Commit Graph

148 Commits

Author SHA1 Message Date
Armin Krezović
d79ffd3976 Move UI and key grabs to MetaX11Display
https://bugzilla.gnome.org/show_bug.cgi?id=759538
2018-07-06 19:47:16 +02:00
Armin Krezović
e1c67a1824 Move monitor management API to MetaDisplay
This includes changing various users to use MetaDisplay directly, who
used MetaScreen only for this before.

https://bugzilla.gnome.org/show_bug.cgi?id=759538
2018-07-06 19:47:16 +02:00
Armin Krezović
98d912ba5f Move stack tracking and guard_window outside of MetaScreen
Move stack, stack_tracker to MetaDisplay guard_window to MetaX11Display

https://bugzilla.gnome.org/show_bug.cgi?id=759538
2018-07-06 19:47:16 +02:00
Armin Krezović
722c975aca Move alarm and xids management to MetaX11Display
https://bugzilla.gnome.org/show_bug.cgi?id=759538
2018-07-06 19:47:16 +02:00
Armin Krezović
18779109de Start populating MetaX11Display
- Moved xdisplay, name and various atoms from MetaDisplay
- Moved xroot, screen_name, default_depth and default_xvisual
  from MetaScreen

- Moved some X11 specific functions from screen.c and display.c
  to meta-x11-display.c

https://bugzilla.gnome.org/show_bug.cgi?id=759538
2018-07-06 19:47:16 +02:00
Jonas Ådahl
6621a9b5a0 tests: Add missing monitors config XML file
Lid switch test, but lid-switch.xml was not added, making it fail due to
theh file not being found.
2018-07-04 10:07:30 +00:00
Jonas Ådahl
1200182d70 backends: Move MetaOutput::crtc field into private struct
No functional changes. This is only done so that changes to reference
counting can done more reliably.

https://bugzilla.gnome.org/show_bug.cgi?id=786929
2018-06-28 13:42:15 +02:00
Hans de Goede
5eacdf7af7 monitor-unit-tests: Add non upright panel test
https://bugzilla.gnome.org/show_bug.cgi?id=782294
2017-12-25 17:01:45 +08:00
Hans de Goede
ca638d1354 monitor-unit-tests: Add support for panel-orientation
https://bugzilla.gnome.org/show_bug.cgi?id=782294
2017-12-25 17:01:45 +08:00
Jonas Ådahl
fc713ecb70 monitor-unit-tests: Check config loading on lid switches
Check that we apply the correct stored configuration when the lid is
opend and closed while an external monitor is connected.

https://bugzilla.gnome.org/show_bug.cgi?id=788915
2017-11-30 11:48:44 +08:00
Jonas Ådahl
500c13ab6f monitor-unit-tests: Always reset CRTC transform ability
Changing the test monitor managers ability to rotate CRTCs in one test
affected the next test. Avoid leaking such state by resetting it before
each test. To continue passing, some tests needed to be updated
regarding to still pass.

https://bugzilla.gnome.org/show_bug.cgi?id=788915
2017-11-30 11:48:44 +08:00
Jonas Ådahl
050267fe74 monitor-unit-tests: Add test for lid toggle after hot unplug
https://bugzilla.gnome.org/show_bug.cgi?id=788915
2017-11-30 11:48:44 +08:00
Jonas Ådahl
ce25a0171c monitor-unit-tests: Add test for lid closed after hot plug
Add a test case that checks that we don't try to revert to a
laptop-panel-only configuration after closing the lid after an external
monitor is connected.

https://bugzilla.gnome.org/show_bug.cgi?id=788915
2017-11-30 11:48:44 +08:00
Jonas Ådahl
12381d57d1 monitor-unit-tests: Check non-first preferred modes
Check that if there are multiple modes with the same ID (resolution,
refresh rate and handled flags) we correctly add the preferred mode to
the list of monitor modes.

https://bugzilla.gnome.org/show_bug.cgi?id=789153
2017-10-19 10:17:14 +08:00
Jonas Ådahl
76096a725b monitor-unit-tests: Check going headless -> headless
https://bugzilla.gnome.org/show_bug.cgi?id=788607
2017-10-07 00:36:03 -04:00
Jonas Ådahl
c1683073f1 backends: Split out CRTC/output management to MetaGpu
In order to eventually support multilpe GPUs with their own connectors,
split out related meta data management (i.e. outputs, CRTCs and CRTC
modes) into a new MetaGpu GObject.

The Xrandr backend always assumes there is always only a single "GPU" as
the GPU is abstracted by the X server; only the native backend (aside
from the test backend) will eventually see more than one GPU.

