-store-unit-tests: Check the primary and presentation flags
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
449320cd23 monitor-unit-tests: Check that a stored config is preferred
Check that the stored config (where the logical monitors are placed
vertically) is preferred to the otherwise generated linear config.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
12b69dbabb monitor-unit-tests: Make hotplug_mode_update optional
Add a flag to the test setup creation function enabling the caller to
specify whether a stored config should be used. This is done by
changing the value of the hotplug_mode_update MetaOutput field,
normally used by VMs to do the same.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
4652bde3d7 tests: Move monitor test helpers to a helper file
Both the monitor unit tests and monitor store unit tests will want to
check whether the config manager is used and set custom configuration
files.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
9b4e1903e1 monitor-config-manager: Prefer to use stored config
If not explicitly set by the backend, prefer to use the stored config
instead of creating a new one, if available.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
702facbc91 monitor-store-unit-tests: Add test for vertical placement
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
339340df34 tests: Add MetaMonitorConfigStore tests
Add tests that check that a XML configuration file results in correct
MetaMonitorsConfig objects.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
1ad386bc28 Introduce MetaMonitorConfigStore
MetaMonitorConfigStore provides an XML storage mechanism for
MetaMonitorConfigManager. It stores configuration files defined in the
same level as the MetaMonitorsConfig format, i.e. refers to high level
"monitors" and "monitor modes" instead of connectors and CRTCs.

Only reading custom files are implemented and so far unused.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
28a8c714ea unit-tests: Pass argc/argv directly to g_test_init
Don't let a dummy option context consume the arguments; just let the
GLib test suite do it. It'll handle the basic command line arguments
and allow doing things such as specifying what test to run.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
c9f18bfef3 monitor-unit-tests: Test headless mode
This tests only the monitor configuration and basic functionality. It
does not test anything related to window management and Wayland client
interaction.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
20cd885443 backend: Only center pointer when not headless
When we are headless, there is no logical monitor to try to center the
pointer on, so just skip it.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
3f994646f2 monitor-config-manager: Handle headless setup gracefully
Handle headless setup gracefully by having no logical monitors. This
commit only makes the monitor management code deal with it; other areas
may still not be able to handle it.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
f45e7703ba monitor-unit-tests: Add lid-closed with no external monitor test case
Test that when the laptop lid is closed, but no external monitors are
connected, that we still have a mode set on the laptop panel.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
1ee0412177 monitor-unit-tests: Use g_assert_cmp* macros when suitable
Use the g_assert_cmp(int|uint|...) macros when comparing integers and
unsigned integers. This means that the mismatched numbers are printed
in the test report.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
4b33f05eda monitor-config-manager: Add MetaMonitorsConfig creation helper
Add a meta_monitors_config_new() helper. It's exposed outside of
meta-monitor-config-manager.c already, as it'll be used externally in a
later commit.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
81923410f6 monitor-unit-tests: Test starting with lid closed
Add a test case that checks that configuration works when the lid is
initialy closed then later opened. This test case is disabled when the
legacy configuration is used as it does not handle that situation.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
f19cb6a610 monitor-config-manager: Handle laptop lid being closed
Handle configuring when the laptop lid is closed. This is so far
handled by creating a linear configuration while ignoring the laptop
panel. Changing the current configuration will come later.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
cde1a730e8 monitor-unit-tests: Add laptop lid switch test case
Test that the laptop panel is disabled if the lid is closed.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
d6efdfab4b monitor-unit-tests: Mock laptop lid state
For now, always assume the laptop lid is open, as all test cases assume
this.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
f7b6271d86 monitor-manager: Move UpClient signal listening into monitor manager
Move the UpClients notify::lid-is-closed signal handling into
MetaMonitorManager, and put the getter behind a vfunc. This means
Placing it behind a vfunc allows custom backends to implement it
differently; for example the test backend can mock the state.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
8d1be7ffc0 monitor-unit-tests: Add test for handling too few CRTCs
Check that configuration when there are more outputs than CRTCs does
something sane.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
a0af7e94a6 monitor-config-manager: Add support for suggested configuration
Create a suggested configuration, if such configuration is provided.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
f607b03456 monitor: Add API to query suggested position
Adds an API to get the position suggested by the backend. This
translates to position advertised by some VM:s, used to hint at a
position making the position more natural (i.e. placed similarly to how
it may be placed on the host desktop).

