Commit Graph

102 Commits

Author SHA1 Message Date
Jonas Ådahl
7226c5c7bf backend/native: Remove leftover stage view checks
We haven't supported disabling stage views in the native backend since

commit 70edc7dda4
Author: Jonas Ådahl <jadahl@gmail.com>
Date:   Mon Jul 24 12:31:32 2017 +0800

    backends/native: Stop supporting stage views being disabled

There were still some left over checks; lets remove them.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/343
2018-12-04 15:04:50 +01:00
Emilio Pozuelo Monfort
ad7d6e4a37 backends/native: React to GPU hotplug
If a GPU is added at runtime, we should connect to it and manage
its outputs.
2018-11-21 14:33:00 +01:00
Emilio Pozuelo Monfort
a6178990cd monitor-manager/kms: Use non-pci secondary cards
We may have secondary non-PCI devices, and we should drive their
outputs.
2018-11-21 14:26:02 +01:00
Jonas Ådahl
2f4a68c8c3 Clean up include macros mess
The order and way include macros were structured was chaotic, with no
real common thread between files. Try to tidy up the mess with some
common scheme, to make things look less messy.
2018-11-06 17:17:36 +01:00
Iain Lane
deb541ef5a monitor-manager-kms: Check if GPUs can have outputs
We need a way for mutter to exit if no available GPUs are going to work.
For example if gdm starts gnome-shell and we're using a DRM driver that
doesn't work with KMS then we should exit so that GDM can try with Xorg,
rather than operating in headless mode.

Related: https://gitlab.gnome.org/GNOME/mutter/issues/223
2018-08-21 13:16:22 +00:00
Armin Krezović
390314adfb Rename errors.[ch] to meta-x11-errors.[ch]
Also rename meta_error_trap_* to meta_x11_error_trap_* and
move meta-x11-errors.c to src/x11

https://bugzilla.gnome.org/show_bug.cgi?id=759538
2018-07-06 19:47:17 +02:00
Jonas Ådahl
1200182d70 backends: Move MetaOutput::crtc field into private struct
No functional changes. This is only done so that changes to reference
counting can done more reliably.

https://bugzilla.gnome.org/show_bug.cgi?id=786929
2018-06-28 13:42:15 +02:00
Georges Basile Stavracas Neto
773b8384fa monitor-manager-kms: Don't add GPU if it fails
This is a small mistake spotted while working on a solution
for #77. When a GPU fails to initialize, we're adding them
anyway, which might have pretty bad consequences when trying
to use these NULL GPUs.

Issue: #77
2018-04-16 16:30:21 +02:00
Georges Basile Stavracas Neto
7fdac6d310 monitor-manager-kms: Use g_autoptr for error
A minor code cleanup.
2018-04-16 16:30:21 +02:00
Jonas Ådahl
cbcf6a4f23 monitor-manager-kms: Add all GPUs with connectors
First find the primary GPU and open it. Then go through all other
discovered GPUs with connectors and add those too. MetaRendererNative
still fails to initialize when multiple added GPUs and
MetaCursorRendererNative still always falls back on OpenGL based cursor
rendering when there are multiple GPUs.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 18:17:26 -04:00
Jonas Ådahl
c1683073f1 backends: Split out CRTC/output management to MetaGpu
In order to eventually support multilpe GPUs with their own connectors,
split out related meta data management (i.e. outputs, CRTCs and CRTC
modes) into a new MetaGpu GObject.

The Xrandr backend always assumes there is always only a single "GPU" as
the GPU is abstracted by the X server; only the native backend (aside
from the test backend) will eventually see more than one GPU.

The Xrandr backend still moves some management to MetaGpuXrandr, in
order to behave more similarly to the KMS counterparts.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 18:05:20 -04:00
Jonas Ådahl
315a6f43d7 monitor-manager: Keep pointer to backend
Instead of accessing the global singleton, keep a pointer to the
backend in the MetaMonitorManager struct.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
16a6aef5a7 backends/native: Move KMS fd management to monitor manager
Move finding, opening and managment of the KMS file descriptor to
MetaMonitorManagerKms. This means that the monitor manager creation can
now fail, both if more than one GPU with connectors is discovered, or
if finding or opening the primary GPU fails.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
518fb9fb5e backends: Split monitor manager creation into create and setup
The monitor manager instance was created and setup in one step; at
construction. This is problematic if, in the future, the monitor manager
creation can fail, as the monitor manager is created quite late.

