Commit Graph

95 Commits

Author SHA1 Message Date
Carlos Garnacho
bbcd65ce38 backends: Hook ClutterSeat::touch-mode to PanelOrientationManaged
We only want the panel autorotation to happen if the laptop has an
accelerometer, and is in tablet mode. Regular laptop mode should
lock the orientation, and let it be configured manually.

https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1311
2020-09-05 07:25:02 +00:00
Carlos Garnacho
1acf744473 backends: Centralize panel autorotation in a DisplayConfig property
Instead of having everyone check net.hadess.SensorProxy themselves, have
this all controlled by the MetaOrientationManager, and proxied everywhere
else via a readonly property in org.gnome.Mutter.DisplayConfig.

We want to attach more complex policies here, and it seems better to
centralize the handling of the autorotation feature rather than
implementing policy changes all over the place.

https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1311
2020-09-05 07:25:02 +00:00
Jonas Ådahl
b69111d8e6 monitor-manager: Rename *Info structs to *Assignment
MetaCrtcInfo and MetaOutputInfo did not represent information about
MetaCrtc and MetaOutput, but the result of the monitor configuration
assignment algorithm, thus rename it to MetaCrtcAssignment and
MetaOutputAssignment.

The purpose for this is to be able to introduce a struct that actually
carries information about the CRTCs and outputs, as retrieved from the
backend implementations.

https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1287
2020-06-10 18:54:50 +00:00
Jonas Ådahl
f71316c850 output: Move configureable state to instance private
That is is_presentation, is_primary, is_underscanning and backlight.

The first three are set during CRTC assignment as they are only valid
when active. The other is set separately, as it is untied to
monitor configuration.

https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1287
2020-06-10 18:54:50 +00:00
Jonas Ådahl
0a6034ef3a monitor-manager: Remove 'mirror' capability
With per-CRTC views, there is nothing stopping NVIDA EGLStream based
rendering to not support monitor mirroring, so lets remove that
restriction.

https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1098
2020-03-18 00:46:20 +00:00
Jonas Ådahl
fe42d56db3 crtc: Move configured state to separate struct
To make it more reliable to distinguish between values that are read
from the backend implementation (which is likely to be irrelevant for
anything but the backend implementation), split out those values (e.g.
layout).

This changes the meaning of what was MetaCrtc::rect, to a
MetaCrtcConfig::layout which is the layout the CRTC has in the global
coordinate space.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/1042
2020-02-25 18:39:51 +01:00
Olivier Fourdan
c3c6668343 monitor-manager: Add get_vendor_name API
The monitor manager keeps the list of PnP Ids, add a new API to get the
vendor name from a given PnP ID.

https://gitlab.gnome.org/GNOME/mutter/issues/645
2019-06-28 11:19:22 +02:00
Jonas Ådahl
5c500ad402 backend: Move GPU ownership from the monitor manager to the backend
Lets work towards making MetaMonitorManager about managing monitors, and
not about managing GPUs. This changes other units to keep a pointer to
the backend instead of a monitor manager, in case their ownership
changed, or their main usage of the monitor manager was to look up GPUs.

https://gitlab.gnome.org/GNOME/mutter/issues/548
https://gitlab.gnome.org/GNOME/mutter/merge_requests/525
2019-06-20 13:31:55 +00:00
Jonas Ådahl
4cae9b5b11 monitor-manager: Clean up DPMS state tracking
DPMS is configured from a bit all over the place: via D-Bus, via X11 and
when reading the current KMS state. Each of these places did it slightly
differently, directly poking at the field in MetaMonitorManager.

To make things a bit more managable, move the field into a new
MetaMonitorManagerPrivate, and add helpers to get and set the current
value. Prior to this, there were for example situations where the DPMS
setting was changed, but without signal listeners being notified about
it.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/506
2019-04-02 13:49:59 +00:00
Dariusz Gadomski
cbb2a286f2 monitor-manager: Don't use wacky physical dimensions in display name 2019-02-04 17:41:36 +01:00
Marco Trevisan (Treviño)
e02fef8e2f meta: Hide libmutter symbols by default and selectively export them
Make meson link libmutter using -fvisibility=hidden, and introduce META_EXPORT
and META_EXPORT_TEST defines to mark a symbols as visible.
The TEST version is meant to be used to flag symbols that are only used
internally by mutter tests, but that should not be considered public API.

