Commit Graph

844 Commits

Author SHA1 Message Date
Hans de Goede
5d2b0bc0cc meta-input-settings: Fix strv memleak in find_logical_monitor()
The return value from g_settings_get_strv must be g_strfreev-ed.

https://bugzilla.gnome.org/show_bug.cgi?id=787836
2017-09-22 20:09:04 +02:00
Hans de Goede
7e3a780dcd monitor-config-manager-kms: Fix is_transform_handled
meta_monitor_manager_kms_is_transform_handled should checked the
transform passed as function argument, not the current crtc transform.

https://bugzilla.gnome.org/show_bug.cgi?id=787836
2017-09-22 20:09:04 +02:00
Hans de Goede
1035200f26 monitor-config-manager: Fix 90/270 degree rotation not working
When rotating 90/270 degrees we need to swap width and height. This fixes
the screen going black and the following errors showing in the journal:

gnome-shell[1097]: Failed to set CRTC mode 800x1280: No space left on device
gnome-shell[1097]: Failed to flip: Device or resource busy
gnome-shell[1097]: Failed to set CRTC mode 800x1280: No space left on device
gnome-shell[1097]: Failed to set CRTC mode 800x1280: No space left on device

When rotating a tablet with accelerometer 90/270 degrees.

https://bugzilla.gnome.org/show_bug.cgi?id=787836
2017-09-22 20:09:04 +02:00
Florian Müllner
f0c6c4eb1f screen-cast-stream-src: Adjust to pipewire API break
https://bugzilla.gnome.org/show_bug.cgi?id=787953
2017-09-21 18:14:26 +02:00
Jonas Ådahl
a35274ddb7 screen-cast-stream: Add stream parameters
For monitor streams, add position and size (in compositor coordinate
space) parameters.

https://bugzilla.gnome.org/show_bug.cgi?id=787715
2017-09-20 18:27:57 +08:00
Rui Matos
ab541e3e0f monitor-config-migration: Fix a minor leak when parsing fails
https://bugzilla.gnome.org/show_bug.cgi?id=787477
2017-09-20 17:26:32 +08:00
Jonas Ådahl
67ce04993e monitor: Add scale 1 if no other supported scale was added
We currently have a hard coded limit on logical monitor sizes, meant
for filtering out monitor scales that would result in awkward desktop
sizes. This has the side effect of also disqualifying scale 1 for
resolutions that themself are lower than the mentioned limit. To avoid
listing no supported scales, always add the fallback scale 1 if no
other was added.

https://bugzilla.gnome.org/show_bug.cgi?id=787477
2017-09-20 17:26:32 +08:00
Jonas Ådahl
22cdc8f414 monitor-manager: Pass config to derive from when updating state
When we update state, we might not have set the current config yet (for
example if the Xrandr assignment didn't change), so pass the monitors
config we should derive from instead of fetching it from the monitor
config manager.

https://bugzilla.gnome.org/show_bug.cgi?id=787477
2017-09-20 17:26:32 +08:00
Jonas Ådahl
8b022a5595 monitor-config-store: Maybe force save configuration on tear down
If there is a pending config file content replacement in progress on
tear down, cancel it and save it synchronously to avoid any data loss.

https://bugzilla.gnome.org/show_bug.cgi?id=787477
2017-09-20 17:26:32 +08:00
Jonas Ådahl
7a1393ba26 monitor-config-store: Don't leak when saving synchronously
We currently only save synchronously when running the test suite, but
should still not leak the generated config buffer. We also created the
cancellable but never used it if we saved synchronously, so lets stop
doing that too.

https://bugzilla.gnome.org/show_bug.cgi?id=787477
2017-09-20 17:26:20 +08:00
Jonas Ådahl
5ed954e6de monitor-config-store: Don't clear cancellable when cancelled
The cancellable should only be cleared if we weren't cancelled, as if
we were cancelled, the path cancelling have already cleared the
cancellable.

https://bugzilla.gnome.org/show_bug.cgi?id=787477
2017-09-20 17:25:00 +08:00
Jonas Ådahl
96572fbe6a monitor-config-migration: Don't destroy autoptr:ed hash table
It'll be destroyed automatically, so don't do it manually as well.

https://bugzilla.gnome.org/show_bug.cgi?id=787477
2017-09-20 17:25:00 +08:00
Jonas Ådahl
4ab47e72e5 monitor-config-migration: Clean up properly when deriving
We cleaned up an unused monitor config list, but what we should do is
clear up the logical monitor config list. This commit does that, as
well as removes the unused monitor config list.
2017-09-20 17:24:49 +08:00
Jonas Ådahl
70e0fd0b45 backends: Chain up some GObjectClass vfuncs
Various vfunc implementations was not chained up properly. This commit
fixes that.

