Commit Graph

111 Commits

Author SHA1 Message Date
Jonas Ådahl
fadffe3fad wayland/xdg-shell: Add toplevel bounds support
This implements the new 'bounds' event that is part of the xdg_toplevel
interface in the xdg-shell protocol. It aims to let clients create
"good" default window sizes that depends on e.g. the resolution of the
monitor the window will be mapped on, whether there are panels taking up
space, and things like that.

Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/2167>
2022-03-04 14:48:25 +00:00
Bilal Elmoussaoui
7717383deb meson: Allow to build without gnome-desktop
gnome-desktop is used to retrieve the monitor vendor name which in some
use cases is not needed  as it brings a bunch of gnome-desktop unwanted
dependencies.
The change makes mutter fallback to an "Undefined" vendor name if it is
built without gnome-desktop

Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/2317>
2022-03-03 15:07:38 +00:00
Marco Trevisan (Treviño)
8cf3485ab0 monitor-manager: Notify privacy screen changes on hotkey press
When privacy screen is changed and this happens on explicit user request
(that is not a setting change) we should notify about this via an OSD.

To perform this, we keep track of the reason that lead to a privacy
screen change, and when we record it we try to notify the user about.

When the hardware has not an explicit hotkey signal but we record a
change we must still fallback to this case.

Fixes: #2105
Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1952>
2022-01-25 07:31:19 +00:00
Marco Trevisan (Treviño)
f96a167aea monitor-manager: Apply privacy monitor settings on changes
When both a setting change and a monitor change happens we need to
ensure that the monitor settings are applied.
This is currently only related to privacy settings, but will in future
also handle other monitor parameters such as brightness.

Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1952>
2022-01-25 07:31:19 +00:00
Marco Trevisan (Treviño)
ef0f708404 monitor-manager: Use connect_object to connect to settings signals
We were disconnecting from the wrong object, so instead of adjusting it
we can simply use "new" utility functions instead.

Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1964>
2021-09-20 15:37:59 +00:00
Marco Trevisan (Treviño)
d5f397977e monitor-unit-tests: Add tests with dynamic orientation changes
Verify monitors disposition when we have rotation changes coming from
MetaOrientationManager, using our mock dbus implementation.

Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1233>
2021-09-04 10:04:01 +02:00
Marco Trevisan (Treviño)
67eb60c19a monitor-manager: Pass the Logical mode when computing the monitor scale
In order to compute proper default scaling value we need to know if the
fractional scaling is enabled or not and thus if we're using a logical
mode or not.

Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/336>
2021-07-22 13:14:01 +02:00
Jonas Ådahl
91117bb052 monitor-manager: Don't include generated code in header file
Meson doesn't seem to handle depending on generated headers, at least
when those headers are pulled in indirectly via another header file.

Luckily, we don't actually need to include the generated D-Bus boiler
plate in meta-monitor-manager-private.h, since the MetaMonitorManager
type no longer is based on the D-Bus service skeleton.

So, by moving the inclusion of the generated D-Bus header file into
meta-monitor-manager.c, we should hopefully get rid of the sporadic
build issues.

Closes: https://gitlab.gnome.org/GNOME/mutter/-/issues/1682
Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1819>
2021-04-14 16:22:24 +00:00
Jonas Ådahl
51ff51c854 tests: Add virtual monitor tests
The testing currently done is:

 * Creating a virtual monitor succeeds and gets the right configuration
 * Painting a few times results in the expected output
 * Changing the content of the stage also changes the painted content
   accordingly
 * Destroying the virtual monitor works as expected

Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1698>
2021-03-12 15:09:45 +00:00
Jonas Ådahl
d7ce6a47f8 tests: Add reference test framework
This adds a test framework that makes it possible to compare the result
of painting a view against a reference image. Test reference as PNG
images are stored in src/tests/ref-tests/.

Reference images needs to be created for testing to be able to succeed.
Adding a test reference image is done using the
`MUTTER_REF_TEST_UPDATE` environment variable. See meta-ref-test.c for
details.

