Commit Graph

45 Commits

Author SHA1 Message Date
Jonas Ådahl
5d1eccfb6f boxes: Fix spelling in API
Change adjecent to adjacent.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/496
2019-03-17 14:12:40 +00:00
Emilio Pozuelo Monfort
6975c8b424 monitor-config-manager: respect other outputs' CRTC
We should not only take the old CRTC for an output whenever
possible, but we should also assign one that is 'free', i.e.
one that another monitor (to be processed after this one)
isn't using, so that that monitor can use the same CRTC.

https://gitlab.gnome.org/GNOME/mutter/issues/373
2019-02-21 17:23:38 +02:00
Emilio Pozuelo Monfort
f4f823f238 monitor-config-manager: reuse old CRTC when possible
We shouldn't change an output's CRTC if we don't have to, as
that causes the output to go black.

This patch depends on
"monitor-unit-tests: initial crtcs in custom_lid_switch".

https://gitlab.gnome.org/GNOME/mutter/issues/373
2019-02-21 17:23:38 +02:00
Jonas Ådahl
4786cc85bd monitor-config-manager: Round layout size after scaling
When calculating the logical monitor layout size given a scale, don't
risk precision loss by float to int casting, which could result in a too
small layout.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2018-12-05 10:34:22 +00:00
Daniel Drake
6267732bec monitor-manager: use MonitorsConfig to track switch_config
When constructing MetaMonitorsConfig objects, store which type
of switch_config they are for (or UNKNOWN if it is not such
type of config).

Stop unconditionally setting current_switch_config to UNKNOWN when
handling monitors changed events. Instead, set it to the switch_config
type stored in the MonitorsConfig in the codepath that updates logical
state. In addition to being called in the hotplug case along the same
code flow that generates monitors changed events, this is also called
in the coldplug case where a secondary monitor was connected before
mutter was started.

When creating the default linear display config, create it as a
switch_config so that internal state gets updated to represent
linear mode when this config is used.

The previous behaviour of unconditionally resetting current_switch_config
to UNKNOWN was breaking the internal state machine for display config
switching, causing misbehaviour in gnome-shell's switchMonitor UI when
using display switch hotkeys. The lack of internal tracking when the
displays are already in the default "Join Displays" linear mode was
then causing the first display switch hotkey press to do nothing
(it would attempt to select "Join Displays" mode, but that was already
active).

Fixes: https://gitlab.gnome.org/GNOME/mutter/issues/281
https://gitlab.gnome.org/GNOME/mutter/merge_requests/213
2018-10-08 15:53:45 +08:00
Bastien Nocera
951219650f backend: Move lid-is-closed handling to MetaBackend
Rather than handle UpClient in both MetaBackend (to reset the idletime
when the lid is opened), and in MetaMonitorManager and
MetaMonitorConfigManager (to turn the screen under the lid on/off
depending on its status), move the ability to get the lid status from
UPower or mock it in one place, in MetaBackend.
2018-07-18 10:17:36 +00:00
Hans de Goede
f12e6ad4f1 monitor-config-manager: Adjust accelerometer rotation for panel-orientation
The device orientation coming out of iio-sensor-proxy defines upright/normal
as the direction in which the picture is displayed on the LCD panel without
any rotation. This is necessary for accelerometer rotation to work properly
in desktop environments which are not aware of panel-orientation issues.

This means that we need to correct the logical-monitor-config / user-visible
rotation for the panel-orientation when we get rotation info from
iio-sensor-proxy.

https://bugzilla.gnome.org/show_bug.cgi?id=782294
2017-12-25 17:01:45 +08:00
Hans de Goede
7917b083cb monitor-manager: Take drm-connector panel-orientation property into account
Some x86 clamshell design devices use portrait tablet LCD panels while
they should use a landscape panel, resoluting in a 90 degree rotated
picture.

Newer kernels detect this and rotate the fb console in software to
compensate. These kernels also export their knowledge of the LCD panel
orientation vs the casing in a "panel orientation" drm_connector property.

This commit adds support to mutter for reading the "panel orientation"
and transparently (from a mutter consumer's pov) fixing this by applying
a (hidden) rotation transform to compensate for the panel orientation.

Related: https://bugs.freedesktop.org/show_bug.cgi?id=94894

https://bugzilla.gnome.org/show_bug.cgi?id=782294
2017-12-25 17:01:45 +08:00
Jonas Ådahl
b7518c8651 monitor-manager: Compare keys when checking whether a config is complete
We only counted configured monitors and whether the config was
applicable (could be assigned), howeverwe didn't include disabled
monitors when comparing. This could caused incorrect configurations to
be applied when trying to use the previous configuration.