This allows us to be more precise in selecting what is exported and what is
not, without the need of a version-script file that would be more complicated
to maintain.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/395
2019-01-23 14:18:13 +01:00
Marco Trevisan (Treviño)
e352011830 MonitorManager: Use composition instead of inheriting from dbus skeleton
MonitorManager was inheriting from MetaDBusDisplayConfigSkeleton, this was
causing introspection to see this like a GDBus skeleton object exposing to
clients methods that were not required.

Also, this required us to export meta_dbus_* symbols to the library, while
these should be actually private.

So, make MetaMonitorManager to be just a simple GObject holding a skeleton
instance, and connect to its signals reusing most of the code with just few
minor changes.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/395
2019-01-23 14:12:07 +01:00
Niels De Graef
0478c225b7 Add some gtk-doc comments. 2019-01-06 21:57:16 +01:00
Robert Mader
676a8da005 monitor-transform: Move helper functions into their own file
The existing ones are statically inlined, so there is no .c file
right now.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/366
2019-01-05 14:15:23 +01:00
Niels De Graef
49cb691bb5 monitor-manager: remove get_edid_file() vfunc
It wasn't implemented by any subclass, it's not provided by DRM either.
And even if a subclass were to have only a file available, it could read
it into a GBytes as well and just use `read_edid()`.

Found this while working on !269.
2018-11-26 14:37:54 +01:00
Jonas Ådahl
2f4a68c8c3 Clean up include macros mess
The order and way include macros were structured was chaotic, with no
real common thread between files. Try to tidy up the mess with some
common scheme, to make things look less messy.
2018-11-06 17:17:36 +01:00
Bastien Nocera
951219650f backend: Move lid-is-closed handling to MetaBackend
Rather than handle UpClient in both MetaBackend (to reset the idletime
when the lid is opened), and in MetaMonitorManager and
MetaMonitorConfigManager (to turn the screen under the lid on/off
depending on its status), move the ability to get the lid status from
UPower or mock it in one place, in MetaBackend.
2018-07-18 10:17:36 +00:00
Bastien Nocera
49b23c7490 monitor-manager: Cache the last known value of "lid-is-closed"
Restarting UPower will make every property of UpClient emit a "notify"
signal (as a GDBusProxy would). Avoid mutter reconfiguring the displays
when upower restarts by caching the last known value of "lid-is-closed"
and only reconfiguring the displays if it actually changed.

This fixes a black out of the screen when UPower restarts.
2018-07-18 10:17:35 +00:00
Armin Krezović
1d5e37050d Stop using MetaScreen where it is unnecessary
https://bugzilla.gnome.org/show_bug.cgi?id=759538
2018-07-06 19:47:16 +02:00
Armin Krezović
e1c67a1824 Move monitor management API to MetaDisplay
This includes changing various users to use MetaDisplay directly, who
used MetaScreen only for this before.

https://bugzilla.gnome.org/show_bug.cgi?id=759538
2018-07-06 19:47:16 +02:00
Hans de Goede
e59ca14f6c monitor-manager: Take panel orientation into account when getting input matrix
If a LCD panel has a non normal orientation (mounted upside-down or 90
degrees rotated) then the kernel will report touchscreen coordinates with
the origin matching the native (e.g. upside down) coordinates of the panel.

Since we transparently rotate the image on the panel to correct for the
non normal panel-orientation, we must apply the same transform to input
coordinates to keep the aligned.

https://bugzilla.gnome.org/show_bug.cgi?id=782294
2017-12-25 17:01:45 +08:00
Hans de Goede
7917b083cb monitor-manager: Take drm-connector panel-orientation property into account
Some x86 clamshell design devices use portrait tablet LCD panels while
they should use a landscape panel, resoluting in a 90 degree rotated
picture.

Newer kernels detect this and rotate the fb console in software to
compensate. These kernels also export their knowledge of the LCD panel
orientation vs the casing in a "panel orientation" drm_connector property.

This commit adds support to mutter for reading the "panel orientation"
and transparently (from a mutter consumer's pov) fixing this by applying
a (hidden) rotation transform to compensate for the panel orientation.

Related: https://bugs.freedesktop.org/show_bug.cgi?id=94894

https://bugzilla.gnome.org/show_bug.cgi?id=782294
2017-12-25 17:01:45 +08:00
Jonas Ådahl
c1683073f1 backends: Split out CRTC/output management to MetaGpu
In order to eventually support multilpe GPUs with their own connectors,
split out related meta data management (i.e. outputs, CRTCs and CRTC
modes) into a new MetaGpu GObject.

The Xrandr backend always assumes there is always only a single "GPU" as
the GPU is abstracted by the X server; only the native backend (aside
from the test backend) will eventually see more than one GPU.

