We cleaned up an unused monitor config list, but what we should do is
clear up the logical monitor config list. This commit does that, as
well as removes the unused monitor config list.
We have not enough control over the sources of the refresh rate
float variable to make == comparisons reliable, add some room
when comparing these.
https://bugzilla.gnome.org/show_bug.cgi?id=787668
The reverted commit seems to cause
https://bugzilla.gnome.org/show_bug.cgi?id=787240 for some reason. Lets
be safe and revert it for now, as the code freeze is just around the
corner.
This partly (it doesn't reintroduce a whitespace issue) reverts commit
dbc63430d8.
The foreach CRTC monitor mode helper incorrectly iterated over outputs
without CRTC when non-tiled modes were set on tiled monitors. This was
not expected by callers, so fix the helper to only iterate over active
outputs (that has or should have a CRTC).
The test cases uses the incorrect behaviour of the foreach CRTC helper
to check that the disabled outputs mode are set to NULL, so add a
foreach output helper and change the tests to use that instead.
https://bugzilla.gnome.org/show_bug.cgi?id=730551
When headless, we don't have any logical monitors to derive a screen
size from, but we can't set it to empty as that will cause issues with
the clutter stage, UI widget layout and other things. To avoid such
issues, just fall back to a 640 x 480 screen size when headless.
https://bugzilla.gnome.org/show_bug.cgi?id=730551
Due to rounding issues, we can't assume a floating point calculation
will end up on an integer, even if we got the factor from the reverse
calculation. Thus, to avoid casting away values like N.999... to N,
when they should really be N+1, round the resulting floating point
calculation before casting it to int.
This fixes an issue where using the scale ~1.739 on a 1920x1080 mode
resulted in error when setting the mode, as the calculated size of the
framebuffer was only 1919x1080.
https://bugzilla.gnome.org/show_bug.cgi?id=786918
When a screen cast session is stand-alone, i.e. not created given a
remote desktop session managing it, allow calling the Start/Stop
methods to start and stop it.
https://bugzilla.gnome.org/show_bug.cgi?id=784199
As of commit 5f5ef3de2cdc816dab82cb7eb5d7171bee0ad2c5 in pipewire the
stream creator can find out the node ID of the stream it created.
So instead of using a special purpose entry to the info property box to
let the application discover stream by monitoring added nodes searching
for the given special purpose entry, just pass the node directly.
https://bugzilla.gnome.org/show_bug.cgi?id=784199
When the PipeWire context or stream ends up in an error state, signal
that the source has closed. This then triggers the stream and finally
the session to be closed too.
https://bugzilla.gnome.org/show_bug.cgi?id=784199
This commit adds basic screen casting and remote desktoping
functionalty. This works by exposing two D-Bus API services:
org.gnome.Mutter.ScreenCast and org.gnome.Mutter.RemoteDesktop.
The remote desktop API is used to create remote desktop sessions. For
each session, a D-Bus object is created, and an application can manage
the session by sending messages to the session object. A remote desktop
session the user to emit input events using the D-Bus methods on the
session object. To get framebuffer content, the application should
create an associated screen cast session.
The screen cast API is used to create screen cast sessions. One can so
far either create stand-alone screen cast sessions, or a screen cast
session associated with a remote desktop session. A remote desktop
associated screen cast session is managed by the remote desktop session.
So far only remote desktop managed screen cast sessions are implemented.
Each screen cast session may have one or more streams. A screen cast
stream is a stream of buffers of some part of the compositor content.
So far API exists for creating streams of monitors and windows, but
only monitor streams are implemented.
When a screen cast session is started, the one PipeWire stream is
created for each screen cast stream created for the session. When this
has happened, a PipeWireStreamAdded signal is emitted on the stream
object, passing a unique identifier. The application may use this
identifier to find the associated stream being advertised by the
PipeWire daemon.
The remote desktop and screen cast functionality must be explicitly be
enabled at ./configure time by passing --enable-remote-desktop to
./configure. Doing this will build both screen cast and remote desktop
support.
To actually enable the screen casting and remote desktop, the user must
enable the experimental feature. See
org.gnome.mutter.experimental-features.
https://bugzilla.gnome.org/show_bug.cgi?id=784199
When monitors changed, previous monitor instances are defunct, and any
reference holder should drop its reference. Sometimes they will want to
continue having a reference to the same monitor, so add this function
to make it possible to find it.
Currently the output and crtc references are invalid, as they are not
yet reference counted, so this can only look at cached fields.
https://bugzilla.gnome.org/show_bug.cgi?id=784199
Trying to unilaterally require eglGetPlatformDisplayEXT causes problems in
scenarios where this method is not available. Besides, this should only be
required on Wayland, so we can stop requiring it always and simply let the
eglGetPlatformDisplay() function error accordingly when needed.
https://bugzilla.gnome.org/show_bug.cgi?id=786619
The HW cursor plane can't do any transformations, and as we still don't
pre-transform any buffer before uploading to the cursor plane, we must
disable the HW cursor when a logical monitor is transformed.