https://bugzilla.gnome.org/show_bug.cgi?id=787477
2017-09-20 11:14:27 +08:00
Carlos Garnacho
743e8cc249 backends: Add some wiggle room for refresh rate comparisons
We have not enough control over the sources of the refresh rate
float variable to make == comparisons reliable, add some room
when comparing these.

https://bugzilla.gnome.org/show_bug.cgi?id=787668
2017-09-14 13:31:25 +02:00
Florian Müllner
aa30e11c8b screen-cast-stream-src: Remove malformed include
The mutter prefix is wrong - as the include isn't actually needed in
the header, just remove it altogether.
2017-09-08 17:54:44 +02:00
Jonas Ådahl
dd4ad4efc4 Revert "renderer-native: Destroy monitor framebuffers when suspending"
The reverted commit seems to cause
https://bugzilla.gnome.org/show_bug.cgi?id=787240 for some reason. Lets
be safe and revert it for now, as the code freeze is just around the
corner.

This partly (it doesn't reintroduce a whitespace issue) reverts commit
dbc63430d8.
2017-09-04 22:37:16 +08:00
Bastien Nocera
361bf847af build: Require libgudev >= 232
And remove the g_autoptr implementations in mutter itself.

https://bugzilla.gnome.org/show_bug.cgi?id=760670
2017-09-01 11:19:50 +02:00
Jonas Ådahl
522eec00cd monitor: Add foreach output helper and fix foreach crtc helper
The foreach CRTC monitor mode helper incorrectly iterated over outputs
without CRTC when non-tiled modes were set on tiled monitors. This was
not expected by callers, so fix the helper to only iterate over active
outputs (that has or should have a CRTC).

The test cases uses the incorrect behaviour of the foreach CRTC helper
to check that the disabled outputs mode are set to NULL, so add a
foreach output helper and change the tests to use that instead.

https://bugzilla.gnome.org/show_bug.cgi?id=730551
2017-08-30 13:09:38 +08:00
Jonas Ådahl
0aa7405a2a monitor-manager: Fall back to minimum screen size of 640 x 480
When headless, we don't have any logical monitors to derive a screen
size from, but we can't set it to empty as that will cause issues with
the clutter stage, UI widget layout and other things. To avoid such
issues, just fall back to a 640 x 480 screen size when headless.

https://bugzilla.gnome.org/show_bug.cgi?id=730551
2017-08-30 13:09:38 +08:00
Jonas Ådahl
a119e58773 backend: Only try to center pointer when there not headless
Don't attempt to center the pointer when there is nothing to center on.

https://bugzilla.gnome.org/show_bug.cgi?id=730551
2017-08-30 13:09:38 +08:00
Jonas Ådahl
8a32b42172 renderer/native: Round calculated framebuffer size before casting to int
Due to rounding issues, we can't assume a floating point calculation
will end up on an integer, even if we got the factor from the reverse
calculation. Thus, to avoid casting away values like N.999... to N,
when they should really be N+1, round the resulting floating point
calculation before casting it to int.

This fixes an issue where using the scale ~1.739 on a 1920x1080 mode
resulted in error when setting the mode, as the calculated size of the
framebuffer was only 1919x1080.

https://bugzilla.gnome.org/show_bug.cgi?id=786918
2017-08-30 13:07:11 +08:00
Jonas Ådahl
6e46ad9f3a remote-desktop, screen-cast: Fail session method calls from other peers
Only accept method calls on the session objects from the same peer that
created the session.

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 14:39:04 +08:00
Jonas Ådahl
921b18f713 screen-cast-session: Allow stand alone screen cast sessions
When a screen cast session is stand-alone, i.e. not created given a
remote desktop session managing it, allow calling the Start/Stop
methods to start and stop it.

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 14:39:04 +08:00
Jonas Ådahl
53175e8788 ScreenCast: Pass PipeWire stream node ID directly
As of commit 5f5ef3de2cdc816dab82cb7eb5d7171bee0ad2c5 in pipewire the
stream creator can find out the node ID of the stream it created.

So instead of using a special purpose entry to the info property box to
let the application discover stream by monitoring added nodes searching
for the given special purpose entry, just pass the node directly.

