Since we want these accessed from bindings this must be a boxed
type. This has the side effect of making ClutterGrab a refcounted
object, since we want to avoid JS from pointing to freed memory
and maybe causing crashes if misusing the object after dismiss.
Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/2099>
This is (luckily!) unused, and it's inconvenient to have a toggle to
break the input model we are striving towards. Drop this function
and stick to the default behavior.
Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/2099>
Adding a <dbus/> element containing a boolean (yes/no) determines
whether org.gnome.Mutter.DisplayConfig ApplyMonitorsConfig will be
callable. The state is also introspectable via the
ApplyMonitorsConfigAllowed property on the same interface.
For example
<monitors version="2">
<policy>
<dbus>no</dbus>
</policy>
</monitors>
Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/2030>
The test aims to verify that setting the following policy
<policy>
<stores>
<store>system</store>
</stores>
</policy>
only applies monitor configurations from the system level.
Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/2030>
This adds a way to define a way, at the system level, to define a policy
of how monitor configuration files are loaded.
The intended use case is to e.g. either prefer system level monitor
configurations before user levels, or only allow system level
configurations.
Examples:
Prefer system over user level configurations:
<monitors version="2">
<policy>
<stores>
<store>system</store>
<store>user</store>
</stores>
</policy>
<configuration>
...
</configuration>
</monitors>
Only allow system level configurations:
<monitors version="2">
<policy>
<stores>
<store>system</store>
</stores>
</policy>
<configuration>
...
</configuration>
</monitors>
Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/2030>
The way device backends implement power saving differ, and power saving
needs to contain nothing incompatible in the same update. Make it
impossible to e.g. mode set, page flip, etc while entering power save by
not using MetaKmsUpdate's at all for this.
Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/2159>
When we're predicting state, i.e. when having posted an update while
avoiding reading KMS state, copy the predicted state, update the actual
state, and check that the predicted state matches the newly updated one.
Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/2159>
As other KMS tests, depends on being DRM master and vkms being loaded.
Currently consists of a sanity check that checks for the expected set of
connectors, CRTCs, planes, etc.
Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/2159>
It tests that if we go from (x is the pointer cursor)
+--------+
| |
| X |
+--------+
to
+----------------+
| |
| |
+--------+ |
| | |
| X | |
+--------+----------------+
i.e. making sure that X ends up somewhere within the logical monitor
region.
Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/2237>
These will be skipped by default, but can be run from a TTY for easier
debugging by doing:
dbus-run-session -- meson test -C build --suite mutter/native/tty --setup plain
Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/2151>
This commit makes it possible to run test executables in a test
environment constructed of a virtual machine running the Linux kernel
with the virtual KMS driver enabled, and a mocked system environment
using meta-dbus-runner.py/python-dbusmock.
The qemu machine is configured to use 256M of memory, as the default
128M was not enough for the tests to pass.
Using qemu is also only made possible on x86_64; more changes are needed
for it to be runnable on aarch64, so add a warning if it was enabled on
any other architecture.
Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/2151>
This is needed if one wants to run the test suite parts that need KMS or
evdev access in a virtual machine.
However, only initiate these methods if the meta-dbus-runner.py program
was launched with --kvm, as it's only suitable for using while running
as root in a virtual machine.
Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/2151>
There will be another mode added later, 'test'; prepare for this by
changing the existing "mode" boolean ('headless') to a mode, which is
either 'default' or 'headless'. Checking the is_headless variable is
changed to using the function is_headless(), except for one place, being
VT switching, which in preparation is only allowed on the 'default'
mode. Other places where it makes sense, the conditions are changed to
switch statements.
Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/2151>
The final tick of a timeline is >= its duration, but when using ticks that
are slightly in the future ("next presentation time") this means the final
tick will execute and complete the timeline up to one frame interval before
the timestamp of that final tick.
For the single clock test we now just check if the overall duration is
within one frame of the expected timeline duration.
The dual clock (switching) test needs a threshold of two frames because
starting each new clock creates a phase shift (error) of up to one frame.
Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/2161>
When checking panel orientation on logical monitors we should take
panel orientation transform to check it's properly applied, so ensure
that we're checking the right one.
Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/2090>