To make it possible to in the future fail creating a monitor manager,
create the instance very early when initiating the backend, then on
post init backend setup, "setup" the monitor manager state, i.e. read
the current state and setup the stage.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
de40ced8b4 backends/native: Move CRTC code to its own file
Move code dealing with MetaCrtcKms and related functionality to its
own file. Eventually, MetaCrtcKms should become a GObject based on
MetaCrtc, and this commit is in preparation for that.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
cfee58798e backends/crtc: Keep a pointer to the monitor manager
Instead of passing it around or fetching the singleton, keep a pointer
to the monitor manager that owns the CRTC. This will eventually be
replaced with a per GPU/graphics card object.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
7ea01693a7 backends/native: Move output code to its own file
Move code dealing with MetaOutputKms and related functionality to its
own file. Eventually, MetaOutputKms should become a GObject based on
MetaOutput, and this commit is in preparation for that.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
e0d839aea2 backends/output: Keep a pointer to the monitor manager
Instead of passing it around or fetching the singleton, keep a pointer
to the monitor manager that owns the output. This will eventually be
replaced with a per GPU/graphics card object.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
2db5505216 monitor-manager: Turn MetaCrtcMode into a GObject
Convert MetaCrtcMode from a plain struct to a GObject. This changes the
storage format, and also the API, as the API was dependent on the
storage format.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
f44b6c772a monitor-manager/kms: Some naming fixes
Prefix external types (e.g mode -> drm_mode) and rename a search
function to not refer to a local type as ".._meta_..".

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
f64fab1d2d monitor-manager: Make MetaCrtc a GObject
Turn MetaCrtc into a GObject and move it to a separate file. This
changes the storage format, resulting in changing the API for accessing
MetaCrtcs from using an array, to using a GList.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
9817a6aa47 Make MetaOutput a GObject
Turn MetaOutput into a GObject and move it to a separate file. This
changes the storage format, resulting in changing the API for accessing
MetaOutputs from using an array, to using a GList.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Hans de Goede
7e3a780dcd monitor-config-manager-kms: Fix is_transform_handled
meta_monitor_manager_kms_is_transform_handled should checked the
transform passed as function argument, not the current crtc transform.

https://bugzilla.gnome.org/show_bug.cgi?id=787836
2017-09-22 20:09:04 +02:00
Jonas Ådahl
0aa7405a2a monitor-manager: Fall back to minimum screen size of 640 x 480
When headless, we don't have any logical monitors to derive a screen
size from, but we can't set it to empty as that will cause issues with
the clutter stage, UI widget layout and other things. To avoid such
issues, just fall back to a 640 x 480 screen size when headless.

https://bugzilla.gnome.org/show_bug.cgi?id=730551
2017-08-30 13:09:38 +08:00
Jonas Ådahl
27a4f9f862 monitor-manager/kms: Use connector id to find old output
The zero-initialized winsys id was incorrectly used as the key to find
the old output to base active/primary state from, which would never
succeed unless the winsys id happened to be 0. Fix this by using the
winsys id that will be used, i.e. the connector id.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
e8a62861c9 Remove old monitor configuration system
Remove the old MetaMonitorConfig system and mark the new one as
non-experimental. This also removes the D-Bus property.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:20:53 +08:00
Jonas Ådahl
b2a530b326 DisplayConfig: Make supported scales per mode
This changes the API to pass supported scales per mode instead of
providing a global list. This allows for more flexible scaling
scenarious, where a scale compatible with one mode can still be made
available even though another mode is incompatible.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
10b0351a59 Add support for rudimentary fractional scaling
When the logical layout mode is used, allow configuring the scaling to
be non-integer. Supported scales are so far hard coded to include at
most 1, 1.5 and 2, and scales that doesn't result in non-fractional
logical monitor sizes are discarded.

Wayland outputs are set to have scale ceil(actual_scale) meaning well
behaving Wayland clients will provide buffers with buffer scale 2, thus
being scaled down to the fractional scale.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
b64c69e4bc logical-monitor: Make scale a float
To support fractional scaling, the logical monitor scale must be stored
as a float. No other functional changes is part of this commit.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
1bb0e18042 monitor-manager/xrandr: Allow configuring scales on X11 too
This commit makes it possible to configure logical monitor scale also
when running on top of an X11 server using Xrandr. An extra property
'requires-globla-scale' is added to the D-Bus API is added to instruct
a configuration application to only allow setting a global logical
monitor scale.