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 14:39:04 +08:00
Jonas Ådahl
920541fa26 screen-cast-stream-src: Only try to record frames when streaming
Only when the PipeWire stream state is 'PW_STREAM_STATE STREAMING'
should the signal be connected causing the src to maybe record a frame.

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 14:39:04 +08:00
Jonas Ådahl
9d8922764c screen-cast: Handle PipeWire errors
When the PipeWire context or stream ends up in an error state, signal
that the source has closed. This then triggers the stream and finally
the session to be closed too.

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 14:39:04 +08:00
Jonas Ådahl
97f2c7c161 Add remote desktop and screen cast functionality
This commit adds basic screen casting and remote desktoping
functionalty. This works by exposing two D-Bus API services:
org.gnome.Mutter.ScreenCast and org.gnome.Mutter.RemoteDesktop.

The remote desktop API is used to create remote desktop sessions. For
each session, a D-Bus object is created, and an application can manage
the session by sending messages to the session object. A remote desktop
session the user to emit input events using the D-Bus methods on the
session object. To get framebuffer content, the application should
create an associated screen cast session.

The screen cast API is used to create screen cast sessions. One can so
far either create stand-alone screen cast sessions, or a screen cast
session associated with a remote desktop session. A remote desktop
associated screen cast session is managed by the remote desktop session.

So far only remote desktop managed screen cast sessions are implemented.

Each screen cast session may have one or more streams. A screen cast
stream is a stream of buffers of some part of the compositor content.
So far API exists for creating streams of monitors and windows, but
only monitor streams are implemented.

When a screen cast session is started, the one PipeWire stream is
created for each screen cast stream created for the session. When this
has happened, a PipeWireStreamAdded signal is emitted on the stream
object, passing a unique identifier. The application may use this
identifier to find the associated stream being advertised by the
PipeWire daemon.

The remote desktop and screen cast functionality must be explicitly be
enabled at ./configure time by passing --enable-remote-desktop to
./configure. Doing this will build both screen cast and remote desktop
support.

To actually enable the screen casting and remote desktop, the user must
enable the experimental feature. See
org.gnome.mutter.experimental-features.

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 14:39:04 +08:00
Jonas Ådahl
3ce3a5a952 monitor: Add API to compare with old instance
When monitors changed, previous monitor instances are defunct, and any
reference holder should drop its reference. Sometimes they will want to
continue having a reference to the same monitor, so add this function
to make it possible to find it.

Currently the output and crtc references are invalid, as they are not
yet reference counted, so this can only look at cached fields.

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 14:38:20 +08:00
Jonas Ådahl
3005a400ca monitor-manager: Add helper for getting monitor from connector
This will be used later.

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 11:49:01 +08:00
Mario Sanchez Prada
e075242801 egl: Don't require eglGetPlatformDisplayEXT
Trying to unilaterally require eglGetPlatformDisplayEXT causes problems in
scenarios where this method is not available. Besides, this should only be
required on Wayland, so we can stop requiring it always and simply let the
eglGetPlatformDisplay() function error accordingly when needed.

https://bugzilla.gnome.org/show_bug.cgi?id=786619
2017-08-22 18:33:13 +02:00
Jonas Ådahl
14fe6e9c95 cursor-renderer-native: Don't use HW cursor on transformed logical monitor
The HW cursor plane can't do any transformations, and as we still don't
pre-transform any buffer before uploading to the cursor plane, we must
disable the HW cursor when a logical monitor is transformed.

This worked previously because the transform of a MetaCrtc did not
correspond to the transform of a CRTC, but the transform of the logical
monitor the CRTC was assigned to.

https://bugzilla.gnome.org/show_bug.cgi?id=786023
2017-08-21 21:20:19 +08:00
Jonas Ådahl
6584d06bb5 monitor-manager: Don't cancel confirm dialog on verifying
When another D-Bus call that just tries to verify a configuration is
made, don't cancel any active monitor configuration dialog, as doing so
would effectively confirm queried configuration.

https://bugzilla.gnome.org/show_bug.cgi?id=786023
2017-08-21 21:20:19 +08:00
Jonas Ådahl
a81d4aed7a backend/x11: Notify whenever the layout group changes
Will be used to trigger keyboard binding rebuild.

https://bugzilla.gnome.org/show_bug.cgi?id=786408
2017-08-21 21:19:18 +08:00
Jonas Ådahl
517488ef67 backends/native: Only emit layout group changed event when changed
Check that the layout group changed before emitting a changed event.
2017-08-21 21:19:18 +08:00
Jonas Ådahl
33f1706634 backend: Add API to get layout group
Add API to get the layout group (layout index) currently active. In the
native backend this is done by fetching the state directly from the
evdev backend; on X11 this works by listening for XkbStateNotify
events, caching the layout group value.