The image comparison code is largely based on the reference image test
framework in weston; see meta-ref-test.c for details.

Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1698>
2021-03-12 15:09:45 +00:00
Jonas Ådahl
1818d21da5 Introduce virtual monitors
Virtual monitors are monitors that isn't backed by any monitor like
hardware. It would typically be backed by e.g. a remote desktop service,
or a network display.

It is currently only supported by the native backend, and whether the
X11 backend will ever see virtual monitors is an open question. This
rest of this commit message describes how it works under the native
backend.

Each virutal monitor consists of virtualized mode setting components:

 * A virtual CRTC mode (MetaCrtcModeVirtual)
 * A virtual CRTC (MetaCrtcVirtual)
 * A virtual connector (MetaOutputVirtual)

In difference to the corresponding mode setting objects that represents
KMS objects, the virtual ones isn't directly tied to a MetaGpu, other
than the CoglFramebuffer being part of the GPU context of the primary
GPU, which is the case for all monitors no matter what GPU they are
connected to. Part of the reason for this is that a MetaGpu in practice
represents a mode setting device, and its CRTCs and outputs, are all
backed by real mode setting objects, while a virtual monitor is only
backed by a framebuffer that is tied to the primary GPU. Maybe this will
be reevaluated in the future, but since a virtual monitor is not tied to
any GPU currently, so is the case for the virtual mode setting objects.

The native rendering backend, including the cursor renderer, is adapted
to handle the situation where a CRTC does not have a GPU associated with
it; this in practice means that it e.g. will not try to upload HW cursor
buffers when the cursor is only on a virtual monitor. The same applies
to the native renderer, which is made to avoid creating
MetaOnscreenNative for views that are backed by virtual CRTCs, as well
as to avoid trying to mode set on such views.

Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1698>
2021-03-12 15:09:45 +00:00
Jonas Ådahl
432682f305 monitor-manager: Clean up hot-plug paths slightly
Make the API used more shared and better named.

meta_monitor_manager_on_hotplug() was renamed
meta_monitor_manager_reconfigure(), and meta_monitor_manager_reload()
was introduced to combine reading the current state and reconfiguring.

Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1689>
2021-01-28 20:05:23 +00:00
Jonas Ådahl
e41a0e47dc monitor-manager: Cleanup class struct
It was wierdly formatted, missed argument variable names, didn't use
stdint types. Clean this up a bit.

Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1689>
2021-01-28 20:05:23 +00:00
Aaron Plattner
e88467f9d7 x11: Support the CTM (color transform matrix) RandR property
When supported, this property allows the window system to apply a 3x3 color
correction matrix in order to transform colors from the window system's native
color space to the measured color space of a display device.

Query for this property and set the 'supports-color-transform' property in the
GetResource reply. Add support for the SetOutputCTM DBus method and plumb that
through to the server's CTM property.

Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1048>
2021-01-11 13:44:54 +00:00
Carlos Garnacho
0c1d48bd08 backends: Add simple object to delegate logical monitor layout queries
This object can be passed to random places, and be trusted to remain unchanged
till replaced. Makes it an ideal replacement for MetaMonitorManager across
threads.

Part-of: <https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1403>
2020-11-27 15:14:33 +00:00
Uday Kiran Pichika
9d0bac0754 output: Move edid parse function to the right file
Move the edid parsing function from MetaMonitorManager to MetaOutput
to read the monitor manufacturer,serial,vendor,etc.

https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1516/
2020-10-21 17:04:44 +05:30
Carlos Garnacho
bbcd65ce38 backends: Hook ClutterSeat::touch-mode to PanelOrientationManaged
We only want the panel autorotation to happen if the laptop has an
accelerometer, and is in tablet mode. Regular laptop mode should
lock the orientation, and let it be configured manually.

https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1311
2020-09-05 07:25:02 +00:00
Carlos Garnacho
1acf744473 backends: Centralize panel autorotation in a DisplayConfig property
Instead of having everyone check net.hadess.SensorProxy themselves, have
this all controlled by the MetaOrientationManager, and proxied everywhere
else via a readonly property in org.gnome.Mutter.DisplayConfig.