The Xrandr backend still moves some management to MetaGpuXrandr, in
order to behave more similarly to the KMS counterparts.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 18:05:20 -04:00
Jonas Ådahl
315a6f43d7 monitor-manager: Keep pointer to backend
Instead of accessing the global singleton, keep a pointer to the
backend in the MetaMonitorManager struct.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
518fb9fb5e backends: Split monitor manager creation into create and setup
The monitor manager instance was created and setup in one step; at
construction. This is problematic if, in the future, the monitor manager
creation can fail, as the monitor manager is created quite late.

To make it possible to in the future fail creating a monitor manager,
create the instance very early when initiating the backend, then on
post init backend setup, "setup" the monitor manager state, i.e. read
the current state and setup the stage.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
2db5505216 monitor-manager: Turn MetaCrtcMode into a GObject
Convert MetaCrtcMode from a plain struct to a GObject. This changes the
storage format, and also the API, as the API was dependent on the
storage format.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
f64fab1d2d monitor-manager: Make MetaCrtc a GObject
Turn MetaCrtc into a GObject and move it to a separate file. This
changes the storage format, resulting in changing the API for accessing
MetaCrtcs from using an array, to using a GList.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
a62e9f99a2 backends: Remave unused meta_monitor_manager_get_resources() API 2017-10-05 16:18:43 -04:00
Jonas Ådahl
9817a6aa47 Make MetaOutput a GObject
Turn MetaOutput into a GObject and move it to a separate file. This
changes the storage format, resulting in changing the API for accessing
MetaOutputs from using an array, to using a GList.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
22cdc8f414 monitor-manager: Pass config to derive from when updating state
When we update state, we might not have set the current config yet (for
example if the Xrandr assignment didn't change), so pass the monitors
config we should derive from instead of fetching it from the monitor
config manager.

https://bugzilla.gnome.org/show_bug.cgi?id=787477
2017-09-20 17:26:32 +08:00
Jonas Ådahl
0aa7405a2a monitor-manager: Fall back to minimum screen size of 640 x 480
When headless, we don't have any logical monitors to derive a screen
size from, but we can't set it to empty as that will cause issues with
the clutter stage, UI widget layout and other things. To avoid such
issues, just fall back to a 640 x 480 screen size when headless.

https://bugzilla.gnome.org/show_bug.cgi?id=730551
2017-08-30 13:09:38 +08:00
Jonas Ådahl
3005a400ca monitor-manager: Add helper for getting monitor from connector
This will be used later.

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 11:49:01 +08:00
Jonas Ådahl
e8a62861c9 Remove old monitor configuration system
Remove the old MetaMonitorConfig system and mark the new one as
non-experimental. This also removes the D-Bus property.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:20:53 +08:00
Rui Matos
3f9c5823cb backends: Add API to switch to predetermined monitor configurations
This will allows us to support the XF86Display key present on some
laptops, directly in mutter. This is also known, in evdev, as
KEY_SWITCHVIDEOMODE.

The common usage for this key is to alternate between a few well known
multi-monitor configurations though these aren't officially
standardized. As an example, Lenovo documents it as:

"Switches the display output location between the computer display
and an external monitor."

On this patch, we're just introducing the configurations that have been
implemented in g-s-d until now, which go a bit beyond the above
description.

https://bugzilla.gnome.org/show_bug.cgi?id=781906
2017-07-19 11:18:53 +02:00
Rui Matos
7360f51ee8 meta-monitor-manager: Add API to rotate the current configuration
This will allows us to support the XF86RotateWindows key present on
some laptops directly in mutter.

https://bugzilla.gnome.org/show_bug.cgi?id=781906
2017-07-14 15:31:20 +02:00
Jonas Ådahl
49c5228655 DisplayConfig: Add support for interlaced modes
Differentiate between non-interlaced and interlaced modes. This is done
by appending an "i" after the resolution part of the mode ID, and
adding a 'is-interlaced' (b) property to the mode properties.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
b2a530b326 DisplayConfig: Make supported scales per mode
This changes the API to pass supported scales per mode instead of
providing a global list. This allows for more flexible scaling
scenarious, where a scale compatible with one mode can still be made
available even though another mode is incompatible.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
10b0351a59 Add support for rudimentary fractional scaling
When the logical layout mode is used, allow configuring the scaling to
be non-integer. Supported scales are so far hard coded to include at
most 1, 1.5 and 2, and scales that doesn't result in non-fractional
logical monitor sizes are discarded.

