Commit Graph

23 Commits

Author SHA1 Message Date
Björn Daase
5ec9bde64f *: Fix spelling mistakes found by codespell
https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1410
2020-08-29 09:10:31 +00:00
Jonas Ådahl
476ef76de6 tests/test-runner: Add 'assert_size' command
The 'assert_size' command checks that the size of the window, both
client side and compositor side, corresponds to an expected size set by
the test case.

The size comparison can only be done when the window is using 'csd', in
order for both the client and server to have the same amount of
understanding of the title bar. For ssd, the client cannot know how
large the title bar, thus cannot verify the full window size.

Sizes can be specified to mean the size of the monitor divided by a
number. This is that one can make sure a window is maximized or
fullscreened correctly.

https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1171
2020-05-07 23:15:24 +00:00
Jonas Ådahl
7f6cafa847 logical-monitor: Pass monitor in the for each CRTC helper callback
Will be used in later commits.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/1042
2020-02-25 18:39:51 +01:00
Jonas Ådahl
bea7600471 logical-monitor: Pass output when iterating over CRTCs
While not currently used by any users, it'll be useful in future
commits.

https://gitlab.gnome.org/GNOME/mutter/issues/548
https://gitlab.gnome.org/GNOME/mutter/merge_requests/525
2019-06-20 13:31:56 +00:00
Marco Trevisan (Treviño)
e02fef8e2f meta: Hide libmutter symbols by default and selectively export them
Make meson link libmutter using -fvisibility=hidden, and introduce META_EXPORT
and META_EXPORT_TEST defines to mark a symbols as visible.
The TEST version is meant to be used to flag symbols that are only used
internally by mutter tests, but that should not be considered public API.

This allows us to be more precise in selecting what is exported and what is
not, without the need of a version-script file that would be more complicated
to maintain.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/395
2019-01-23 14:18:13 +01:00
Emilio Pozuelo Monfort
5e005316ef output: Turn winsys_id into a uint64_t
We need a 64 bit field to combine the device id and connector
id into the output id (winsys_id).
2018-11-19 14:58:48 +00:00
Armin Krezović
e1c67a1824 Move monitor management API to MetaDisplay
This includes changing various users to use MetaDisplay directly, who
used MetaScreen only for this before.

https://bugzilla.gnome.org/show_bug.cgi?id=759538
2018-07-06 19:47:16 +02:00
Jonas Ådahl
903537a2a0 logical-monitor: Add helper for iterating over active CRTCs
Add meta_logical_monitor_foreach_crtc() helper to iterate over all the
active CRTCs driving the monitors associated with the specified logical
monitor.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
14fe6e9c95 cursor-renderer-native: Don't use HW cursor on transformed logical monitor
The HW cursor plane can't do any transformations, and as we still don't
pre-transform any buffer before uploading to the cursor plane, we must
disable the HW cursor when a logical monitor is transformed.

This worked previously because the transform of a MetaCrtc did not
correspond to the transform of a CRTC, but the transform of the logical
monitor the CRTC was assigned to.

https://bugzilla.gnome.org/show_bug.cgi?id=786023
2017-08-21 21:20:19 +08:00
Jonas Ådahl
b64c69e4bc logical-monitor: Make scale a float
To support fractional scaling, the logical monitor scale must be stored
as a float. No other functional changes is part of this commit.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
1bb0e18042 monitor-manager/xrandr: Allow configuring scales on X11 too
This commit makes it possible to configure logical monitor scale also
when running on top of an X11 server using Xrandr. An extra property
'requires-globla-scale' is added to the D-Bus API is added to instruct
a configuration application to only allow setting a global logical
monitor scale.

This is needed to let gsd-xsettings use the configured state to set a
XSettings state that respects the explicit monitor configuration.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-05-26 14:31:48 +08:00
Jonas Ådahl
d38c4c1f2d logical-monitor: Track whether the logical monitor is transformed
Keep track of the logical monitor transform. When a logical monitor is
transformed, all of its monitors are also transformed in the same way.
A logical monitor can either be transformed on the CRTC level, or using
an offscreen intermediate buffer. In both cases will the logical
monitor be transformed, but only in the latter will the view be
transformed.

MetaCrtcs::transform currently does not represent whether the CRTC is
configured to be transformed or not; only when the backend can handle
it does it correctly correspond to the actual CRTC configuration. This
is intended to change with MetaMonitorConfigManager.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:49 +08:00
Jonas Ådahl
8163ca6821 Add support for scaled logical monitor framebuffers
This commit adds support for rendering onto enlarged per logical
monitor framebuffers, using the scaled clutter stage views, for HiDPI
enabled logical monitors.

This works by scaling the mode of the monitors in a logical monitors by
the scale, no longer relying on scaling the window actors and window
geometry for making windows have the correct size on HiDPI monitors.

It is disabled by default, as in automatically created configurations
will still use the old mode. This is partly because Xwayland clients
will not yet work good enough to make it feasible.

To enable, add the 'scale-monitor-framebuffer' keyword to the
org.gnome.mutter.experimental-features gsettings array.

It is still possible to specify the mode via the new D-Bus API, which
has been adapted.

The adaptations to the D-Bus API means the caller need to be aware of
how to position logical monitors on the stage grid. This depends on the
'layout-mode' property that is used (see the DisplayConfig D-Bus
documentation).

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Carlos Garnacho
efae039ad9 backends: Refactor MetaScreenDirection guessing into separate function
Make it a helper MetaLogicalMonitor API, and use it on the
MetaMonitorManager.

https://bugzilla.gnome.org/show_bug.cgi?id=778119
2017-03-27 12:57:56 +02:00
Jonas Ådahl
615587cd06 monitor-manager: Split logical monitor creation
Split up logical monitor cration into derived (when derived from
current underlying configuration) and non-derived (when creating from a
logical monitor configuration). This avoids that type of logic in the
logical monitor creation function.

https://bugzilla.gnome.org/show_bug.cgi?id=779745
2017-03-09 10:17:30 +08:00
Jonas Ådahl
0b4d80d74f wayland/output: Operate on monitors instead of outputs
Operate on MetaMonitor's instead of MetaOutput's, as the latter may be
only a subset of an actual "monitor" when referring to the physical
computer equipment.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
0a0c49af71 logical-monitor: Remove outdated comment
Remove the comment about tiling things being calculated. It doesn't add
anything valuable, and tiling is hidden behind MetaMonitor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
3c6d688c87 logical-monitor: Don't mirror refresh rate
Let the callers figure out how to associate a logical monitor with a
refresh rate, instead of exposing an arbitrary one.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
5d66a13397 logical-monitor: Don't mirror physical dimensions
Don't try to mirror the physical dimension, since that's a property of
one of the monitors, not of the logical monitor. Callers are changed to
deal with choosing the monitor to represent the logical monitor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
ff633f295e logical-monitor: Don't duplicate output list
Just use the monitor list and the output lists of each monitor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
78799e58d2 monitor-manager: Make tiled Xrandr monitors based on monitors
Don't deal with adding/removing tiled Xrandr monitors in the generic
backend, but leave it to the Xrandr backend. The tiled monitor will
itself notify the backend when such a monitor is added and removed.

Tiled Xrandr monitors are now based no MetaMonitor instead of
MetaLogicalMonitor. This means that mirrored tiled monitors will now be
represented correctly.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
bf8b4e9927 monitor-manager: Generate logical monitors from monitors
Instead of using crtcs and outputs to generate logical monitors, use
the ready made monitor abstraction that hides irrelevant things such as
monitor tiling etc.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
4e812410cc monitor-manager: Move logical monitor into its own file
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00