https://bugzilla.gnome.org/show_bug.cgi?id=786408
2017-08-21 21:19:18 +08:00
Jonas Ådahl
a6d67b164a x11: Open backend X11 connection ourself
Don't wait for clutter to initialize for connecting to X11; do it when
constructing the backend instance. This way we can later depend on
having an X11 connection earlier during initialization.

https://bugzilla.gnome.org/show_bug.cgi?id=786408
2017-08-21 21:19:18 +08:00
Jonas Ådahl
f950380202 monitor-manager-xrandr: Use G_DECLARE_FINAL_TYPE macro
Declare the MetaMonitorManagerXrandr type using the helper macro,
instead of manually.

https://bugzilla.gnome.org/show_bug.cgi?id=786408
2017-08-21 21:19:18 +08:00
Jonas Ådahl
35c9280fb6 monitor-manager: Try to restore previous config before regenerating
When opening a laptop lid, one will likely want to restore the
configuration one had prior to closing it, so when ensuring monitor
configuration, first try to see if the previously set configuration is
both complete (all connected monitors are configured) and applicable
(it is a valid configuration) and only try to generate a new from
scratch if that failed.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
b140e7fbeb monitor-config-manager: Keep short history of configurations
In order to go back in monitor configurations, save them to a history.
The history is implemented as a max 3 element long queue, where newly
set configurations are pushed to the head, and old are popped from the
tail.

The difference between using a single previous config reference and a
queue is that we can now remember the configuration used prior to a
D-Bus triggered configuration when the user discarded the configuration.

This will later be used to restore a previous configuration when a
laptop lid is opened.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
bc3162460f Migrate old monitor configuration files to new system
This commit changes the new configuration system to use monitors.xml
instead of monitors-experimental.xml. When starting up and the
monitors.xml file is loaded, if a legacy monitors.xml file is
discovered (it has the version number 1), an attempt is made to migrate
the stored configuration onto the new system.

This is done in two steps:

1) Parsing and translation of the old configuration. This works by
parsing file using the mostly the old parser, but then translating the
resulting configuration structs into the new configuration system. As
the legacy configuration system doesn't carry over some state (such as
tiling and scale used), some things are not available. For tiling, the
migration paths makes an attempt to discover tiled monitors by
comparing EDID data, and guessing what the main tile is. Determination
of the scale of a migrated configuration is postponed until the
configuration is actually applied. This works by flagging the
configuration as 'migrated'.

2) Finishing the migration when applying. When a configuration with the
'migrated' flag is retrieved from the configuration store, the final
step of the migration is taken place. This involves calculating the
preferred scale given the mode configured, while making sure this
doesn't result in any overlapping logical monitor regions etc.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
27a4f9f862 monitor-manager/kms: Use connector id to find old output
The zero-initialized winsys id was incorrectly used as the key to find
the old output to base active/primary state from, which would never
succeed unless the winsys id happened to be 0. Fix this by using the
winsys id that will be used, i.e. the connector id.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
88f2441330 monitor-manager: Fix output variable naming
Fix the last case of using the variable name "meta_output" for a
MetaOutput.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
ab04286c6b monitor-manager/x11: Don't complain about 'normal' transform
The 'normal' transform has the value 0, so the g_warn_if_fail()
expression failed. Correct it so that it doesn't complain when no
transform is checked.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
e8a62861c9 Remove old monitor configuration system
Remove the old MetaMonitorConfig system and mark the new one as
non-experimental. This also removes the D-Bus property.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:20:53 +08:00
Jonas Ådahl
9ac87b36c1 monitor-manager/xrandr: Fix name inconsistencies
MetaOutputs should be "output" and external types should be named as
such, i.e. XRandr outputs are renamed to "xrandr_output".

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:20:30 +08:00
freeroot
12792f99a0 Add tag-and-drag setting from libinput into mutter
The problem is that libinput offers the possibility to not enabled
dragging when tap-to-click is enabled but mutter doesn't. For people who
have a sensitive touchpad and who like tap-to-click option, dragging is
launched even when you don't want it : for example, when you select a
folder, most of the time the folder is dragging whereas just selected or
when you want to select some lines of a text file, several lines are
moved as a cut-paste which is not expected and erase datas.