This is needed to let gsd-xsettings use the configured state to set a
XSettings state that respects the explicit monitor configuration.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-05-26 14:31:48 +08:00
Jonas Ådahl
3b097c7e77 monitor-manager/kms: Move scale calculation to MetaMonitor
The scale calculation doesn't really have anything to do with KMS, and
eventually we'll want to have mutter calculate the monitor scale for
non-KMS backends too, so move the scale calculation to MetaMonitor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-05-26 14:31:48 +08:00
Jonas Ådahl
0bc312a54b monitor-manager/kms: Move global ui scaling setting to MetaSettings
It'll be used elsewhere, so shouldn't be in MetaMonitorManagerKms.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-05-26 14:31:48 +08:00
Jonas Ådahl
2718699ccc backend: Move settings into a new MetaSettings object
Introduce MetaSettings and add the settings managed by MetaBackend into
the new object. These settings include: experimental-features and UI
scaling factor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-05-26 14:31:48 +08:00
Jonas Ådahl
0c64c35a8a monitor-manager: Make the config manager an 'experimental feature'
Instead of using a environment variable, add a new 'experimental
feature' gsetting keyword "monitor-config-manager" that enables the use
of the new MetaMonitorConfigManager. This commit also makes it possible
to switch between the two systems without restarting mutter.

The D-Bus API is disabled when the experimental feature is not enabled,
and clients trying to access it will get a access-denied error in
response. A new property 'IsExperimentalApiEnabled' is added to let the
D-Bus client know whether it is possible to use the experimental API or
not.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
8163ca6821 Add support for scaled logical monitor framebuffers
This commit adds support for rendering onto enlarged per logical
monitor framebuffers, using the scaled clutter stage views, for HiDPI
enabled logical monitors.

This works by scaling the mode of the monitors in a logical monitors by
the scale, no longer relying on scaling the window actors and window
geometry for making windows have the correct size on HiDPI monitors.

It is disabled by default, as in automatically created configurations
will still use the old mode. This is partly because Xwayland clients
will not yet work good enough to make it feasible.

To enable, add the 'scale-monitor-framebuffer' keyword to the
org.gnome.mutter.experimental-features gsettings array.

It is still possible to specify the mode via the new D-Bus API, which
has been adapted.

The adaptations to the D-Bus API means the caller need to be aware of
how to position logical monitors on the stage grid. This depends on the
'layout-mode' property that is used (see the DisplayConfig D-Bus
documentation).

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
f25f14351c monitor-manager: Make max screen size optional
Make the concept of maximum screen size optional, as it is not
necessarily a thing on all systems (e.g. when using the native backend
and stage views).

The meta_monitor_monitor_get_limits() function is replaced by a
meta_monitor_manager_get_max_screen_size() which fails when no screen
limit is available. Callers and other users of the previous max screen
size fields are updated to deal with the fact that the limit is
optional.

The new D-Bus API is changed to move it to the properties bag, where
its absence means there is no applicable limit.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
691e7951ea DisplayConfig: Add new API for configuring monitors
Add a new D-Bus API that uses the state from GetCurrentState to
configure high level monitors, instead of low level CRTCs and
connectors. So far persistent configuration is not implemented, as
writing to the configuration store is still not supported.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
d050fdb17f monitor-manager: Add per backend capabilities
Add a private API for querying backend capabilities. For now, only
mirroring capability is reported.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
9e8ee491e6 monitor-manager: Add API to get scales supported by the backend
For the Xrandr backend, only scale 1 is supported, for the others, 1
and 2 are reported as supported.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
fcc0288f0c monitor-manager: Let the backends handle no configuration
Let the backends decide whether to just rebuild a derived state, or use
the NULL config to rebuild an empty logical state.