The Xrandr backend still moves some management to MetaGpuXrandr, in
order to behave more similarly to the KMS counterparts.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 18:05:20 -04:00
Jonas Ådahl
315a6f43d7 monitor-manager: Keep pointer to backend
Instead of accessing the global singleton, keep a pointer to the
backend in the MetaMonitorManager struct.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
16a6aef5a7 backends/native: Move KMS fd management to monitor manager
Move finding, opening and managment of the KMS file descriptor to
MetaMonitorManagerKms. This means that the monitor manager creation can
now fail, both if more than one GPU with connectors is discovered, or
if finding or opening the primary GPU fails.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
cfee58798e backends/crtc: Keep a pointer to the monitor manager
Instead of passing it around or fetching the singleton, keep a pointer
to the monitor manager that owns the CRTC. This will eventually be
replaced with a per GPU/graphics card object.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
e0d839aea2 backends/output: Keep a pointer to the monitor manager
Instead of passing it around or fetching the singleton, keep a pointer
to the monitor manager that owns the output. This will eventually be
replaced with a per GPU/graphics card object.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
2db5505216 monitor-manager: Turn MetaCrtcMode into a GObject
Convert MetaCrtcMode from a plain struct to a GObject. This changes the
storage format, and also the API, as the API was dependent on the
storage format.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
f64fab1d2d monitor-manager: Make MetaCrtc a GObject
Turn MetaCrtc into a GObject and move it to a separate file. This
changes the storage format, resulting in changing the API for accessing
MetaCrtcs from using an array, to using a GList.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
9817a6aa47 Make MetaOutput a GObject
Turn MetaOutput into a GObject and move it to a separate file. This
changes the storage format, resulting in changing the API for accessing
MetaOutputs from using an array, to using a GList.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
120db06c60 monitor-tests: Test config migration with refresh rate wiggle room
Check that we finish configurations within range, and discard the ones
out of range.

https://bugzilla.gnome.org/show_bug.cgi?id=787668
2017-10-04 09:45:52 -04:00
Jonas Ådahl
e76ab05d45 monitor-tests: Fix error message grammar mistake 2017-10-04 09:45:02 -04:00
Jonas Ådahl
99e1cd549d monitor-unit-tests: Test configs with explicitly disabled monitors
Check that configurations where monitors are disabled are properly
used. Also test that old configurations with explicitly disabled
outputs are migrated properly.

https://bugzilla.gnome.org/show_bug.cgi?id=787629
2017-10-02 15:34:41 -04:00
Jonas Ådahl
efdbeb7c1b monitor-unit-tests: Add way for test case setup to specify output serial
This is needed to avoid migration tests to avoid the best-effort tiling
monitor detection paths.

https://bugzilla.gnome.org/show_bug.cgi?id=787629
2017-10-02 15:34:41 -04:00
Jonas Ådahl
22cdc8f414 monitor-manager: Pass config to derive from when updating state
When we update state, we might not have set the current config yet (for
example if the Xrandr assignment didn't change), so pass the monitors
config we should derive from instead of fetching it from the monitor
config manager.

https://bugzilla.gnome.org/show_bug.cgi?id=787477
2017-09-20 17:26:32 +08:00
Jonas Ådahl
e2d904c32b tests/monitor-unit-tests: Run a client while testing
Run a client while testing and check that it's alive when checking each
monitor configuration.

https://bugzilla.gnome.org/show_bug.cgi?id=730551
2017-08-30 13:44:05 +08:00
Jonas Ådahl
fa9c09feee tests/monitor-unit-tests: Sleep some after each hot plug
Give clients (such as Xwayland) a chance to bind the wl_output global
before we continue, otherwise there is an significant risk that mutter
won't see the bind request until after the next hot plug which might
have destroyed the global object.

https://bugzilla.gnome.org/show_bug.cgi?id=730551
2017-08-30 13:44:05 +08:00
Jonas Ådahl
3f6a2d02fd tests: Add headless start test case
Test that mutter starts properly when there are no monitors connected
yet, and that things work when a monitor is eventually connected.

https://bugzilla.gnome.org/show_bug.cgi?id=730551
2017-08-30 13:44:05 +08:00
Jonas Ådahl
5b37901b57 tests/utils: Add test_client_quit() helper
https://bugzilla.gnome.org/show_bug.cgi?id=730551
2017-08-30 13:44:05 +08:00
Jonas Ådahl
522eec00cd monitor: Add foreach output helper and fix foreach crtc helper
The foreach CRTC monitor mode helper incorrectly iterated over outputs
without CRTC when non-tiled modes were set on tiled monitors. This was
not expected by callers, so fix the helper to only iterate over active
outputs (that has or should have a CRTC).