One scenario where this happened was one a system with one laptop
screen and one external monitor that was hot plugged some point after
start up. When the laptop lid was closed, the 'previous configuration'
being the configuration where only the laptop panel was enabled, passed
'is-complete' check as the number of configured monitors were correct,
and the configuration was applicable.

Avoid this issue by simply comparing the configuration key of the
previous configuration and the configuration key of the current state.
This correctly identifies a laptop panel with the lid closed as
inaccessible, thus doesn't incorrectly revert to the previous
configuration.

https://bugzilla.gnome.org/show_bug.cgi?id=788915
2017-11-30 11:48:44 +08:00
Jonas Ådahl
62dedfbef3 monitor-config-manager: Don't include closed laptop panel in config key
When deriving the list of disabled monitors when creating new monitors
configs, don't include the laptop panel if the lid is currently closed,
as we consider the laptop panel nonexistent when the laptop lid is
closed when it comes to configuration.

The laptop panel connector(s) will either way be appropriately disabled
anyway, as the field listing disabled monitors in the configuration do
not affect actual CRTC/connector assignments.

https://bugzilla.gnome.org/show_bug.cgi?id=788915
2017-11-30 11:48:44 +08:00
Jonas Ådahl
9817a6aa47 Make MetaOutput a GObject
Turn MetaOutput into a GObject and move it to a separate file. This
changes the storage format, resulting in changing the API for accessing
MetaOutputs from using an array, to using a GList.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
ea4dbd14bc monitor-config: Keep track of disabled monitors for stored configs
When saving and restoring monitor configurations, we must take disabled
monitors into account, as otherwise one cannot store/restore a
configuration where one or more monitors are explicitly disabled. Make
this possible by adding a <disabled> element to the <configure> element
which lists the monitors that are explicitly disabled. These ones are
included when generating the configuration key, meaning they'll be
picked up correctly.

https://bugzilla.gnome.org/show_bug.cgi?id=787629
2017-10-02 15:34:24 -04:00
Hans de Goede
1035200f26 monitor-config-manager: Fix 90/270 degree rotation not working
When rotating 90/270 degrees we need to swap width and height. This fixes
the screen going black and the following errors showing in the journal:

gnome-shell[1097]: Failed to set CRTC mode 800x1280: No space left on device
gnome-shell[1097]: Failed to flip: Device or resource busy
gnome-shell[1097]: Failed to set CRTC mode 800x1280: No space left on device
gnome-shell[1097]: Failed to set CRTC mode 800x1280: No space left on device

When rotating a tablet with accelerometer 90/270 degrees.

https://bugzilla.gnome.org/show_bug.cgi?id=787836
2017-09-22 20:09:04 +02:00
Jonas Ådahl
70e0fd0b45 backends: Chain up some GObjectClass vfuncs
Various vfunc implementations was not chained up properly. This commit
fixes that.

https://bugzilla.gnome.org/show_bug.cgi?id=787477
2017-09-20 11:14:27 +08:00
Jonas Ådahl
b140e7fbeb monitor-config-manager: Keep short history of configurations
In order to go back in monitor configurations, save them to a history.
The history is implemented as a max 3 element long queue, where newly
set configurations are pushed to the head, and old are popped from the
tail.

The difference between using a single previous config reference and a
queue is that we can now remember the configuration used prior to a
D-Bus triggered configuration when the user discarded the configuration.

This will later be used to restore a previous configuration when a
laptop lid is opened.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
bc3162460f Migrate old monitor configuration files to new system
This commit changes the new configuration system to use monitors.xml
instead of monitors-experimental.xml. When starting up and the
monitors.xml file is loaded, if a legacy monitors.xml file is
discovered (it has the version number 1), an attempt is made to migrate
the stored configuration onto the new system.

This is done in two steps:

1) Parsing and translation of the old configuration. This works by
parsing file using the mostly the old parser, but then translating the
resulting configuration structs into the new configuration system. As
the legacy configuration system doesn't carry over some state (such as
tiling and scale used), some things are not available. For tiling, the
migration paths makes an attempt to discover tiled monitors by
comparing EDID data, and guessing what the main tile is. Determination
of the scale of a migrated configuration is postponed until the
configuration is actually applied. This works by flagging the
configuration as 'migrated'.

