Only ACTIVE or ACTIVATING connections are important when deciding
what icon to show, don't fallback on any, possibly invalid or deactivating,
active connection object.
https://bugzilla.gnome.org/show_bug.cgi?id=676285
We put these "access point objects" in "this._networks" and
"this._activeNetwork", so let's rename it. This also makes
the fact that each "access point object" can contain multiple
access points a tiny bit less confusing.
https://bugzilla.gnome.org/show_bug.cgi?id=698918
NM is now a lot smarter about dealing with automatic connections, so just
create an empty connection and pass it to it. The only places where NM
requires connection settings is where we require explicit setup: Bluetooth
DUN, WPA-Enterprise and WWAN/VPN. These cases are already handled by
gnome-control-center, where complex configuration is handled, so remove
the automatic connection management for now and just let NM handle it.
https://bugzilla.gnome.org/show_bug.cgi?id=698918
StLabel doesn't like that we set its properties after destructions,
and this would happen in currentInputSourceChanged() at the end,
when setting the ornament.
When we switch into an invalid input source we hide the panel
indicator and return early but we were not hiding the previously
active source label and its menu item dot and thus when switching
again to a third input source we would end up showing 2 overlapping
labels in the panel and the menu would have 2 entries with a dot.
https://bugzilla.gnome.org/show_bug.cgi?id=695841
SwitcherPopup relies on being able to pushModal(), setting the stage
input mode to FULLSCREEN, and then doing regular event processing on
the actor it adds to uiGroup. But MessageTray uses GrabHelper which
sets up a 'captured-event' handler on the stage and thus gets all
events itself.
This, of course, breaks the switcher if it's brought up in the message
tray so, for now, we'll just prevent it from being used there.
https://bugzilla.gnome.org/show_bug.cgi?id=693907
NMClient recently got more heavyweight, with a property holding supported
connections. As fully initializing a NMObject is a recursive operation
and requires multiple DBus calls, switch to async initalization for NMClient
and NMRemoteSettings.
https://bugzilla.gnome.org/show_bug.cgi?id=683288
LTE-only modems need to be treated as GSM/HSPA modems, as they all are 3GPP
modems and they all need the same kind of configuration (APN, user, password,
PIN...).
https://bugzilla.gnome.org/show_bug.cgi?id=688144
ModemManager >= 0.7 comes with a new DBus interface. This patch makes the shell
work with the new interface if the modem is detected as being exposed by the new
ModemManager (based on the device.udi string reported by NM).
https://bugzilla.gnome.org/show_bug.cgi?id=687359.
While we handle the case where ibus_bus_get_global_engine() returns
NULL, this case actually generates an exception we have to catch to
avoid some (harmless) console spam.
https://bugzilla.gnome.org/show_bug.cgi?id=692995
Some notifications, despite being emitted by shell code, should appear
to be from application or "separable" system components. Do that by
associating them with a notification-daemon policy.
Note that for this to look really good, empathy should rename itself
to Chat.
https://bugzilla.gnome.org/show_bug.cgi?id=685926
syncSectionTitle looks at device list for the section, to understand if
the section should be visible or not, so obviously it needs to see the
new device.
I wonder when this broke.
https://bugzilla.gnome.org/show_bug.cgi?id=692749
NM 0.9.7 is still not released even as a tarball, so fix this to work
with 0.9.6 again for now (although it doesn't do any device name
disambiguation in this case now).
https://bugzilla.gnome.org/show_bug.cgi?id=691720
If the setting is enabled, we record the last activated input source
for the currently focused window and switch to it when focusing back
that window. The Overview is considered a window for this purpose.
https://bugzilla.gnome.org/show_bug.cgi?id=691414
Calculate an icon based on our current state, not a mess of
signal emissions and callbacks. This is a preliminary basic
cleanup patch in preparation for the next one.
https://bugzilla.gnome.org/show_bug.cgi?id=690539
Instead of faking it by adding a bunch of main icons and secondary
icons to our own box, try and recreate the original button box
with the original icons.
