Commit Graph

22205 Commits

Author SHA1 Message Date
Jonas Ådahl
4a51a1dfe5 monitor-unit-tests: Check handling of the primary presentation flags
The main output of the main (first) monitor of a primary logical
monitor should have the MetaOutput::is_primary field set; all other
outputs should have it not set.

All outputs associated with a logical monitor with presentation set
should have MetaOutput::is_presentation set. No other outputs should
have it set.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
9fb8abf840 monitor-store-unit-tests: Check the primary and presentation flags
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
449320cd23 monitor-unit-tests: Check that a stored config is preferred
Check that the stored config (where the logical monitors are placed
vertically) is preferred to the otherwise generated linear config.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
12b69dbabb monitor-unit-tests: Make hotplug_mode_update optional
Add a flag to the test setup creation function enabling the caller to
specify whether a stored config should be used. This is done by
changing the value of the hotplug_mode_update MetaOutput field,
normally used by VMs to do the same.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
4652bde3d7 tests: Move monitor test helpers to a helper file
Both the monitor unit tests and monitor store unit tests will want to
check whether the config manager is used and set custom configuration
files.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
9b4e1903e1 monitor-config-manager: Prefer to use stored config
If not explicitly set by the backend, prefer to use the stored config
instead of creating a new one, if available.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
702facbc91 monitor-store-unit-tests: Add test for vertical placement
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
339340df34 tests: Add MetaMonitorConfigStore tests
Add tests that check that a XML configuration file results in correct
MetaMonitorsConfig objects.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
1ad386bc28 Introduce MetaMonitorConfigStore
MetaMonitorConfigStore provides an XML storage mechanism for
MetaMonitorConfigManager. It stores configuration files defined in the
same level as the MetaMonitorsConfig format, i.e. refers to high level
"monitors" and "monitor modes" instead of connectors and CRTCs.

Only reading custom files are implemented and so far unused.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
28a8c714ea unit-tests: Pass argc/argv directly to g_test_init
Don't let a dummy option context consume the arguments; just let the
GLib test suite do it. It'll handle the basic command line arguments
and allow doing things such as specifying what test to run.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
c9f18bfef3 monitor-unit-tests: Test headless mode
This tests only the monitor configuration and basic functionality. It
does not test anything related to window management and Wayland client
interaction.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
20cd885443 backend: Only center pointer when not headless
When we are headless, there is no logical monitor to try to center the
pointer on, so just skip it.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
3f994646f2 monitor-config-manager: Handle headless setup gracefully
Handle headless setup gracefully by having no logical monitors. This
commit only makes the monitor management code deal with it; other areas
may still not be able to handle it.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
f45e7703ba monitor-unit-tests: Add lid-closed with no external monitor test case
Test that when the laptop lid is closed, but no external monitors are
connected, that we still have a mode set on the laptop panel.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
1ee0412177 monitor-unit-tests: Use g_assert_cmp* macros when suitable
Use the g_assert_cmp(int|uint|...) macros when comparing integers and
unsigned integers. This means that the mismatched numbers are printed
in the test report.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
4b33f05eda monitor-config-manager: Add MetaMonitorsConfig creation helper
Add a meta_monitors_config_new() helper. It's exposed outside of
meta-monitor-config-manager.c already, as it'll be used externally in a
later commit.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
81923410f6 monitor-unit-tests: Test starting with lid closed
Add a test case that checks that configuration works when the lid is
initialy closed then later opened. This test case is disabled when the
legacy configuration is used as it does not handle that situation.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
f19cb6a610 monitor-config-manager: Handle laptop lid being closed
Handle configuring when the laptop lid is closed. This is so far
handled by creating a linear configuration while ignoring the laptop
panel. Changing the current configuration will come later.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
cde1a730e8 monitor-unit-tests: Add laptop lid switch test case
Test that the laptop panel is disabled if the lid is closed.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
d6efdfab4b monitor-unit-tests: Mock laptop lid state
For now, always assume the laptop lid is open, as all test cases assume
this.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
f7b6271d86 monitor-manager: Move UpClient signal listening into monitor manager
Move the UpClients notify::lid-is-closed signal handling into
MetaMonitorManager, and put the getter behind a vfunc. This means
Placing it behind a vfunc allows custom backends to implement it
differently; for example the test backend can mock the state.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
8d1be7ffc0 monitor-unit-tests: Add test for handling too few CRTCs
Check that configuration when there are more outputs than CRTCs does
something sane.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
a0af7e94a6 monitor-config-manager: Add support for suggested configuration
Create a suggested configuration, if such configuration is provided.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
f607b03456 monitor: Add API to query suggested position
Adds an API to get the position suggested by the backend. This
translates to position advertised by some VM:s, used to hint at a
position making the position more natural (i.e. placed similarly to how
it may be placed on the host desktop).

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
644ee666f6 Introduce new monitor configuration system
The new monitor configuration system (MetaMonitorConfigManager) aims to
replace the current MetaMonitorConfig. The main difference between the
two is that MetaMonitorConfigManager works with higher level input
(MetaMonitor, MetaMonitorMode) instead of directly looking at the CRTC
and connector state. It still produces CRTC and connector configuration
later applied by the respective backends.