We want to attach more complex policies here, and it seems better to
centralize the handling of the autorotation feature rather than
implementing policy changes all over the place.

https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1311
2020-09-05 07:25:02 +00:00
Jonas Ådahl
b69111d8e6 monitor-manager: Rename *Info structs to *Assignment
MetaCrtcInfo and MetaOutputInfo did not represent information about
MetaCrtc and MetaOutput, but the result of the monitor configuration
assignment algorithm, thus rename it to MetaCrtcAssignment and
MetaOutputAssignment.

The purpose for this is to be able to introduce a struct that actually
carries information about the CRTCs and outputs, as retrieved from the
backend implementations.

https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1287
2020-06-10 18:54:50 +00:00
Jonas Ådahl
f71316c850 output: Move configureable state to instance private
That is is_presentation, is_primary, is_underscanning and backlight.

The first three are set during CRTC assignment as they are only valid
when active. The other is set separately, as it is untied to
monitor configuration.

https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1287
2020-06-10 18:54:50 +00:00
Jonas Ådahl
0a6034ef3a monitor-manager: Remove 'mirror' capability
With per-CRTC views, there is nothing stopping NVIDA EGLStream based
rendering to not support monitor mirroring, so lets remove that
restriction.

https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1098
2020-03-18 00:46:20 +00:00
Jonas Ådahl
fe42d56db3 crtc: Move configured state to separate struct
To make it more reliable to distinguish between values that are read
from the backend implementation (which is likely to be irrelevant for
anything but the backend implementation), split out those values (e.g.
layout).

This changes the meaning of what was MetaCrtc::rect, to a
MetaCrtcConfig::layout which is the layout the CRTC has in the global
coordinate space.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/1042
2020-02-25 18:39:51 +01:00
Olivier Fourdan
c3c6668343 monitor-manager: Add get_vendor_name API
The monitor manager keeps the list of PnP Ids, add a new API to get the
vendor name from a given PnP ID.

https://gitlab.gnome.org/GNOME/mutter/issues/645
2019-06-28 11:19:22 +02:00
Jonas Ådahl
5c500ad402 backend: Move GPU ownership from the monitor manager to the backend
Lets work towards making MetaMonitorManager about managing monitors, and
not about managing GPUs. This changes other units to keep a pointer to
the backend instead of a monitor manager, in case their ownership
changed, or their main usage of the monitor manager was to look up GPUs.

https://gitlab.gnome.org/GNOME/mutter/issues/548
https://gitlab.gnome.org/GNOME/mutter/merge_requests/525
2019-06-20 13:31:55 +00:00
Jonas Ådahl
4cae9b5b11 monitor-manager: Clean up DPMS state tracking
DPMS is configured from a bit all over the place: via D-Bus, via X11 and
when reading the current KMS state. Each of these places did it slightly
differently, directly poking at the field in MetaMonitorManager.

To make things a bit more managable, move the field into a new
MetaMonitorManagerPrivate, and add helpers to get and set the current
value. Prior to this, there were for example situations where the DPMS
setting was changed, but without signal listeners being notified about
it.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/506
2019-04-02 13:49:59 +00:00
Dariusz Gadomski
cbb2a286f2 monitor-manager: Don't use wacky physical dimensions in display name 2019-02-04 17:41:36 +01:00
Marco Trevisan (Treviño)
e02fef8e2f meta: Hide libmutter symbols by default and selectively export them
Make meson link libmutter using -fvisibility=hidden, and introduce META_EXPORT
and META_EXPORT_TEST defines to mark a symbols as visible.
The TEST version is meant to be used to flag symbols that are only used
internally by mutter tests, but that should not be considered public API.

