Tracking back from the monitor to the output every time we need to
figure out the scale of a window on a monitor is inconvenient, so
propagate the scale from the output to the monitor it is associated
with.
https://bugzilla.gnome.org/show_bug.cgi?id=744934
So that clients such as the control center can decide to hide an
underscanning checkbutton when the output does not support it.
Support in the KMS / native backend to come later...
The monitors info structure is created from the tiled outputs
and this is used as the central storage for info about a monitor
as opposed to the output state.
It appears at least the EDID mm w/h is for the whole monitor and
not per tile.
Some DRM drivers have added a consistent set of properties that
allow compensating for the overscan that some TVs do, without the
user being able to disable.
This function returns the monitor_info index corresponding to the given
coordinates, or -1 if none is found at that point. The native backend
has been changed in places where it could make use of this function.
https://bugzilla.gnome.org/show_bug.cgi?id=746896
This just exposes the type and the singleton getter necessary to make
it available to introspection. We'll expose more functionality as it
becomes needed.
https://bugzilla.gnome.org/show_bug.cgi?id=743745
EDID parsing has been refactored to a common meta_output_parse_edid()
function, which ensures the extracted information is the same on both KMS
and X11 backend, so it can be used consistently on eg. settings values.
https://bugzilla.gnome.org/show_bug.cgi?id=742882
It turns out that this was wrong because MetaWindow->monitor points to
the old monitor infos and they are needed to position windows in the
new configuration which happens in a monitors-changed handler.
This reverts commit e1704acda4.
We overrode the property for PowerSaveMode, which meant that gdbus's
auto-generated PropertiesChanged code wasn't being run.
This really confused gnome-rr and gnome-settings-daemon's power plugin
about the current DPMS state of the display, since they used their
cached PowerSaveMode properties, and never saw a PropertiesChanged being
emitted.
If a display was on, they set it to off, and then set it back on, the
setting back on would never fire, since they thought the display was
already off.
To fix this, remove our custom property override and just respond to
notifications on the object.
Namely, this fixes the DPMS management when receiving notifications so
that it now properly times out.
The output_id is more of an opaque identifier for the monitor, based on
its underlying ID from the windowing system. Since we also use the term
"output_id" for the output's index, rename our use of the opaque cookie
"output_id" to "winsys_id".
A gulong is not enough to get 64 bits in all arches, so we must
cast it, or we can corrupt the stack.
This was downstream bug bugzilla.redhat.com/show_bug.cgi?id=1002055
https://bugzilla.gnome.org/show_bug.cgi?id=707267
Right now this just has all of the files in one directory. We'll
be introducing more structure to this in the future, and build
a proper backend system.