Commit Graph

46 Commits

Author SHA1 Message Date
Jonas Ådahl
1f657d2c81 monitor-manager: Always set the monitor info scale
https://bugzilla.gnome.org/show_bug.cgi?id=769505
2016-08-12 14:58:39 +08:00
Jonas Ådahl
d7b87799c8 backend: Ensure the backend gets notified of monitor state having changed
Being a listener to a signal, it is inconvenient to enforce order of
execution between different signal listeners. If there are things in
the backend that should be updated before various other signal
handlers, make sure so is done by emitting the signal after having
explicitly notified the backend.

https://bugzilla.gnome.org/show_bug.cgi?id=768976
2016-07-20 14:23:48 +08:00
Rui Matos
1141929bc5 backends: Add flags to MetaMonitorMode
And export them in the DBus API since they're useful for
gnome-control-center.

https://bugzilla.gnome.org/show_bug.cgi?id=763832
2016-05-13 18:44:45 +02:00
Florian Müllner
ed5c3b39ee monitor-manager: Add get_is_builtin_display_on()
Wrap the existing laptop_display_is_on() method in a public function
that gnome-shell can use to query whether a builtin output is present
and enabled.

https://bugzilla.gnome.org/show_bug.cgi?id=765267
2016-04-21 21:16:16 +02:00
Florian Müllner
b6f11fa8b8 monitor-config: Update laptop heuristics to match GnomeRROutput
gnome-desktop's GnomeRROutput class has heuristics to classify a display
as builtin similar to our own[0]. The two heuristics don't quite match
though, so different core components can end up with a different view
on the current display configuration. Minimize that risk by adding a
couple of rules that bring the two heuristics closer together.

[0] https://git.gnome.org/browse/gnome-desktop/tree/libgnome-desktop/gnome-rr.c#n1674

https://bugzilla.gnome.org/show_bug.cgi?id=765267
2016-04-21 17:36:22 +02:00
Florian Müllner
ab6c008e3e monitor-manager: Expose output_is_laptop() method
We currently duplicate the heuristics of whether an output is considered
a laptop or not. Avoid this by sharing a small helper method.

https://bugzilla.gnome.org/show_bug.cgi?id=765267
2016-04-21 17:36:22 +02:00
Rui Matos
82bdd1e353 monitor-manager: Fix the max potential number of logical monitors
The max potential number of logical monitors (i.e. MetaMonitorInfos)
is the number of CRTCs, not the number of outputs.

In cases where we have more enabled CRTCs than connected outputs we
would end up appending more MetaMonitorInfos to the GArray than the
size it was initialized with which means the array would get
re-allocated rendering invalid some MetaCRTC->logical_monitor pointers
assigned previously and thus ending in crashes later on.

https://bugzilla.gnome.org/show_bug.cgi?id=751638
2015-11-29 19:15:37 +01:00
Rui Matos
bff75b64be monitor-manager: Expose a few helpers to clear structs
These are useful for child classes to unwind cleanly when constructing
their structures.

https://bugzilla.gnome.org/show_bug.cgi?id=756796
2015-10-30 17:47:00 +01:00
Florian Müllner
67d3a7a2d7 meta-monitor-manager: Remove bogus condition from check
An unsigned number is never smaller than 0, so we don't have to
check for it.
2015-09-24 03:08:23 +02:00
Rui Matos
2fb8da0d5a backends/monitor-manager: Validate EDID strings
Some monitors return a bunch of bytes on their display descriptor
which aren't valid utf8 and thus we fail to serialize them later on
for the DisplayConfig DBus API.

Let's fall back to the stringified product code and serial number in
that case.

https://bugzilla.gnome.org/show_bug.cgi?id=752673
2015-07-21 16:42:53 +02:00
Jonas Ådahl
441efd17ce MetaMonitorInfo: Provide scale information
Tracking back from the monitor to the output every time we need to
figure out the scale of a window on a monitor is inconvenient, so
propagate the scale from the output to the monitor it is associated
with.

https://bugzilla.gnome.org/show_bug.cgi?id=744934
2015-07-16 11:53:40 +08:00
Cosimo Cecchi
94bce5a00f monitor-manager: add a property to discover if underscan is supported
So that clients such as the control center can decide to hide an
underscanning checkbutton when the output does not support it.