The test cases uses the incorrect behaviour of the foreach CRTC helper
to check that the disabled outputs mode are set to NULL, so add a
foreach output helper and change the tests to use that instead.

https://bugzilla.gnome.org/show_bug.cgi?id=730551
2017-08-30 13:09:38 +08:00
Jonas Ådahl
be11c32815 tests: Move out test client helper from test-runner.c
It could be useful for running other types of test clients in other
tests.

https://bugzilla.gnome.org/show_bug.cgi?id=730551
2017-08-30 13:09:38 +08:00
Jonas Ådahl
0aa7405a2a monitor-manager: Fall back to minimum screen size of 640 x 480
When headless, we don't have any logical monitors to derive a screen
size from, but we can't set it to empty as that will cause issues with
the clutter stage, UI widget layout and other things. To avoid such
issues, just fall back to a 640 x 480 screen size when headless.

https://bugzilla.gnome.org/show_bug.cgi?id=730551
2017-08-30 13:09:38 +08:00
Jonas Ådahl
35c9280fb6 monitor-manager: Try to restore previous config before regenerating
When opening a laptop lid, one will likely want to restore the
configuration one had prior to closing it, so when ensuring monitor
configuration, first try to see if the previously set configuration is
both complete (all connected monitors are configured) and applicable
(it is a valid configuration) and only try to generate a new from
scratch if that failed.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
8b92ad1d4b tests/monitor-unit-tests: Clear config history before each test
To not let different tests interfere with each other, clear the config
history before each run.
2017-08-21 12:23:51 +08:00
Jonas Ådahl
0d6e3fd675 tests/monitor-unit-tests: Use special purpose add test helper
Will later be used to set a setup function.
2017-08-21 12:23:51 +08:00
Jonas Ådahl
6c0f107db0 tests: Add rotated multi head monitor config migration test
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
61950755ec tests: Add monitor config migration tests
So far some basic testing, including:

 * Test that the migrated configuration is applicable
 * Test that a monitors.xml with multiple configurations are translated
 * Test rotation
 * Test tiled monitor discovery (well, test a made up tiled monitor
   configuration since I don't have a real one)

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
bc3162460f Migrate old monitor configuration files to new system
This commit changes the new configuration system to use monitors.xml
instead of monitors-experimental.xml. When starting up and the
monitors.xml file is loaded, if a legacy monitors.xml file is
discovered (it has the version number 1), an attempt is made to migrate
the stored configuration onto the new system.

This is done in two steps:

1) Parsing and translation of the old configuration. This works by
parsing file using the mostly the old parser, but then translating the
resulting configuration structs into the new configuration system. As
the legacy configuration system doesn't carry over some state (such as
tiling and scale used), some things are not available. For tiling, the
migration paths makes an attempt to discover tiled monitors by
comparing EDID data, and guessing what the main tile is. Determination
of the scale of a migrated configuration is postponed until the
configuration is actually applied. This works by flagging the
configuration as 'migrated'.

2) Finishing the migration when applying. When a configuration with the
'migrated' flag is retrieved from the configuration store, the final
step of the migration is taken place. This involves calculating the
preferred scale given the mode configured, while making sure this
doesn't result in any overlapping logical monitor regions etc.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
e8a62861c9 Remove old monitor configuration system
Remove the old MetaMonitorConfig system and mark the new one as
non-experimental. This also removes the D-Bus property.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:20:53 +08:00
Jonas Ådahl
2bdd97e067 monitor-unit-tests: Check tiled monitors with non-origin main output
Test that a tiled monitor with tile (0, 0) as the non-main output,
where main output is defined as the output that is active as long as
the monitor is active.

https://bugzilla.gnome.org/show_bug.cgi?id=781723
2017-07-19 17:06:17 +08:00
Jonas Ådahl
4cc5b25493 tests: Add test for setting an interlaced monitor mode
https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
49c5228655 DisplayConfig: Add support for interlaced modes
Differentiate between non-interlaced and interlaced modes. This is done
by appending an "i" after the resolution part of the mode ID, and
adding a 'is-interlaced' (b) property to the mode properties.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
85638c1b19 tests: Check expected monitor mode count
https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
2507e53d04 tests: Test monitor mode refresh rate
Check that the monitor refresh rate corresponds to the CRTC mode
refresh rate.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
a9c1c6d9fb Fix a couple of wrong indentations
https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
e42206cc43 tests: Add non-precise fractional scaling test
https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
b2a530b326 DisplayConfig: Make supported scales per mode
This changes the API to pass supported scales per mode instead of
providing a global list. This allows for more flexible scaling
scenarious, where a scale compatible with one mode can still be made
available even though another mode is incompatible.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00