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
644ee666f6 Introduce new monitor configuration system
The new monitor configuration system (MetaMonitorConfigManager) aims to
replace the current MetaMonitorConfig. The main difference between the
two is that MetaMonitorConfigManager works with higher level input
(MetaMonitor, MetaMonitorMode) instead of directly looking at the CRTC
and connector state. It still produces CRTC and connector configuration
later applied by the respective backends.

Other difference the new system aims to introduce is that the
configuration system doesn't manipulate the monitor manager state; that
responsibility is left for the monitor manager to handle (it only
manages configuration and creates CRTC/connector assignments, it
doesn't apply anything).

The new configuration system allows backends to not rely on deriving the
current configuration from the CRTC/connector state, as this may no longer be
possible (i.e. when using KMS and multiple framebuffers).

The MetaMonitorConfigManager system is so far disabled by default, as
it does not yet have all the features of the old system, but eventually
it will replace MetaMonitorConfig which will at that point be removed.
This will make it possible to remove old hacks introduced due to
limitations in the old system.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
ee0677a021 monitor-manager: Let backend implementations handle inital config
How the initial configuration is done depends on the backend, so let
them do it themself.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
0b4d80d74f wayland/output: Operate on monitors instead of outputs
Operate on MetaMonitor's instead of MetaOutput's, as the latter may be
only a subset of an actual "monitor" when referring to the physical
computer equipment.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
1a2b493d17 tests/monitor-unit-tests: Check current monitor mode
Check both that current mode is up to date, and that deriving it again
won't change it.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
9ceeddd952 monitor: Track current monitor mode
Track what monitor mode is the current. This is derived from the mode
of the corresponding CRTC's.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
e1849ccbfa monitor: Add getter for vendor and serial
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
6262b46928 wayland/output: Pass 'unknown' subpixel order when mismatch
When a logical monitor constains monitors with different subpixel
ordering, make the wl_output have the subpixel order 'unknown' so that
clients don't make assumptions given only a subset of the monitors of
the given region.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
8752f40792 monitor-manager-kms: Some harmless style fixes
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
8c5600e81b monitor-manager-kms: Handle EDID blob not being ready immediately
Sometimes we hit a race on hot-plug where we try to read the KMS
resources and the EDID blob is not yet ready. This would normally
result in a ENOENT when retrieving the blob. Handle this by retrying
after 50 milliseconds after a hot-plug event. Do this up to 10 times,
and after that give up trying to get the EDID blob and continue with
best effort.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
4c1b48d0cc monitor: Add API to get monitor mode from spec
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
536ae8430b monitor-manager: Add API to get monitor from monitor spec
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
aaddf44d45 monitor-manager: Add API to find primary monitor
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
0c42faf34d monitor-manager: Some trivial style fixes
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
be13d0f8ee monitor: Allow monitor mode foreach crtc iterator failable
Allow the function used to iterate over the CRTC modes of a monitor
mode to fail, causing the iteration to fail as well.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
81438eebef monitor-unit-tests: Test suggested-x/y configuration
Test the suggested-x/y output state often set by virtual machines.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
b70187c2d9 monitor-manager: Move meta_monitor_manager_ function to right place
Move a meta_monitor_manager_ function to meta-monitor-manager.c where
it belongs.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
c041851fa5 monitor-manager: Rename read_current_config to read_current_state
The function meta_monitor_manager_read_current_config() was renamed to
meta_monitor_manager_read_current_state() as it does not read any
configuration, but reads the current state as described by the backend.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
b59a8b1de3 monitor-manager: Move configuration paths behind 'legacy' functions
In preparation of replacing the configuration system with one working
with high level monitors instead of low level outputs etc, move
configuarion handling code into obviously named function (containing
the word 'legacy'.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
e3b9fe7e58 monitor-manager: Use MetaMonitor to check laptop panel status
Instead of looking at the current configuration, just find the
MetaMonitor of the laptop display panel and check the currest status
directly.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
0177ab45af MetaMonitor: Add _is_laptop_panel() helper
Add a helper to determine whether the monitor is the laptop panel or
not. To be used by the configuration system.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
bc951557e8 monitor: Add monitor spec object
A monitor spec object is meant to be used to identify a certain monitor
on a certain output. The spec is unique per actual monitor and connector,
meaning that a monitor that changes from one connector from another
(e.g. HDMI1 to HDMI2) will not be identified as the same. It is meant
to associate for example a configuration entry with an actual monitor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
2c32d94e1d monitor: Determine preferred monitor mode
Determine the preferred monitor mode given what the preferred CRTC mode
is, and expose it via the API.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
5d9e2d8d2e MetaMonitor: Add mode spec concept
Add a "mode spec" concept, meaning to be used as a identifier for an
actual monitor mode. It consists of details making a mode unique, i.e.
the total resolution and refresh rate. This will later be used to get
the actual monitor mode (set of one or more CRTC modes).