2) Finishing the migration when applying. When a configuration with the
'migrated' flag is retrieved from the configuration store, the final
step of the migration is taken place. This involves calculating the
preferred scale given the mode configured, while making sure this
doesn't result in any overlapping logical monitor regions etc.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
e8a62861c9 Remove old monitor configuration system
Remove the old MetaMonitorConfig system and mark the new one as
non-experimental. This also removes the D-Bus property.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:20:53 +08:00
Rui Matos
3f9c5823cb backends: Add API to switch to predetermined monitor configurations
This will allows us to support the XF86Display key present on some
laptops, directly in mutter. This is also known, in evdev, as
KEY_SWITCHVIDEOMODE.

The common usage for this key is to alternate between a few well known
multi-monitor configurations though these aren't officially
standardized. As an example, Lenovo documents it as:

"Switches the display output location between the computer display
and an external monitor."

On this patch, we're just introducing the configurations that have been
implemented in g-s-d until now, which go a bit beyond the above
description.

https://bugzilla.gnome.org/show_bug.cgi?id=781906
2017-07-19 11:18:53 +02:00
Rui Matos
6d082bf442 monitor-config-manager: Add API to rotate the current config
This will allow us to do automatic rotation of the builtin display if
that's the only active monitor.

https://bugzilla.gnome.org/show_bug.cgi?id=781906
2017-07-14 15:31:20 +02:00
Jonas Ådahl
41eea5a942 monitor-config: Handle fractional scale precision loss
When calculating sizes given some size and a fractional logical monitor
scale with precision loss, round the result of the floating point
calculation to the closest integer, as otherwise we might end up with
result smaller by 1 if there was a loss of precision when calculating
the scale.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
b2a530b326 DisplayConfig: Make supported scales per mode
This changes the API to pass supported scales per mode instead of
providing a global list. This allows for more flexible scaling
scenarious, where a scale compatible with one mode can still be made
available even though another mode is incompatible.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
10b0351a59 Add support for rudimentary fractional scaling
When the logical layout mode is used, allow configuring the scaling to
be non-integer. Supported scales are so far hard coded to include at
most 1, 1.5 and 2, and scales that doesn't result in non-fractional
logical monitor sizes are discarded.

Wayland outputs are set to have scale ceil(actual_scale) meaning well
behaving Wayland clients will provide buffers with buffer scale 2, thus
being scaled down to the fractional scale.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
b64c69e4bc logical-monitor: Make scale a float
To support fractional scaling, the logical monitor scale must be stored
as a float. No other functional changes is part of this commit.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
1bb0e18042 monitor-manager/xrandr: Allow configuring scales on X11 too
This commit makes it possible to configure logical monitor scale also
when running on top of an X11 server using Xrandr. An extra property
'requires-globla-scale' is added to the D-Bus API is added to instruct
a configuration application to only allow setting a global logical
monitor scale.

This is needed to let gsd-xsettings use the configured state to set a
XSettings state that respects the explicit monitor configuration.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-05-26 14:31:48 +08:00
Jonas Ådahl
3f107da479 monitor-config-manager: Handle comparing different sized config keys
The guard for handling size differences between keys were broken, it
only checked if the key passed by the second argument ended up being
shorter.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-17 13:26:40 +08:00
Jonas Ådahl
95d0117784 monitor-manager: Hook up config manager to display config confirmation
Make it possible to confirm or cancel the new configuration also when
the new API is used.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
d804ecbd95 monitor-config-manager: Only make output primary if logical monitor
Only the first output of the first monitor of the primary logical
monitor should be made primary. This fixes an issue where the wrong
logical monitor ended up as primary when the logical state was derived.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
472a434212 monitor-config-manager: Support logical monitor transforms
Add support for rotated monitors. This is done per logical monitor, as
every monitor assigned to a logical monitor must be transformed in the
same way. This includes being transformed on the same level; e.g. if
the backend does not support transforming any monitor of a logical
monitor natively, then all monitors will be transformed using the
offscreen intermediate framebuffer.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:49 +08:00
Jonas Ådahl
afcc1bf512 monitor: Don't keep CRTC position in MetaMonitorCrtcMode
The CRTC position depends on the transform and how the transform is
implemented. The function calculating the positions still doesn't
support anything but the non-transformed case; this commit is in
preparation of adding support for transforms.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:49 +08:00
Jonas Ådahl
8163ca6821 Add support for scaled logical monitor framebuffers
This commit adds support for rendering onto enlarged per logical
monitor framebuffers, using the scaled clutter stage views, for HiDPI
enabled logical monitors.

This works by scaling the mode of the monitors in a logical monitors by
the scale, no longer relying on scaling the window actors and window
geometry for making windows have the correct size on HiDPI monitors.

It is disabled by default, as in automatically created configurations
will still use the old mode. This is partly because Xwayland clients
will not yet work good enough to make it feasible.

