Previously, when toggling a switch on we tried to replicate NM policy and
find a good connection to activate. This is broken in many situations.
Instead, only activate something when we can be sure it's what the user
wants (i.e. when there is only one connection, or when there is none,
and thus connecting will trigger the config dialog)
https://bugzilla.gnome.org/show_bug.cgi?id=683136
In multi-monitor setups, the screen might extend below the edge of
the monitor that holds the tray. In that case the tray is currently
triggered from a secondary monitor, which is rather surprising;
change the check to use the correct monitor geometry instead.
https://bugzilla.gnome.org/show_bug.cgi?id=683044
PopupMenuBase relies on open-state-changed to update the separator
visibility, but PopupMenuSection were only emitting when the parent
closed, so the first time the menu was opened, separator visiblity was
wrong.
https://bugzilla.gnome.org/show_bug.cgi?id=682998
The design has a combined volume-network-power indicator in the lock
screen, which when opened shows a volume slider. Implement it by abstracting
the volume menu into a PopupMenuSection, and by creating three StIcons
bound to the real ones.
https://bugzilla.gnome.org/show_bug.cgi?id=682540
The height of an unexpanded notification could include expanded
content if the notification has extra widgets (like actions and images),
so tweening to that cause it to expand visually.
Instead, use the height of the message tray before the restyle
as an upper bound.
https://bugzilla.gnome.org/show_bug.cgi?id=682738
Commit 22eea750 made info messages show up in the lock screen, but
as setShowWhenLocked() throws an exception when called on non-transient
notifications, the transient hint has to be set first.
https://bugzilla.gnome.org/show_bug.cgi?id=682268
Bumping overrides any animation, and causes the installed onComplete
not to run, which in turn breaks suspending from the user menu (as
it listens to lock-screen-shown).
Add a state variable (using an enumeration shared with messageTray)
to control the lock screen, and only bump when the lock is still.
https://bugzilla.gnome.org/show_bug.cgi?id=682746
Showing the removable devices is potentially a security risk (as
they include network shares). Also, a nautilus launched from there
can't be used, so it's just a way to overload the system.
https://bugzilla.gnome.org/show_bug.cgi?id=681143
This makes the workspace indicator respect the "padding" style attribute.
Also, since we no longer draw the border on top of the thumbnail,
we need to be pixel-precise in allocating the indicator height.
We use this to make the workspace selector more similar to the mockup.
https://bugzilla.gnome.org/show_bug.cgi?id=662087
If the user has the mouse down - for example when they are selecting
text and dragging - then the attempt to get a modal grab will fail.
grabHelper: allow the .grab() function to fail and do nothing in this
modal case if the grab fails.
messageTray: handle grab failure and don't pop up the tray. Change the
logic for tray dwelling so that we only try to pop up the tray once
while the pointer is in the dwell area - this avoids the possiility
that the tray will pop up once the user releases the mouse.
https://bugzilla.gnome.org/show_bug.cgi?id=682385
Currently we load all search providers from XDG_DATA_DIRS, so if
the same provider is installed several times in different directories,
we happily show duplicate results. To fix, keep track of all remote
providers we add and skip those that already have been loaded from a
different directory.
https://bugzilla.gnome.org/show_bug.cgi?id=682470
The app menu is hidden when entering the lock screen, however it
might be shown again while the lock is still in place - we don't
want this ever to be the case, so make show() a no-op while the
screen is locked.
https://bugzilla.gnome.org/show_bug.cgi?id=682475
AutorunManager relied on AutomountManager to find if the session
was active, and this broke when this stopped exporting a public
method for it. Fix AutorunManager to have its own reference to
the LoginManager.
https://bugzilla.gnome.org/show_bug.cgi?id=682455
Currently we animate scrolling to the active workspace both when
the number of workspaces changed and after changing the active
workspace. So in case we don't actually change workspace, this
results in an unnecessary animation that may even have unwanted
side effects: when done during the overview transition (e.g. in
the case of opening and activating a window on an empty workspace),
non-active workspaces become visible during the transition.
To fix, don't scroll to the active workspace when the number of
workspaces changes and rely on the 'switch-workspace' signal being
emitted as necessary.
https://bugzilla.gnome.org/show_bug.cgi?id=682002
Since dwell at the bottom of the screen is now the primary way of
summoning the tray, removing the hot corner to avoid having two
separate things that can be accidentally triggered.
https://bugzilla.gnome.org/show_bug.cgi?id=682310
Don't log a warning if an unrecognized device type is seen.
Don't show slave connections in the menu. (Eg, don't show the
individual wired connections making up a bond, since they can't be
used individually.)
Make the icon only reflect the status of connections that are visible
in the menu. (ie, don't show the "connecting" icon when an
unrecognized connection type is connecting, and don't show a
"connected" status if the only active connections are of unrecognized
types.)
https://bugzilla.gnome.org/show_bug.cgi?id=682364