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
0637537355 monitor-config: Modernize type declaration
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
63ed134165 monitor-unit-tests: Check monitor modes
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
a6f464a600 monitor: Add monitor modes abstraction
Add "monitor modes" abstracting the modes set on a monitor. On normal
monitors, this directly maps to the CRTC modes, but on tiled monitors,
a monitor mode can consist modes per tiled output.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
0a0c49af71 logical-monitor: Remove outdated comment
Remove the comment about tiling things being calculated. It doesn't add
anything valuable, and tiling is hidden behind MetaMonitor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
3c6d688c87 logical-monitor: Don't mirror refresh rate
Let the callers figure out how to associate a logical monitor with a
refresh rate, instead of exposing an arbitrary one.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
5d66a13397 logical-monitor: Don't mirror physical dimensions
Don't try to mirror the physical dimension, since that's a property of
one of the monitors, not of the logical monitor. Callers are changed to
deal with choosing the monitor to represent the logical monitor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
ff633f295e logical-monitor: Don't duplicate output list
Just use the monitor list and the output lists of each monitor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
310064601c monitor-unit-tests: Check tiled monitor adding/removing notification
Check that the moniter manager backends get the tiled monitor
added/removed notification.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
78799e58d2 monitor-manager: Make tiled Xrandr monitors based on monitors
Don't deal with adding/removing tiled Xrandr monitors in the generic
backend, but leave it to the Xrandr backend. The tiled monitor will
itself notify the backend when such a monitor is added and removed.