This allows us to be more precise in selecting what is exported and what is
not, without the need of a version-script file that would be more complicated
to maintain.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/395
2019-01-23 14:18:13 +01:00
Marco Trevisan (Treviño)
e352011830 MonitorManager: Use composition instead of inheriting from dbus skeleton
MonitorManager was inheriting from MetaDBusDisplayConfigSkeleton, this was
causing introspection to see this like a GDBus skeleton object exposing to
clients methods that were not required.

Also, this required us to export meta_dbus_* symbols to the library, while
these should be actually private.

So, make MetaMonitorManager to be just a simple GObject holding a skeleton
instance, and connect to its signals reusing most of the code with just few
minor changes.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/395
2019-01-23 14:12:07 +01:00
Niels De Graef
0478c225b7 Add some gtk-doc comments. 2019-01-06 21:57:16 +01:00
Robert Mader
676a8da005 monitor-transform: Move helper functions into their own file
The existing ones are statically inlined, so there is no .c file
right now.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/366
2019-01-05 14:15:23 +01:00
Niels De Graef
49cb691bb5 monitor-manager: remove get_edid_file() vfunc
It wasn't implemented by any subclass, it's not provided by DRM either.
And even if a subclass were to have only a file available, it could read
it into a GBytes as well and just use `read_edid()`.

Found this while working on !269.
2018-11-26 14:37:54 +01:00
Jonas Ådahl
2f4a68c8c3 Clean up include macros mess
The order and way include macros were structured was chaotic, with no
real common thread between files. Try to tidy up the mess with some
common scheme, to make things look less messy.
2018-11-06 17:17:36 +01:00
Bastien Nocera
951219650f backend: Move lid-is-closed handling to MetaBackend
Rather than handle UpClient in both MetaBackend (to reset the idletime
when the lid is opened), and in MetaMonitorManager and
MetaMonitorConfigManager (to turn the screen under the lid on/off
depending on its status), move the ability to get the lid status from
UPower or mock it in one place, in MetaBackend.
2018-07-18 10:17:36 +00:00
Bastien Nocera
49b23c7490 monitor-manager: Cache the last known value of "lid-is-closed"
Restarting UPower will make every property of UpClient emit a "notify"
signal (as a GDBusProxy would). Avoid mutter reconfiguring the displays
when upower restarts by caching the last known value of "lid-is-closed"
and only reconfiguring the displays if it actually changed.

This fixes a black out of the screen when UPower restarts.
2018-07-18 10:17:35 +00:00
Armin Krezović
1d5e37050d Stop using MetaScreen where it is unnecessary
https://bugzilla.gnome.org/show_bug.cgi?id=759538
2018-07-06 19:47:16 +02:00
Armin Krezović
e1c67a1824 Move monitor management API to MetaDisplay
This includes changing various users to use MetaDisplay directly, who
used MetaScreen only for this before.

https://bugzilla.gnome.org/show_bug.cgi?id=759538
2018-07-06 19:47:16 +02:00
Hans de Goede
e59ca14f6c monitor-manager: Take panel orientation into account when getting input matrix
If a LCD panel has a non normal orientation (mounted upside-down or 90
degrees rotated) then the kernel will report touchscreen coordinates with
the origin matching the native (e.g. upside down) coordinates of the panel.

Since we transparently rotate the image on the panel to correct for the
non normal panel-orientation, we must apply the same transform to input
coordinates to keep the aligned.

https://bugzilla.gnome.org/show_bug.cgi?id=782294
2017-12-25 17:01:45 +08:00
Hans de Goede
7917b083cb monitor-manager: Take drm-connector panel-orientation property into account
Some x86 clamshell design devices use portrait tablet LCD panels while
they should use a landscape panel, resoluting in a 90 degree rotated
picture.

Newer kernels detect this and rotate the fb console in software to
compensate. These kernels also export their knowledge of the LCD panel
orientation vs the casing in a "panel orientation" drm_connector property.

This commit adds support to mutter for reading the "panel orientation"
and transparently (from a mutter consumer's pov) fixing this by applying
a (hidden) rotation transform to compensate for the panel orientation.