Support in the KMS / native backend to come later...
2015-07-01 18:20:57 -07:00
Dave Airlie
9f65edd4f5 backend/x11: add support for setting randr 1.5 monitors
This interface allows us to propogate back the constructed
monitors to randr using the randr 1.5 protocol. Apps
should pick it up from there.
2015-06-01 09:38:13 -07:00
Dave Airlie
ea2496c80a monitors: construct tiled monitors info
The monitors info structure is created from the tiled outputs
and this is used as the central storage for info about a monitor
as opposed to the output state.

It appears at least the EDID mm w/h is for the whole monitor and
not per tile.
2015-06-01 09:38:13 -07:00
Dave Airlie
2a8563ab23 monitors: adds expose tile info as a property over dbus interface
This just adds 8 uint32s as a property to the dbus protocol.

This will be used by gnome-desktop to get the tile info.
2015-06-01 09:38:13 -07:00
Jasper St. Pierre
4d80a4cc31 Use more g_autofoo throughout mutter 2015-05-29 17:18:35 -07:00
Jasper St. Pierre
48bf807430 monitor-manager-kms: Add support for underscan 2015-04-27 17:58:38 -07:00
Tomeu Vizoso
cc53d48fa8 MonitorManager: Add support for overscan compensation
Some DRM drivers have added a consistent set of properties that
allow compensating for the overscan that some TVs do, without the
user being able to disable.
2015-04-27 17:17:15 -07:00
Carlos Garnacho
8188cddcf7 backends: Add meta_monitor_manager_get_monitor_at_point()
This function returns the monitor_info index corresponding to the given
coordinates, or -1 if none is found at that point. The native backend
has been changed in places where it could make use of this function.

https://bugzilla.gnome.org/show_bug.cgi?id=746896
2015-03-30 14:00:31 +02:00
Rui Matos
7f19db1f7b monitor-manager: Expose a method to get a monitor from an output
This method will be used by gnome-shell to resolve an output ID
(exposed from the org.gnome.Mutter.DisplayConfig DBus API) to a
logical monitor.

https://bugzilla.gnome.org/show_bug.cgi?id=743745
2015-01-30 13:13:49 -05:00
Rui Matos
3f2d658f20 monitor-manager: Expose MetaMonitorManager to introspection
This just exposes the type and the singleton getter necessary to make
it available to introspection. We'll expose more functionality as it
becomes needed.

https://bugzilla.gnome.org/show_bug.cgi?id=743745
2015-01-30 13:13:49 -05:00
Rui Matos
ad90b7dd2f monitor-manager: Initialize MetaOutput even when we can't get the EDID
Otherwise we'll crash later when building a MetaConfiguration.

https://bugzilla.gnome.org/show_bug.cgi?id=743412
2015-01-27 14:42:45 +01:00
Carlos Garnacho
71c4138933 monitor-manager: Add method to find an output matrix
This will be useful to determine input device matrices for touchscreens
and tablets.

https://bugzilla.gnome.org/show_bug.cgi?id=739397
2015-01-18 13:32:28 -08:00
Carlos Garnacho
625d3de2ee backends: Make KMS EDID information equal to X11's
EDID parsing has been refactored to a common meta_output_parse_edid()
function, which ensures the extracted information is the same on both KMS
and X11 backend, so it can be used consistently on eg. settings values.

https://bugzilla.gnome.org/show_bug.cgi?id=742882
2015-01-14 12:16:18 +01:00
Jasper St. Pierre
c5940580ed monitor-manager: Use connector_type instead of name sniffing 2014-12-29 17:15:23 -08:00
Jasper St. Pierre
d514e8ab41 monitor-manager: Add a connector-type property
This is so gnome-settings-daemon
2014-12-29 16:30:54 -08:00
Rui Matos
b63413e5b0 Revert "monitor-manager: Remove needless code"
It turns out that this was wrong because MetaWindow->monitor points to
the old monitor infos and they are needed to position windows in the
new configuration which happens in a monitors-changed handler.