To fix it, you need to have the possibility to desactivate the drag
option when you use tap-to-click in mutter. Because it's already a
specification of libinput, it remains to add it to mutter.
Implementation with X11 is added too.

https://bugzilla.gnome.org/show_bug.cgi?id=775755
2017-08-20 09:27:28 +08:00
Rui Matos
420a712ad5 meta-monitor: Make supported scales determination saner
Scales below 1 and scales that result in a too small logical monitor
size don't make sense. We also don't need so many intermediate scales.

https://bugzilla.gnome.org/show_bug.cgi?id=786474
2017-08-18 18:41:01 +02:00
Jonas Ådahl
dbc63430d8 renderer-native: Destroy monitor framebuffers when suspending
When suspending (i.e. VT switching away, the GDM gnome-shell instance
gets hidden, or changing user), destroy the onscreen and offscreen
monitor framebuffers. When resuming, the stage views and framebuffers
will be recreated anyway.

https://bugzilla.gnome.org/show_bug.cgi?id=786299
2017-08-16 13:17:43 +08:00
Daniel Stone
b7b5fb293d wayland: Add zwp_linux_dmabuf_v1 support
https://bugzilla.gnome.org/show_bug.cgi?id=785262
Signed-off-by: Daniel Stone <daniels@collabora.com>
2017-08-01 19:05:50 +08:00
Cosimo Cecchi
1455c402b9 monitor-manager: add API to get the display configuration timeout
Instead of hardcoding this into two different places, add an API so that
gnome-shell can fetch it.

https://bugzilla.gnome.org/show_bug.cgi?id=767805
2017-07-31 15:41:15 +01:00
Rui Matos
3f9c5823cb backends: Add API to switch to predetermined monitor configurations
This will allows us to support the XF86Display key present on some
laptops, directly in mutter. This is also known, in evdev, as
KEY_SWITCHVIDEOMODE.

The common usage for this key is to alternate between a few well known
multi-monitor configurations though these aren't officially
standardized. As an example, Lenovo documents it as:

"Switches the display output location between the computer display
and an external monitor."

On this patch, we're just introducing the configurations that have been
implemented in g-s-d until now, which go a bit beyond the above
description.

https://bugzilla.gnome.org/show_bug.cgi?id=781906
2017-07-19 11:18:53 +02:00
Jonas Ådahl
32fd1e8c08 monitor-manager: Let the MetaMonitor derive the whole layout
Instead of letting MetaMonitor derive the logical monitor size, then
using the main monitor for the position, just let MetaMonitor derive
the whole layout including the position. This means it can deal with
tiled monitors better, for example when the main output (the output
always active when the monitor is active) is not the origin output (the
output with tile position (0, 0)).

https://bugzilla.gnome.org/show_bug.cgi?id=781723
2017-07-19 17:06:17 +08:00
Carlos Garnacho
f852d2b0eb backends: Extend pad action label checks to rings/strips
This way the pad OSD can obtain the keycombos that are mapped to these
for labeling purposes.

https://bugzilla.gnome.org/show_bug.cgi?id=782033
2017-07-17 19:43:13 +02:00
Carlos Garnacho
ef13ee4488 backends: Map tablet pad rings/strips to action settings
Just like we do for buttons, with a few twists. These have 2 directions
mappable to different keycombos, and are affected by the current mode
in their group.

https://bugzilla.gnome.org/show_bug.cgi?id=782033
2017-07-14 22:30:49 +02:00
Florian Müllner
8b5d34b24a monitor-manager: Shut up a compiler warning
Add a default switch statement to make it clear that 'transform'
won't be used uninitialized.
2017-07-14 16:56:43 +02:00
Rui Matos
7360f51ee8 meta-monitor-manager: Add API to rotate the current configuration
This will allows us to support the XF86RotateWindows key present on
some laptops directly in mutter.

https://bugzilla.gnome.org/show_bug.cgi?id=781906
2017-07-14 15:31:20 +02:00
Rui Matos
6ae42f3845 monitor-manager: Hook MetaOrientationManager to change the config
On orientation changes we'll apply the appropriate monitor transform
to the current configuration if possible.

https://bugzilla.gnome.org/show_bug.cgi?id=781906
2017-07-14 15:31:20 +02:00
Rui Matos
26b66826dc meta-monitor-config: Add API to rotate the current config
This will allow us to do automatic rotation of the builtin display if
that's the only active monitor.

https://bugzilla.gnome.org/show_bug.cgi?id=781906
2017-07-14 15:31:20 +02:00
Rui Matos
6d082bf442 monitor-config-manager: Add API to rotate the current config
This will allow us to do automatic rotation of the builtin display if
that's the only active monitor.