To enable, add the 'scale-monitor-framebuffer' keyword to the
org.gnome.mutter.experimental-features gsettings array.

It is still possible to specify the mode via the new D-Bus API, which
has been adapted.

The adaptations to the D-Bus API means the caller need to be aware of
how to position logical monitors on the stage grid. This depends on the
'layout-mode' property that is used (see the DisplayConfig D-Bus
documentation).

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
7eaeba520a monitor-config-manager: Verify monitor modes in logical monitor config
Verify that each monitor in a logical monitor has the same dimensions,
i.e. that it they all fill out the same logical monitor space.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
0548c9e7d5 MetaMonitorConfig: Rename is_underscanning to enable_underscanning
Use better terminology to imply that the configuration enables
underscanning, not what already "is".

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
68a6cc5976 monitor-config-manager: Verify the layout origin is at (0, 0)
The extent of the layout regions must be a rectangle positioned at
(0, 0).

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
2035f2f2e2 monitor-config-manager: Verify that logical monitors are adjecent
Logical monitors in a configuration must be adjecent to each other,
meaning there will be at least one pixel long side touching some other
logical monitor.

The exception to this is when there is only one logical monitor, which
cannot be adjecent to any other.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
b464004bb3 monitor-config-store: Move config verification to config manager
This way we can re-use it for example when verifying configurations
from D-Bus.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
a393a614a1 monitor-manager: Remove 'scale' from MetaOutput
Replace the 'scale' of an output with a vfunc on the MetaMonitorManager
class that takes a monitor and a monitor mode which calculates the
scale. On X11 this always returns 1, on KMS, the old formula is used.
On the dummy and test backends, the already configured values are
returned.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:46 +08:00
Jonas Ådahl
753e9c65a1 meta-monitor-config: Pass logical monitor scale via config
The default (calculated) scale is derived from the output, but
ultimately set via the monitor scale. This will enable config files to
override the scale. Yet to be done is handling when a scale is not
supported by a backend (i.e. the X11 backend).

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:46 +08:00
Jonas Ådahl
e8197e8e05 monitor-config-manager: Add underscanning to MetaMonitorConfig
Set the underscanning state via the monitor config struct so that it
can be configured.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
9b4e1903e1 monitor-config-manager: Prefer to use stored config
If not explicitly set by the backend, prefer to use the stored config
instead of creating a new one, if available.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
1ad386bc28 Introduce MetaMonitorConfigStore
MetaMonitorConfigStore provides an XML storage mechanism for
MetaMonitorConfigManager. It stores configuration files defined in the
same level as the MetaMonitorsConfig format, i.e. refers to high level
"monitors" and "monitor modes" instead of connectors and CRTCs.

Only reading custom files are implemented and so far unused.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
3f994646f2 monitor-config-manager: Handle headless setup gracefully
Handle headless setup gracefully by having no logical monitors. This
commit only makes the monitor management code deal with it; other areas
may still not be able to handle it.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
4b33f05eda monitor-config-manager: Add MetaMonitorsConfig creation helper
Add a meta_monitors_config_new() helper. It's exposed outside of
meta-monitor-config-manager.c already, as it'll be used externally in a
later commit.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
f19cb6a610 monitor-config-manager: Handle laptop lid being closed
Handle configuring when the laptop lid is closed. This is so far
handled by creating a linear configuration while ignoring the laptop
panel. Changing the current configuration will come later.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
a0af7e94a6 monitor-config-manager: Add support for suggested configuration
Create a suggested configuration, if such configuration is provided.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
644ee666f6 Introduce new monitor configuration system
The new monitor configuration system (MetaMonitorConfigManager) aims to
replace the current MetaMonitorConfig. The main difference between the
two is that MetaMonitorConfigManager works with higher level input
(MetaMonitor, MetaMonitorMode) instead of directly looking at the CRTC
and connector state. It still produces CRTC and connector configuration
later applied by the respective backends.

Other difference the new system aims to introduce is that the
configuration system doesn't manipulate the monitor manager state; that
responsibility is left for the monitor manager to handle (it only
manages configuration and creates CRTC/connector assignments, it
doesn't apply anything).

The new configuration system allows backends to not rely on deriving the
current configuration from the CRTC/connector state, as this may no longer be
possible (i.e. when using KMS and multiple framebuffers).

The MetaMonitorConfigManager system is so far disabled by default, as
it does not yet have all the features of the old system, but eventually
it will replace MetaMonitorConfig which will at that point be removed.
This will make it possible to remove old hacks introduced due to
limitations in the old system.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00