When opening a laptop lid, one will likely want to restore the
configuration one had prior to closing it, so when ensuring monitor
configuration, first try to see if the previously set configuration is
both complete (all connected monitors are configured) and applicable
(it is a valid configuration) and only try to generate a new from
scratch if that failed.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
So far some basic testing, including:
* Test that the migrated configuration is applicable
* Test that a monitors.xml with multiple configurations are translated
* Test rotation
* Test tiled monitor discovery (well, test a made up tiled monitor
configuration since I don't have a real one)
https://bugzilla.gnome.org/show_bug.cgi?id=777732
Test that a tiled monitor with tile (0, 0) as the non-main output,
where main output is defined as the output that is active as long as
the monitor is active.
https://bugzilla.gnome.org/show_bug.cgi?id=781723
When the logical layout mode is used, allow configuring the scaling to
be non-integer. Supported scales are so far hard coded to include at
most 1, 1.5 and 2, and scales that doesn't result in non-fractional
logical monitor sizes are discarded.
Wayland outputs are set to have scale ceil(actual_scale) meaning well
behaving Wayland clients will provide buffers with buffer scale 2, thus
being scaled down to the fractional scale.
https://bugzilla.gnome.org/show_bug.cgi?id=765011
Test that configuration works as expected when the backend doesn't
support handling the transform and an intermediate offscreen
framebuffer is used.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
In order to test deriving the logical state from the underlying
configuration, as is always done on X11, make the test backend derive
the state when stage views are disabled.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
The CRTC position depends on the transform and how the transform is
implemented. The function calculating the positions still doesn't
support anything but the non-transformed case; this commit is in
preparation of adding support for transforms.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
This commit adds support for rendering onto enlarged per logical
monitor framebuffers, using the scaled clutter stage views, for HiDPI
enabled logical monitors.
This works by scaling the mode of the monitors in a logical monitors by
the scale, no longer relying on scaling the window actors and window
geometry for making windows have the correct size on HiDPI monitors.
It is disabled by default, as in automatically created configurations
will still use the old mode. This is partly because Xwayland clients
will not yet work good enough to make it feasible.
To enable, add the 'scale-monitor-framebuffer' keyword to the
org.gnome.mutter.experimental-features gsettings array.
It is still possible to specify the mode via the new D-Bus API, which
has been adapted.
The adaptations to the D-Bus API means the caller need to be aware of
how to position logical monitors on the stage grid. This depends on the
'layout-mode' property that is used (see the DisplayConfig D-Bus
documentation).
https://bugzilla.gnome.org/show_bug.cgi?id=777732
Let the backends decide whether to just rebuild a derived state, or use
the NULL config to rebuild an empty logical state.
This also changes the expected screen size values of the no-outputs
test; as this case is actually handled now.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
Replace the 'scale' of an output with a vfunc on the MetaMonitorManager
class that takes a monitor and a monitor mode which calculates the
scale. On X11 this always returns 1, on KMS, the old formula is used.
On the dummy and test backends, the already configured values are
returned.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
Make sure that each logical monitor owns the expected actual monitors.
This currently needs special care when dealing with laptop lid the
configuration, as the MetaMonitorConfigManager path still deosn't
handle restoring the previous configuration, meaning the logical
monitor with the external monitor will continue being primary.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
This is partly redundant given that the current monitor mode is checked
against the CRTC mode, but this also checks the disabled CRTCs. Later
the configured mode position and transform will be checked.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
Check that the crtc mode has the correct intra-monitor position. In
effect, this tests that the CRTCs in a tiled monitor are configured with
the correct mode on the correct position.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
The main output of the main (first) monitor of a primary logical
monitor should have the MetaOutput::is_primary field set; all other
outputs should have it not set.
All outputs associated with a logical monitor with presentation set
should have MetaOutput::is_presentation set. No other outputs should
have it set.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
Add a flag to the test setup creation function enabling the caller to
specify whether a stored config should be used. This is done by
changing the value of the hotplug_mode_update MetaOutput field,
normally used by VMs to do the same.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
Both the monitor unit tests and monitor store unit tests will want to
check whether the config manager is used and set custom configuration
files.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
This tests only the monitor configuration and basic functionality. It
does not test anything related to window management and Wayland client
interaction.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
Use the g_assert_cmp(int|uint|...) macros when comparing integers and
unsigned integers. This means that the mismatched numbers are printed
in the test report.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
Add a test case that checks that configuration works when the lid is
initialy closed then later opened. This test case is disabled when the
legacy configuration is used as it does not handle that situation.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
The MetaMonitorMode referred to the mode of a CRTC, and with the future
introduction of a MetaMonitor, theh old name would be confusing.
Instead call it what it is.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
Set up the expected result in a declarative way in the same place as
the test case setup is declared. This way we have a completely
declarative way to create test cases.
https://bugzilla.gnome.org/show_bug.cgi?id=777732