https://bugzilla.gnome.org/show_bug.cgi?id=690589
Allow users to smoothly scroll on the volume indicator icon
to adjust the volume. Do this by simply passing the scroll
event to the slider inside the menu.
https://bugzilla.gnome.org/show_bug.cgi?id=687573
If present, InfiniBand devices show up with the ethernet devices (and
the presence of an InfiniBand connection will cause "Wired" to be
renamed to "Ethernet").
https://bugzilla.gnome.org/show_bug.cgi?id=677150
Instead of storing them globally and having an hardcoded list of
engines which are allowed to change their indicator symbol when the
InputMode property changes.
https://bugzilla.gnome.org/show_bug.cgi?id=682318
Remove section titles for ethernet and mobile broadband, and replace
them with device status items that recognize if multiple devices are
installed in the same section, and if so automatically disambiguate.
https://bugzilla.gnome.org/show_bug.cgi?id=677142
Stop pretending that VPN is a NMDevice, and split the useful bits into
a NMConnectionBased interface.
Make each connection have its own switch menu item and handle its own
status, and remove the VPN section title, which is no longer needed.
https://bugzilla.gnome.org/show_bug.cgi?id=682929
Currently the visibility of input volume is only updated when a stream
is added/removed - apparently no one noticed until now, as in the normal
user session we get away with this as long as we have some startup sound,
but this is not the case in the lock screen, so we may end up showing
input volume incorrectly.
https://bugzilla.gnome.org/show_bug.cgi?id=684611
Due to the way the IBus API works we might get property changes while
the menu is already open. In that case the separator visibility logic
doesn't work since it only applies on menu open/close. This works
around that issue.
https://bugzilla.gnome.org/show_bug.cgi?id=682314
IBus has a properties API which are basically generic knobs into the
engine which are serialized and presented in a way that allows us to
easily build actionable UI elements with them.
Instead of implementing the whole generic system and accepting
everything coming out of the engines, for now, this patch just adds
support for a couple of important IBus Anthy properties.
https://bugzilla.gnome.org/show_bug.cgi?id=682314
The selector for insensitive popup menu items was wrong (a PopupMenuItem is
a ShellGenericContainer, not a StButton). Fixing it showed that previous
:insensitive tracking was manual for a reason: we have many items that are
not reactive, but don't want the insensitive styling (for example those in
the battery menu).
Fix it by adding a new style-class, popup-inactive-menu-item, that is added
to all new PopupMenuItems that are not activatable.
https://bugzilla.gnome.org/show_bug.cgi?id=683988
Previously we would only read the default sink and default source when
the connection to PulseAudio succeded. This worked because all VolumeMenu
users where initialized synchronously during shell load.
With the recent session mode changes though, the lock screen menu is
created on demand, and when it loads PA is already connected, so
it doesn't update the sliders.
https://bugzilla.gnome.org/show_bug.cgi?id=683156
Since we eventually want to add a system for changing the top panel
contents depending on the current state of the shell, let's use the
"session mode" feature for this, and add a mechanism for updating the
session mode at runtime. Add support for every key besides the two
functional keys, and make all the components update automatically when the
session mode is changed. Add a new lock-screen mode, and make the lock
screen change to this when locked.
https://bugzilla.gnome.org/show_bug.cgi?id=683156
Previously, when toggling a switch on we tried to replicate NM policy and
find a good connection to activate. This is broken in many situations.
Instead, only activate something when we can be sure it's what the user
wants (i.e. when there is only one connection, or when there is none,
and thus connecting will trigger the config dialog)
https://bugzilla.gnome.org/show_bug.cgi?id=683136
The design has a combined volume-network-power indicator in the lock
screen, which when opened shows a volume slider. Implement it by abstracting
the volume menu into a PopupMenuSection, and by creating three StIcons
bound to the real ones.
https://bugzilla.gnome.org/show_bug.cgi?id=682540