Other difference the new system aims to introduce is that the
configuration system doesn't manipulate the monitor manager state; that
responsibility is left for the monitor manager to handle (it only
manages configuration and creates CRTC/connector assignments, it
doesn't apply anything).

The new configuration system allows backends to not rely on deriving the
current configuration from the CRTC/connector state, as this may no longer be
possible (i.e. when using KMS and multiple framebuffers).

The MetaMonitorConfigManager system is so far disabled by default, as
it does not yet have all the features of the old system, but eventually
it will replace MetaMonitorConfig which will at that point be removed.
This will make it possible to remove old hacks introduced due to
limitations in the old system.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
ee0677a021 monitor-manager: Let backend implementations handle inital config
How the initial configuration is done depends on the backend, so let
them do it themself.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
0b4d80d74f wayland/output: Operate on monitors instead of outputs
Operate on MetaMonitor's instead of MetaOutput's, as the latter may be
only a subset of an actual "monitor" when referring to the physical
computer equipment.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
1a2b493d17 tests/monitor-unit-tests: Check current monitor mode
Check both that current mode is up to date, and that deriving it again
won't change it.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
9ceeddd952 monitor: Track current monitor mode
Track what monitor mode is the current. This is derived from the mode
of the corresponding CRTC's.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
e1849ccbfa monitor: Add getter for vendor and serial
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
6262b46928 wayland/output: Pass 'unknown' subpixel order when mismatch
When a logical monitor constains monitors with different subpixel
ordering, make the wl_output have the subpixel order 'unknown' so that
clients don't make assumptions given only a subset of the monitors of
the given region.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
8752f40792 monitor-manager-kms: Some harmless style fixes
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
8c5600e81b monitor-manager-kms: Handle EDID blob not being ready immediately
Sometimes we hit a race on hot-plug where we try to read the KMS
resources and the EDID blob is not yet ready. This would normally
result in a ENOENT when retrieving the blob. Handle this by retrying
after 50 milliseconds after a hot-plug event. Do this up to 10 times,
and after that give up trying to get the EDID blob and continue with
best effort.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
4c1b48d0cc monitor: Add API to get monitor mode from spec
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
536ae8430b monitor-manager: Add API to get monitor from monitor spec
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
aaddf44d45 monitor-manager: Add API to find primary monitor
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
0c42faf34d monitor-manager: Some trivial style fixes
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
be13d0f8ee monitor: Allow monitor mode foreach crtc iterator failable
Allow the function used to iterate over the CRTC modes of a monitor
mode to fail, causing the iteration to fail as well.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
81438eebef monitor-unit-tests: Test suggested-x/y configuration
Test the suggested-x/y output state often set by virtual machines.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
b70187c2d9 monitor-manager: Move meta_monitor_manager_ function to right place
Move a meta_monitor_manager_ function to meta-monitor-manager.c where
it belongs.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
c041851fa5 monitor-manager: Rename read_current_config to read_current_state
The function meta_monitor_manager_read_current_config() was renamed to
meta_monitor_manager_read_current_state() as it does not read any
configuration, but reads the current state as described by the backend.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
b59a8b1de3 monitor-manager: Move configuration paths behind 'legacy' functions
In preparation of replacing the configuration system with one working
with high level monitors instead of low level outputs etc, move
configuarion handling code into obviously named function (containing
the word 'legacy'.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
e3b9fe7e58 monitor-manager: Use MetaMonitor to check laptop panel status
Instead of looking at the current configuration, just find the
MetaMonitor of the laptop display panel and check the currest status
directly.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
0177ab45af MetaMonitor: Add _is_laptop_panel() helper
Add a helper to determine whether the monitor is the laptop panel or
not. To be used by the configuration system.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
bc951557e8 monitor: Add monitor spec object
A monitor spec object is meant to be used to identify a certain monitor
on a certain output. The spec is unique per actual monitor and connector,
meaning that a monitor that changes from one connector from another
(e.g. HDMI1 to HDMI2) will not be identified as the same. It is meant
to associate for example a configuration entry with an actual monitor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
2c32d94e1d monitor: Determine preferred monitor mode
Determine the preferred monitor mode given what the preferred CRTC mode
is, and expose it via the API.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
5d9e2d8d2e MetaMonitor: Add mode spec concept
Add a "mode spec" concept, meaning to be used as a identifier for an
actual monitor mode. It consists of details making a mode unique, i.e.
the total resolution and refresh rate. This will later be used to get
the actual monitor mode (set of one or more CRTC modes).

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
0637537355 monitor-config: Modernize type declaration
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
63ed134165 monitor-unit-tests: Check monitor modes
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
a6f464a600 monitor: Add monitor modes abstraction
Add "monitor modes" abstracting the modes set on a monitor. On normal
monitors, this directly maps to the CRTC modes, but on tiled monitors,
a monitor mode can consist modes per tiled output.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00