Tiled Xrandr monitors are now based no MetaMonitor instead of
MetaLogicalMonitor. This means that mirrored tiled monitors will now be
represented correctly.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
4fa8b74dc7 monitor-unit-tests: Add musing about test declarations
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
bf8b4e9927 monitor-manager: Generate logical monitors from monitors
Instead of using crtcs and outputs to generate logical monitors, use
the ready made monitor abstraction that hides irrelevant things such as
monitor tiling etc.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
f48acd8448 tests: Check that the crtc gets a logical monitor set
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
d0c9d2dc7b tests: Check that the monitors are properly generated
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
d9a0f2a88d monitor-manager: Generate a monitor abstraction from outputs and crtcs
Generate a set of "monitors" abstracting the physical concepts. Each
monitor is built up of one or more outputs; multiple outputs being
tiled monitors. Logical monitors will later be built from these.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
4e812410cc monitor-manager: Move logical monitor into its own file
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
0873e3812b backends: Rename MetaMonitorMode to MetaCrtcMode
The MetaMonitorMode referred to the mode of a CRTC, and with the future
introduction of a MetaMonitor, theh old name would be confusing.
Instead call it what it is.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
7eac28189b monitor-manager: Fix private header guard
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
1650c35e38 monitor-manager: Rename MetaCRTC(Info) to MetaCrtc(Info)
Change to follow the naming convention used everywhere else. This means
changing CRTC to Crtc even though it is an abbreviation.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
156c478ccb tests/monitor: Add HiDPI test
This doesn't test the actual calculation, since that is done in the
backend, it only tests the configuration.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
10e6eae0dd tests/monitor: Add tiled monitor test
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
f519093f89 monitor-manager: Initialize tiled logical monitor scale
The logical monitor scale were not initialized properly when created
for a tiled monitor. Set it to the scale of the main monitor tile.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
8a8ab6c673 tests/monitor: Test preferred mode
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
9e28303588 tests/monitor: Test one out of two outputs being off
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
6776329cf5 tests/monitor: Test two crtcs, one output
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
2e4c516d43 tests/monitor-manager: Add API to emulate a hotplug event
Let a test case pass a test setup, which will be used as the new state
emulated by the test backend.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
d920eaba4a tests: Also make test case verification declarative
Set up the expected result in a declarative way in the same place as
the test case setup is declared. This way we have a completely
declarative way to create test cases.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
376a76a082 tests: Make monitor test case setup more declarative
In order to more easily create more test cases, make the test case
setup more declarative.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
c6d940d3b2 tests: Make monitor unit tests create initial config
This way we have both the test setup and testing in the same file.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
95c101a0ba tests: Use custom Wayland display name
This gets rid of a warning about the Wayland display name already being
taken.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
239671f882 wayland: Add API to override display name
Add API that the tests can use in order to override the Wayland display
name.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
12150c1ca7 tests: Add basic monitor configuration tests
The added test checks that two monitors are lied out on a row next to
each other.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
a251675cc0 tests: Use special purpose backend in unit tests
Use a special purpose backend when running the unit tests. This will
eventually allow testing things like configuration and hot plugging.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
d188949101 backends/x11: Make the X11 backend derivable
Make the X11 backend derivable so that we can base a nested test backend
on it.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
d3920ddb67 core: Add private API to override compositor configuration
Add private API for overriding the compositor configuration, i.e. the
compositor type (X11 WM or Wayland compositor) and backend type. This
will make it possible to add a special test backend used by src/tests/.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
bc5077f623 screen: Put xinerama monitor index outside of MetaLogicalMonitor
Put the monitor xinerama index in a separate struct that is attached to
the logical monitor using g_object_set/get_qdata(). Eventually this
should be moved to some "X11 window manager" object, but lets keep it
in MetaScreen until we have such a thing.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
68f3b5849a workspace: Don't keep state given logical monitor indices
Don't store logical monitor specific state in an array where the index
from the monitor manager is used as index locally. Instead just use
table associating a logical monitor with a monitor specific state
holder, and store the state in there. This way we don't have the
workspace implementation relying on implementation details of other
units.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
6de3e4a07e Turn MetaLogicalMonitor into a GObject
This will make it easier to move various manually managed data and data
now in MetaLogicalMonitor into GObject QData fields.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
1fb0e8e9bb monitor-manager: Store logical monitors in a GList
Instead of storing the logical monitors in an array and having users
either look up them in the array given an index or iterate using
indices, put it in a GList, and use GList iterators when iterating and
alternative API where array indices were previously used.

This allows for more liberty regarding the type of the logical monitor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
20b8743f21 monitor-manager: Refactor tiled monitor assembly code
Refactor the tiled monitor assembly code (that constructs a logical
monitor out of tiling information. Part of the reason is to move away
from array based storage, part is to make the code easier to follow,
and part is to separate logical monitor construction from list
manipulation.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
016359ede2 window: Remove public meta_window_get_all_monitors API
It's not used anywhere and used monitor indices which is unoptimal.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
410bad88a8 screen: Don't use monitor indices in check_fullscreen_func
Rewrite check_fullscreen_func to not use indexes (and
offset-index-as-pointer) tricks. This also removes the usage of an API
constructing temporary logical monitor arrays carrying indices.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
c98bab8327 monitor-manager: Make logical monitor from point API take floats
Change meta_monitor_manager_get_logical_monitor_at() to use floats,
replace users of meta_monitor_manager_get_monitor_at_point() to use the
API that returns a logical monitor and remove the now unused function.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
a422d6fe08 Move logical monitor neighbor API into monitor manager
Move the last piece of monitor grid getter API to the monitor manager
away from MetaScreen. The public facing API are still there, but are
thin wrappers around the MetaMonitorManager API.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00