Related: https://bugs.freedesktop.org/show_bug.cgi?id=94894

https://bugzilla.gnome.org/show_bug.cgi?id=782294
2017-12-25 17:01:45 +08:00
Jonas Ådahl
c1683073f1 backends: Split out CRTC/output management to MetaGpu
In order to eventually support multilpe GPUs with their own connectors,
split out related meta data management (i.e. outputs, CRTCs and CRTC
modes) into a new MetaGpu GObject.

The Xrandr backend always assumes there is always only a single "GPU" as
the GPU is abstracted by the X server; only the native backend (aside
from the test backend) will eventually see more than one GPU.

The Xrandr backend still moves some management to MetaGpuXrandr, in
order to behave more similarly to the KMS counterparts.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 18:05:20 -04:00
Jonas Ådahl
315a6f43d7 monitor-manager: Keep pointer to backend
Instead of accessing the global singleton, keep a pointer to the
backend in the MetaMonitorManager struct.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
518fb9fb5e backends: Split monitor manager creation into create and setup
The monitor manager instance was created and setup in one step; at
construction. This is problematic if, in the future, the monitor manager
creation can fail, as the monitor manager is created quite late.

To make it possible to in the future fail creating a monitor manager,
create the instance very early when initiating the backend, then on
post init backend setup, "setup" the monitor manager state, i.e. read
the current state and setup the stage.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
2db5505216 monitor-manager: Turn MetaCrtcMode into a GObject
Convert MetaCrtcMode from a plain struct to a GObject. This changes the
storage format, and also the API, as the API was dependent on the
storage format.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
f64fab1d2d monitor-manager: Make MetaCrtc a GObject
Turn MetaCrtc into a GObject and move it to a separate file. This
changes the storage format, resulting in changing the API for accessing
MetaCrtcs from using an array, to using a GList.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
a62e9f99a2 backends: Remave unused meta_monitor_manager_get_resources() API 2017-10-05 16:18:43 -04:00
Jonas Ådahl
9817a6aa47 Make MetaOutput a GObject
Turn MetaOutput into a GObject and move it to a separate file. This
changes the storage format, resulting in changing the API for accessing
MetaOutputs from using an array, to using a GList.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
22cdc8f414 monitor-manager: Pass config to derive from when updating state
When we update state, we might not have set the current config yet (for
example if the Xrandr assignment didn't change), so pass the monitors
config we should derive from instead of fetching it from the monitor
config manager.

https://bugzilla.gnome.org/show_bug.cgi?id=787477
2017-09-20 17:26:32 +08:00
Jonas Ådahl
0aa7405a2a monitor-manager: Fall back to minimum screen size of 640 x 480
When headless, we don't have any logical monitors to derive a screen
size from, but we can't set it to empty as that will cause issues with
the clutter stage, UI widget layout and other things. To avoid such
issues, just fall back to a 640 x 480 screen size when headless.

https://bugzilla.gnome.org/show_bug.cgi?id=730551
2017-08-30 13:09:38 +08:00
Jonas Ådahl
3005a400ca monitor-manager: Add helper for getting monitor from connector
This will be used later.

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 11:49:01 +08:00
Jonas Ådahl
e8a62861c9 Remove old monitor configuration system
Remove the old MetaMonitorConfig system and mark the new one as
non-experimental. This also removes the D-Bus property.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:20:53 +08:00
Rui Matos
3f9c5823cb backends: Add API to switch to predetermined monitor configurations
This will allows us to support the XF86Display key present on some
laptops, directly in mutter. This is also known, in evdev, as
KEY_SWITCHVIDEOMODE.

The common usage for this key is to alternate between a few well known
multi-monitor configurations though these aren't officially
standardized. As an example, Lenovo documents it as:

"Switches the display output location between the computer display
and an external monitor."

On this patch, we're just introducing the configurations that have been
implemented in g-s-d until now, which go a bit beyond the above
description.

https://bugzilla.gnome.org/show_bug.cgi?id=781906
2017-07-19 11:18:53 +02:00