Wayland outputs are set to have scale ceil(actual_scale) meaning well
behaving Wayland clients will provide buffers with buffer scale 2, thus
being scaled down to the fractional scale.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
b64c69e4bc logical-monitor: Make scale a float
To support fractional scaling, the logical monitor scale must be stored
as a float. No other functional changes is part of this commit.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
1bb0e18042 monitor-manager/xrandr: Allow configuring scales on X11 too
This commit makes it possible to configure logical monitor scale also
when running on top of an X11 server using Xrandr. An extra property
'requires-globla-scale' is added to the D-Bus API is added to instruct
a configuration application to only allow setting a global logical
monitor scale.

This is needed to let gsd-xsettings use the configured state to set a
XSettings state that respects the explicit monitor configuration.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-05-26 14:31:48 +08:00
Jonas Ådahl
95d0117784 monitor-manager: Hook up config manager to display config confirmation
Make it possible to confirm or cancel the new configuration also when
the new API is used.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
0c64c35a8a monitor-manager: Make the config manager an 'experimental feature'
Instead of using a environment variable, add a new 'experimental
feature' gsetting keyword "monitor-config-manager" that enables the use
of the new MetaMonitorConfigManager. This commit also makes it possible
to switch between the two systems without restarting mutter.

The D-Bus API is disabled when the experimental feature is not enabled,
and clients trying to access it will get a access-denied error in
response. A new property 'IsExperimentalApiEnabled' is added to let the
D-Bus client know whether it is possible to use the experimental API or
not.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
8163ca6821 Add support for scaled logical monitor framebuffers
This commit adds support for rendering onto enlarged per logical
monitor framebuffers, using the scaled clutter stage views, for HiDPI
enabled logical monitors.

This works by scaling the mode of the monitors in a logical monitors by
the scale, no longer relying on scaling the window actors and window
geometry for making windows have the correct size on HiDPI monitors.

It is disabled by default, as in automatically created configurations
will still use the old mode. This is partly because Xwayland clients
will not yet work good enough to make it feasible.

To enable, add the 'scale-monitor-framebuffer' keyword to the
org.gnome.mutter.experimental-features gsettings array.

It is still possible to specify the mode via the new D-Bus API, which
has been adapted.

The adaptations to the D-Bus API means the caller need to be aware of
how to position logical monitors on the stage grid. This depends on the
'layout-mode' property that is used (see the DisplayConfig D-Bus
documentation).

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
f25f14351c monitor-manager: Make max screen size optional
Make the concept of maximum screen size optional, as it is not
necessarily a thing on all systems (e.g. when using the native backend
and stage views).

The meta_monitor_monitor_get_limits() function is replaced by a
meta_monitor_manager_get_max_screen_size() which fails when no screen
limit is available. Callers and other users of the previous max screen
size fields are updated to deal with the fact that the limit is
optional.

The new D-Bus API is changed to move it to the properties bag, where
its absence means there is no applicable limit.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
691e7951ea DisplayConfig: Add new API for configuring monitors
Add a new D-Bus API that uses the state from GetCurrentState to
configure high level monitors, instead of low level CRTCs and
connectors. So far persistent configuration is not implemented, as
writing to the configuration store is still not supported.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
d050fdb17f monitor-manager: Add per backend capabilities
Add a private API for querying backend capabilities. For now, only
mirroring capability is reported.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
9e8ee491e6 monitor-manager: Add API to get scales supported by the backend
For the Xrandr backend, only scale 1 is supported, for the others, 1
and 2 are reported as supported.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
a393a614a1 monitor-manager: Remove 'scale' from MetaOutput
Replace the 'scale' of an output with a vfunc on the MetaMonitorManager
class that takes a monitor and a monitor mode which calculates the
scale. On X11 this always returns 1, on KMS, the old formula is used.
On the dummy and test backends, the already configured values are
returned.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:46 +08:00
Jonas Ådahl
cdedd017d6 input-settings: Use logical monitors instead of outputs
A MetaOutput is a connector, not exactly a monitor or a region on the
stage; for example tiled monitors are split up into multiple outputs,
and for what is used in input settings, that makes no sense. Change
this to use logical monitors instead of outputs.

https://bugzilla.gnome.org/show_bug.cgi?id=779745
2017-03-09 10:17:30 +08:00
Jonas Ådahl
944339f6a5 monitor-manager: Expose whether the backend handles a transform
Expose via a new API whether the transform on a logical monitor is
handled by the backend. This was previously only exposed only in the
native backend. This will be used to emulate not supporting transforms
in the backend in the nested backend.

https://bugzilla.gnome.org/show_bug.cgi?id=779745
2017-03-09 10:17:30 +08:00