This reverts commit e1704acda4.
2014-10-23 16:38:26 +02:00
Rui Matos
e1704acda4 monitor-manager: Remove needless code
Nothing uses this. Signal handlers have access to the new monitor
infos built by make_logical_config() .

https://bugzilla.gnome.org/show_bug.cgi?id=738630
2014-10-16 20:39:16 +02:00
Jasper St. Pierre
cc8462969d monitor-manager: Put the common hotplug code in a common path as well
So we can reuse it in the KMS backend.
2014-10-14 13:56:48 -07:00
Jasper St. Pierre
989bb6ebb1 monitor-manager: Simplify reading the current configuration
Make a wrapper in MetaMonitorManager that handles freeing the existing
configuration for us.
2014-10-14 13:56:48 -07:00
Jasper St. Pierre
f3595ebd08 monitor-manager: Make sure to emit PropertiesChanged for PowerSaveMode
We overrode the property for PowerSaveMode, which meant that gdbus's
auto-generated PropertiesChanged code wasn't being run.

This really confused gnome-rr and gnome-settings-daemon's power plugin
about the current DPMS state of the display, since they used their
cached PowerSaveMode properties, and never saw a PropertiesChanged being
emitted.

If a display was on, they set it to off, and then set it back on, the
setting back on would never fire, since they thought the display was
already off.

To fix this, remove our custom property override and just respond to
notifications on the object.

Namely, this fixes the DPMS management when receiving notifications so
that it now properly times out.
2014-09-25 20:17:53 -06:00
Rui Matos
7d54631ebf backends: Make MetaBackend available to introspection
This moves meta-backend.h under meta/ and, for now, just exposes to
introspection the methods that we actually need in gnome-shell.

https://bugzilla.gnome.org/show_bug.cgi?id=734301
2014-08-07 11:31:59 +02:00
Jasper St. Pierre
eb952819c2 monitor: Don't use wl_output_transform in our APIs
Invent our own API so we can build without Wayland headers.
2014-07-13 11:35:01 -04:00
Jasper St. Pierre
af135c0b0b monitor-manager: Rename output_id to winsys_id
The output_id is more of an opaque identifier for the monitor, based on
its underlying ID from the windowing system. Since we also use the term
"output_id" for the output's index, rename our use of the opaque cookie
"output_id" to "winsys_id".
2014-07-01 13:24:34 -04:00
Jasper St. Pierre
110c79d10e monitor-manager: Rename output_id to output_index
The term "output_id" is already used as an opaque ID.
2014-07-01 13:01:02 -04:00
Jasper St. Pierre
b9d867cb86 monitor-manager: Remove duplicate variable definition 2014-07-01 13:00:57 -04:00
Jasper St. Pierre
25a16c3379 Remove trailing whitespace 2014-05-02 09:34:48 -04:00
Jasper St. Pierre
1dc8a7eca3 monitor: Remove handle_xevent as a generic method 2014-04-23 12:15:12 -04:00
Jasper St. Pierre
c44b1d730d backends: Move MonitorManager creation to MetaBackend as well 2014-04-21 20:25:21 -04:00
Jasper St. Pierre
2d6bcf3885 monitor-manager: Remove debugging META_DEBUG_MULTIMONITOR hook
It's outdated and incorrect: META_TYPE_MONITOR_MANAGER is now an
abstract class.
2014-04-21 20:25:20 -04:00
Bastien Nocera
d53e04f4c8 Name all timeouts and idles
Better names can be used once we make more use of them.

https://bugzilla.gnome.org/show_bug.cgi?id=727979
2014-04-10 18:59:46 +02:00
Giovanni Campagna
42f267bb50 MonitorManager: make sure to pass the right sizes to vararg functions
A gulong is not enough to get 64 bits in all arches, so we must
cast it, or we can corrupt the stack.

This was downstream bug bugzilla.redhat.com/show_bug.cgi?id=1002055

https://bugzilla.gnome.org/show_bug.cgi?id=707267
2014-04-09 12:14:26 -07:00
Jasper St. Pierre
899d4d8477 monitor-manager: Move default get_edid_file / read_edid to base class
These are also used by the native manager.
2014-04-01 10:24:34 -04:00
Jasper St. Pierre
bce1d5117b Start creating different subdirectories for each backend 2014-03-31 23:44:47 -04:00
Jasper St. Pierre
fd392cc1e7 Remove "xrandr" from the name of the generated DBus files
It's about generic display config, not XRandR specifically.
2014-03-31 23:44:47 -04:00
Jasper St. Pierre
229360b248 Start molding out a new src/backends/ dir
Right now this just has all of the files in one directory. We'll
be introducing more structure to this in the future, and build
a proper backend system.
2014-03-31 22:11:00 -04:00