This worked previously because the transform of a MetaCrtc did not
correspond to the transform of a CRTC, but the transform of the logical
monitor the CRTC was assigned to.
https://bugzilla.gnome.org/show_bug.cgi?id=786023
When another D-Bus call that just tries to verify a configuration is
made, don't cancel any active monitor configuration dialog, as doing so
would effectively confirm queried configuration.
https://bugzilla.gnome.org/show_bug.cgi?id=786023
Add API to get the layout group (layout index) currently active. In the
native backend this is done by fetching the state directly from the
evdev backend; on X11 this works by listening for XkbStateNotify
events, caching the layout group value.
https://bugzilla.gnome.org/show_bug.cgi?id=786408
Don't wait for clutter to initialize for connecting to X11; do it when
constructing the backend instance. This way we can later depend on
having an X11 connection earlier during initialization.
https://bugzilla.gnome.org/show_bug.cgi?id=786408
When opening a laptop lid, one will likely want to restore the
configuration one had prior to closing it, so when ensuring monitor
configuration, first try to see if the previously set configuration is
both complete (all connected monitors are configured) and applicable
(it is a valid configuration) and only try to generate a new from
scratch if that failed.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
In order to go back in monitor configurations, save them to a history.
The history is implemented as a max 3 element long queue, where newly
set configurations are pushed to the head, and old are popped from the
tail.
The difference between using a single previous config reference and a
queue is that we can now remember the configuration used prior to a
D-Bus triggered configuration when the user discarded the configuration.
This will later be used to restore a previous configuration when a
laptop lid is opened.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
This commit changes the new configuration system to use monitors.xml
instead of monitors-experimental.xml. When starting up and the
monitors.xml file is loaded, if a legacy monitors.xml file is
discovered (it has the version number 1), an attempt is made to migrate
the stored configuration onto the new system.
This is done in two steps:
1) Parsing and translation of the old configuration. This works by
parsing file using the mostly the old parser, but then translating the
resulting configuration structs into the new configuration system. As
the legacy configuration system doesn't carry over some state (such as
tiling and scale used), some things are not available. For tiling, the
migration paths makes an attempt to discover tiled monitors by
comparing EDID data, and guessing what the main tile is. Determination
of the scale of a migrated configuration is postponed until the
configuration is actually applied. This works by flagging the
configuration as 'migrated'.
2) Finishing the migration when applying. When a configuration with the
'migrated' flag is retrieved from the configuration store, the final
step of the migration is taken place. This involves calculating the
preferred scale given the mode configured, while making sure this
doesn't result in any overlapping logical monitor regions etc.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
The zero-initialized winsys id was incorrectly used as the key to find
the old output to base active/primary state from, which would never
succeed unless the winsys id happened to be 0. Fix this by using the
winsys id that will be used, i.e. the connector id.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
The 'normal' transform has the value 0, so the g_warn_if_fail()
expression failed. Correct it so that it doesn't complain when no
transform is checked.
https://bugzilla.gnome.org/show_bug.cgi?id=777732
The problem is that libinput offers the possibility to not enabled
dragging when tap-to-click is enabled but mutter doesn't. For people who
have a sensitive touchpad and who like tap-to-click option, dragging is
launched even when you don't want it : for example, when you select a
folder, most of the time the folder is dragging whereas just selected or
when you want to select some lines of a text file, several lines are
moved as a cut-paste which is not expected and erase datas.
To fix it, you need to have the possibility to desactivate the drag
option when you use tap-to-click in mutter. Because it's already a
specification of libinput, it remains to add it to mutter.
Implementation with X11 is added too.
https://bugzilla.gnome.org/show_bug.cgi?id=775755
When suspending (i.e. VT switching away, the GDM gnome-shell instance
gets hidden, or changing user), destroy the onscreen and offscreen
monitor framebuffers. When resuming, the stage views and framebuffers
will be recreated anyway.
https://bugzilla.gnome.org/show_bug.cgi?id=786299
This will allows us to support the XF86Display key present on some
laptops, directly in mutter. This is also known, in evdev, as
KEY_SWITCHVIDEOMODE.
The common usage for this key is to alternate between a few well known
multi-monitor configurations though these aren't officially
standardized. As an example, Lenovo documents it as:
"Switches the display output location between the computer display
and an external monitor."
On this patch, we're just introducing the configurations that have been
implemented in g-s-d until now, which go a bit beyond the above
description.
https://bugzilla.gnome.org/show_bug.cgi?id=781906
Instead of letting MetaMonitor derive the logical monitor size, then
using the main monitor for the position, just let MetaMonitor derive
the whole layout including the position. This means it can deal with
tiled monitors better, for example when the main output (the output
always active when the monitor is active) is not the origin output (the
output with tile position (0, 0)).
https://bugzilla.gnome.org/show_bug.cgi?id=781723
Just like we do for buttons, with a few twists. These have 2 directions
mappable to different keycombos, and are affected by the current mode
in their group.
https://bugzilla.gnome.org/show_bug.cgi?id=782033
This basically moves g-s-d's orientation plugin into mutter so that
eventually g-s-d doesn't need to build monitor configurations by
itself anymore.
https://bugzilla.gnome.org/show_bug.cgi?id=781906