https://bugzilla.gnome.org/show_bug.cgi?id=781906
2017-07-14 15:31:20 +02:00
Rui Matos
aad2280309 backends: Add a MetaOrientationManager class
This basically moves g-s-d's orientation plugin into mutter so that
eventually g-s-d doesn't need to build monitor configurations by
itself anymore.

https://bugzilla.gnome.org/show_bug.cgi?id=781906
2017-07-14 15:31:20 +02:00
Jonas Ådahl
777963eeb6 monitor-manager: Don't set current config if only verifying
When verifying if a configuration is applicable, don't set it as
current when applying succeeded, or else reverting to a previous
configuration doesn't work after having verified.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
49c5228655 DisplayConfig: Add support for interlaced modes
Differentiate between non-interlaced and interlaced modes. This is done
by appending an "i" after the resolution part of the mode ID, and
adding a 'is-interlaced' (b) property to the mode properties.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
a9c1c6d9fb Fix a couple of wrong indentations
https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
0a8e108f10 DisplayConfig: Replace mode 'u' flags with 'a{sv}' property bag
To be more flexible without having to change any D-Bus type signatures
in the future, replace the 'uint' flags value (currently determining
whether a mode is current and/or preferred) with a variant lookup table.

The keys 'is-current' (b) and 'is-preferred' (b) replace the existing
flags.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
859b01fc39 DisplayConfig: Specify mode ID string instead of mode spec
To be able to add more modes types that happen to have the same
resolution and refresh rate, change the API to specify modes using an
ID string. The ID string is temporary, and only works for associating a
mode for the monitor instance that it was part of.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
41eea5a942 monitor-config: Handle fractional scale precision loss
When calculating sizes given some size and a fractional logical monitor
scale with precision loss, round the result of the floating point
calculation to the closest integer, as otherwise we might end up with
result smaller by 1 if there was a loss of precision when calculating
the scale.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
197401fbf8 cursor-renderer: Track cursor position using floats
To be able to render the pointer cursor sprite at sub-(logical)-pixel
positions, track the pointer position using floats instead of ints.
This also requires users of the cursor sprite rect to deal with
floating points, when e.g. finding the logical monitor etc.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
aa5d8ac68c monitor-config-store: Don't discard scale < 1.0 configurations
It's not the task of the XML parser to decide this; let the code
listing allowed scales sort out configurations with invalid scales.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
67eb289a6a monitor-manager: Find the supported scales from one passed
When passing scales over D-Bus, we'll loose some precision. To set the
correct scale, use the configured scale and look up the one actually
supported by the monitor mode, and use that. To match the supported one
with the configured one, the difference must be within rounding error
range.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
5f2bb43061 backend/native: Don't double-scale pointer motions on scaled monitors
We manually scaled pointer motions when they travel over a scaled
monitor. When a stage view of a monitor is also scaled, in practice this
meant we scaled twice. Avoid this by only manually scaling the pointer
motion when stage views are not scaled.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Marco Trevisan (Treviño)
3e8d0204bd monitor: Dynamically calculate supported scales per resolution
When using logical sized monitors we are allowed to use fractional scaling
but only if the resulting scaled logical monitor size is in integer form.
So, in order to get this, we allow to scale the monitor to up to
8 fractional values per integer, doing some computation in order to
fetch the nearest values which are closer to the scaling factors we can
permit.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
b2a530b326 DisplayConfig: Make supported scales per mode
This changes the API to pass supported scales per mode instead of
providing a global list. This allows for more flexible scaling
scenarious, where a scale compatible with one mode can still be made
available even though another mode is incompatible.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
10b0351a59 Add support for rudimentary fractional scaling
When the logical layout mode is used, allow configuring the scaling to
be non-integer. Supported scales are so far hard coded to include at
most 1, 1.5 and 2, and scales that doesn't result in non-fractional
logical monitor sizes are discarded.

Wayland outputs are set to have scale ceil(actual_scale) meaning well
behaving Wayland clients will provide buffers with buffer scale 2, thus
being scaled down to the fractional scale.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
b64c69e4bc logical-monitor: Make scale a float
To support fractional scaling, the logical monitor scale must be stored
as a float. No other functional changes is part of this commit.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
c2e49f1bb5 clutter: Change stage view scale to be float
To support fractional scaling, change the stage view scale to be a
float instead of an int. Also change the places where it is retrieved
and used when scaling things.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
88cae8bd3d settings: Manage our own font DPI
Previously gnome-shell listened on the Xft Xsettings via GTK+s
GtkSettings to get the font DPI setting. The Xsetting might not
be what we want, and we should not rely on Xsettings when we don't need
to, so lets manage it ourself.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Carlos Garnacho
a6ec2b1d42 backends: Set error when opening /sys file fails
The caller in clutter really expects an error if fd==-1, so make
sure we set one here. Otherwise we get a nice crash in addition to
the failure to open the /sys file. Also, retry on EINTR.