This also changes the expected screen size values of the no-outputs
test; as this case is actually handled now.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
a393a614a1 monitor-manager: Remove 'scale' from MetaOutput
Replace the 'scale' of an output with a vfunc on the MetaMonitorManager
class that takes a monitor and a monitor mode which calculates the
scale. On X11 this always returns 1, on KMS, the old formula is used.
On the dummy and test backends, the already configured values are
returned.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:46 +08:00
Carlos Garnacho
70a4f59960 backends: Calculate output scale correctly on vertical transforms
The code calculating the output scale involves calculations around pixel
and mm sizes, however we do compare post-transformation pixel sizes to
untransformed mm sizes, which breaks the DPI calculations. Fix this by
transforming back pixel sizes back to untransformed.

While we're at it, actually compare the output height to HIDPI_MIN_HEIGHT
instead of its width, it seems right according to the #define name and
comment.

https://bugzilla.gnome.org/show_bug.cgi?id=777687
2017-03-24 18:11:01 +01:00
Jonas Ådahl
eb3ff3f44a monitor-manager-kms: Don't try to wait for EDID on hot plug
The mitigation to avoid missing EDID blob was incorrect; the reason it
sometimes failed to read was a race between different applications all
trying to read the EDID at the same time. E.g. gnome-shell as GDM would
at the same time as the session gnome-shell try to read the EDID of the
same connector at the same time, triggering a race in the kernel,
making the blob reading ioctl occationally fail with ENOENT.

Remove this mitigation, as it didn't really mitigate anything; the race
could just as well happen when doing the actual read later.

https://bugzilla.gnome.org/show_bug.cgi?id=779837
2017-03-11 09:16:33 +08:00
Jonas Ådahl
db14e6099e monitor-manager-kms: Don't listen on hotplugs when paused
When mutter is paused (i.e. not the DRM master), stop listening on
hotplug events. Instead read the current state and set modes when
resumed.

This avoids a race condition in the drm API which currently only
manages to properly deal with one application querying the EDID state
at the same time when there are multiple mutter instances running at
the same time (e.g. gnome-shell driving gdm at the same time as
gnome-shell as the session instance).

https://bugzilla.gnome.org/show_bug.cgi?id=779837
2017-03-11 09:16:33 +08:00
Jonas Ådahl
5aa02c0378 monitor-manager-kms: Improve EDID error reporting
Include the connector name in the error message, and only include the
reason in the GError message.

https://bugzilla.gnome.org/show_bug.cgi?id=779837
2017-03-11 09:16:33 +08:00
Jonas Ådahl
73b2b30a1d monitor-manager-kms: Put uevent signal management in helpers
https://bugzilla.gnome.org/show_bug.cgi?id=779837
2017-03-11 09:16:27 +08:00
Jonas Ådahl
944339f6a5 monitor-manager: Expose whether the backend handles a transform
Expose via a new API whether the transform on a logical monitor is
handled by the backend. This was previously only exposed only in the
native backend. This will be used to emulate not supporting transforms
in the backend in the nested backend.

https://bugzilla.gnome.org/show_bug.cgi?id=779745
2017-03-09 10:17:30 +08:00
Jonas Ådahl
3f994646f2 monitor-config-manager: Handle headless setup gracefully
Handle headless setup gracefully by having no logical monitors. This
commit only makes the monitor management code deal with it; other areas
may still not be able to handle it.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
644ee666f6 Introduce new monitor configuration system
The new monitor configuration system (MetaMonitorConfigManager) aims to
replace the current MetaMonitorConfig. The main difference between the
two is that MetaMonitorConfigManager works with higher level input
(MetaMonitor, MetaMonitorMode) instead of directly looking at the CRTC
and connector state. It still produces CRTC and connector configuration
later applied by the respective backends.

Other difference the new system aims to introduce is that the
configuration system doesn't manipulate the monitor manager state; that
responsibility is left for the monitor manager to handle (it only
manages configuration and creates CRTC/connector assignments, it
doesn't apply anything).

The new configuration system allows backends to not rely on deriving the
current configuration from the CRTC/connector state, as this may no longer be
possible (i.e. when using KMS and multiple framebuffers).

The MetaMonitorConfigManager system is so far disabled by default, as
it does not yet have all the features of the old system, but eventually
it will replace MetaMonitorConfig which will at that point be removed.
This will make it possible to remove old hacks introduced due to
limitations in the old system.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
ee0677a021 monitor-manager: Let backend implementations handle inital config
How the initial configuration is done depends on the backend, so let
them do it themself.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00