https://bugzilla.gnome.org/show_bug.cgi?id=784881
2017-07-14 12:28:32 +02:00
Carlos Garnacho
4b8dd51c4d backends: Fix dangling callback not being disconnected
This fixes possible crashes if configuration is changed on a device that
was added and then removed.

https://bugzilla.gnome.org/show_bug.cgi?id=784881
2017-07-13 19:05:44 +02:00
Carlos Garnacho
10b30eaba5 backend: Set mapping-mode on X11 pen/eraser devices
And use it in the generic code for the checks about whether mapping to
an specific display applies or not.

https://bugzilla.gnome.org/show_bug.cgi?id=784402
2017-07-12 23:43:23 +02:00
Jonas Ådahl
1303c626b1 renderer-native: Fix compilation when EGLDevice renderer not enabled
When --enable-egl-device is not passed to ./configure, the
egl_device_error will not be declared; don't try to free it when its not
declared.
2017-07-07 17:59:20 +08:00
Miguel A. Vico
7eea82d3d7 MetaRendererNative: Give EGLDevice backend priority over GBM
With GLVND, whenever we have both Mesa's and NVIDIA's drives installed
in the system, initializing the GBM backend will always succeed,
regardless of what GPU you have on your system.

This is due to GBM's software rendering fallback.

It seems better to initialize the EGLDevice backend first, which will
fail to find a device match when given a non-NVIDIA GPU.

https://bugzilla.gnome.org/show_bug.cgi?id=784272
2017-07-07 11:55:18 +08:00
Carlos Garnacho
ce989976fa backends: Apply tablet settings on all tablet device types during startup
This skipped the device types that are in use on X11.

https://bugzilla.gnome.org/show_bug.cgi?id=782027
2017-07-03 13:57:35 +02:00
Jason Gerecke
74882b2502 backends/x11: Account for non-zero device origin when setting tablet area
Wacom's display tablets typically do not have (0,0) coincident with the top
left corner of the screen. This "outbound" area must be taken into account
when setting the area or else an unexpected offset of the pointer will
occur.

https://bugzilla.gnome.org/show_bug.cgi?id=784009
2017-07-03 13:49:14 +02:00
Jason Gerecke
a4cef8586c backends/native: Interpret tablet padding as being input-centric
It is possible to interpret the ammount of padding provided to the
*_set_tablet_area functions in two different and incompatible ways. The X11
backend effectively treats them as being input-centric (i.e., the padding
defines the size of the "dead zone" on the tablet) while the native backend
has an output-centric viewpoint (i.e., the padding defines the size of the
"dead zone" on the display) viewpoint. This difference in opinion causes the
cursor offset to change when switching between Xorg and a Wayland sessions.

The calibration utility within g-c-c does its calculations with an input-
centric viewpoint, so this patch modifies the native backend to work
correctly with these values. To change viewpoints, we can simply invert
the scale and negate the offset. It should be noted that this function
also forgot to apply scaling to the offsets (as required by the matrix
transform done by libinput) which would have further compounded the
cursor offset issue under Wayland.

https://bugzilla.gnome.org/show_bug.cgi?id=784009
2017-06-20 23:42:38 +02:00
Carlos Garnacho
9b9bb9cf86 backends: Fix output cycling in non display-attached tablets
It would only allow to alternate between the logical monitors, we actually
want to return NULL here so it can cycle to the whole span of monitors.

https://bugzilla.gnome.org/show_bug.cgi?id=782032
2017-06-20 22:02:04 +02:00
Carlos Garnacho
dc5b2e396c backends: Fix typo
Instead of checking all MetaMonitors in the monitor manager, we want to
look (as the function name says) in the MetaMonitors contained in the
given logical monitor.

Otherwise, it will return TRUE for every logical monitor, given we are
querying for an existing EDID.

https://bugzilla.gnome.org/show_bug.cgi?id=782032
2017-06-20 22:02:04 +02:00
Carlos Garnacho
d23275bc76 backends/x11: Handle left-handed mode on pen/eraser devices correctly
Due to the pen/eraser device separation in X11, CLUTTER_TABLET_DEVICE does
not apply there, this device type is only used in native/evdev. Checking
for CLUTTER_PEN/ERASER_DEVICE makes the left-handed mode correctly applied
on tablets.

https://bugzilla.gnome.org/show_bug.cgi?id=782027
2017-06-20 22:02:04 +02:00
Carlos Garnacho
48e820235e backends/x11: Fix c&p issue in tablet area calculation
instead of filling in the last array value, it overwrote the previous one.

https://bugzilla.gnome.org/show_bug.cgi?id=781703
2017-06-20 22:02:04 +02:00
Christian Kellner
7938f41c11 monitor: invert logic for 4k TV scaling
For devices connected via HDMI (supposedly TVs) we want have a
scale factor of 1 if we are *below* the smallest 4k resolution
width (not equal or above) and do the scaling factor computation
if we are above the limit. This check was apparently wrongly
ported from gnome-settings-daemon.

Based of a patch by Caolan McNamara <caolanm@redhat.com>.

https://bugzilla.gnome.org/show_bug.cgi?id=777347
2017-06-07 14:03:03 +02:00
Ikey Doherty
e9c9ee844c backends/x11: Ensure reply is initialised to NULL 2017-05-31 19:15:39 -04:00
Bastien Nocera
f5f0ff0a2f monitor-manager: Fix crash when UPower is not available
Don't access the upower client if it doesn't exist

https://bugzilla.gnome.org/show_bug.cgi?id=780407
2017-05-31 16:11:24 +02:00
Jonas Ådahl
82325cbcfd monitor: Don't get the monitor manager from the backend
We will both create and destroy monitors during initialization (when
using the X11 backend), so don't try to access the monitor manager from
the backend, but store a pointer to it instead.

It's stored in MetaMonitor even though only MetaMonitorTiled uses it,
mostly because it makes more sense to store such a pointer there.

https://bugzilla.gnome.org/show_bug.cgi?id=781723
2017-05-26 14:32:43 +08:00
Jonas Ådahl
c32e2d17d9 monitor: Handle tiled monitors where (0, 0) is not the main output
In some circumstances, the origin tile (0, 0) is not the one that
should be used to drive the monitor when using a non-tiled mode. Update
MetaMonitorTiled to support this case. It also seems to be so that the
preferred mode might be some low resolution or bogus mode on these
monitors, so also adapt MetaMonitorTiled to manage to ignore the
preferred mode of a tiled monitor if the preferred mode doesn't use
both tiles.

https://bugzilla.gnome.org/show_bug.cgi?id=781723
2017-05-26 14:32:43 +08:00
Jonas Ådahl
2b05748d5c monitor: Move get_suggested() behind behind vfunc
Only support suggested monitor positioning if the monitor is non-tiled.
Normally this functionality is used by virtual machines to provide a
hint of how to place the virtual monitors, and they don't tend to use
tiled monitors anyway.

https://bugzilla.gnome.org/show_bug.cgi?id=781723
2017-05-26 14:32:43 +08:00
Jonas Ådahl
cd775929bf monitor: Move tiled CRTC mode identification into helper
It'll be used in more places later.

https://bugzilla.gnome.org/show_bug.cgi?id=781723
2017-05-26 14:32:43 +08:00
Jonas Ådahl
7303a78b06 monitor: Generate spec struct earlier
By generating the spec struct earlier, code executed later can use the
fields in the spec.

https://bugzilla.gnome.org/show_bug.cgi?id=781723
2017-05-26 14:32:43 +08:00
Jonas Ådahl
07b8cc0773 monitor: Fix naming of spec generation function
It was at one point referred to as 'id', but was changed to 'spec', but
the name of this function was not updated.

https://bugzilla.gnome.org/show_bug.cgi?id=781723
2017-05-26 14:32:43 +08:00
Jonas Ådahl
1bb0e18042 monitor-manager/xrandr: Allow configuring scales on X11 too
This commit makes it possible to configure logical monitor scale also
when running on top of an X11 server using Xrandr. An extra property
'requires-globla-scale' is added to the D-Bus API is added to instruct
a configuration application to only allow setting a global logical
monitor scale.

This is needed to let gsd-xsettings use the configured state to set a
XSettings state that respects the explicit monitor configuration.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-05-26 14:31:48 +08:00
Jonas Ådahl
3b097c7e77 monitor-manager/kms: Move scale calculation to MetaMonitor
The scale calculation doesn't really have anything to do with KMS, and
eventually we'll want to have mutter calculate the monitor scale for
non-KMS backends too, so move the scale calculation to MetaMonitor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-05-26 14:31:48 +08:00