Commit Graph

116 Commits

Author SHA1 Message Date
Jonas Ådahl
2718699ccc backend: Move settings into a new MetaSettings object
Introduce MetaSettings and add the settings managed by MetaBackend into
the new object. These settings include: experimental-features and UI
scaling factor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-05-26 14:31:48 +08:00
Marco Trevisan (Treviño)
183f4b0c13 MetaMonitorManager: ignore hotplug_mode_update at startup
hotplug_mode_update is used (mostly by VMs nowadays, and
VMware has implemented it) to inform that modes list (including
the preferred one) might change after an uevent.

However, when using MetaMonitorConfigManager we should
ignore this value at initialization level, or mutter
won't restore the configured values at startup.

https://bugzilla.gnome.org/show_bug.cgi?id=783073
2017-05-25 16:50:29 +08:00
Rui Matos
612432ac3e monitor-manager: Fix format-security gcc warnings 2017-04-12 16:53:30 +02:00
Jonas Ådahl
c214eb15bf monitor-manager: Check active monitors when looking for logical monitor
An inactive monitor will not be assigned to a logical monitor, so don't
try to match against those. This avoids a dereferencing a NULL when the
main output of an inactive monitor doesn't have an assigned CRTC.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 23:53:51 +08:00
Jonas Ådahl
de61da16ae monitor-manager: Reconfigure when 'scale-monitor-framebuffer' is toggled
When the experimental feature 'scale-monitor-framebuffer' is enabled or
disabled, reconfigure the monitors.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:51 +08:00
Jonas Ådahl
bdcb395b33 DisplayConfig: Add 'supports-changing-layout-mode' property
This property may be used by a client to determine whether it is
allowed to change the layout mode.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:51 +08:00
Jonas Ådahl
1caa7f7627 monitor-manager: Add public API to get logical monitor from connector
This adds a function to be used by gnome-shell to get the logical
monitor given a connector name. For now, use the same index integer
method to reference a logical monitor, but this should be revisited by
providing a better API later.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:51 +08:00
Jonas Ådahl
15dd23a323 monitor-manager: Fix gtk-doc of .._get_monitor_for_output
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:51 +08:00
Jonas Ådahl
04d7fcf60d DisplayConfig: Add display-name monitor property
This is the same property as the one associated with an output in
GetResources.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
9755cd469c DisplayConfig: Make naming convention consistent
Always use hyphens as delimit words in property keys. Underscore to
delimit words in method arguments.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
1bdadfa3e1 backend: Add API to get UI scaling
The UI scaling depends on whether the framebuffers are scaled. Enable
the caller to determine the what scale its UI should be drawn in, in
relation to the stage coordinate space by calling this function. A new
singal "ui-scaling-factor-changed" is added in order to liston for for
changes.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
6c8b103a7b DisplayConfig: Add "is_builtin" monitor property
Add a per-monitor property allowing the application to determine
whether the monitor is builtin or not, e.g. a laptop panel.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
95d0117784 monitor-manager: Hook up config manager to display config confirmation
Make it possible to confirm or cancel the new configuration also when
the new API is used.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
af4017de49 monitor-manager: Derive logical monitor position from top left CRTC
Derive the logical monitor position not by looking at the main output
(the (0, 0) tile), but the one that is placed on the top-left corner.
This might be the non-main output on certain transformations.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
0ac2eba4d3 DisplayConfig: Add logical monitor transforms
Add the transform as a logical monitor parameter, both when getting the
current state and applying a new configuration. The transform is defined
to be identical to MetaMonitorTransform.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:49 +08:00
Jonas Ådahl
472a434212 monitor-config-manager: Support logical monitor transforms
Add support for rotated monitors. This is done per logical monitor, as
every monitor assigned to a logical monitor must be transformed in the
same way. This includes being transformed on the same level; e.g. if
the backend does not support transforming any monitor of a logical
monitor natively, then all monitors will be transformed using the
offscreen intermediate framebuffer.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:49 +08:00
Jonas Ådahl
d38c4c1f2d logical-monitor: Track whether the logical monitor is transformed
Keep track of the logical monitor transform. When a logical monitor is
transformed, all of its monitors are also transformed in the same way.
A logical monitor can either be transformed on the CRTC level, or using
an offscreen intermediate buffer. In both cases will the logical
monitor be transformed, but only in the latter will the view be
transformed.

MetaCrtcs::transform currently does not represent whether the CRTC is
configured to be transformed or not; only when the backend can handle
it does it correctly correspond to the actual CRTC configuration. This
is intended to change with MetaMonitorConfigManager.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:49 +08:00
Jonas Ådahl
0c64c35a8a monitor-manager: Make the config manager an 'experimental feature'
Instead of using a environment variable, add a new 'experimental
feature' gsetting keyword "monitor-config-manager" that enables the use
of the new MetaMonitorConfigManager. This commit also makes it possible
to switch between the two systems without restarting mutter.

The D-Bus API is disabled when the experimental feature is not enabled,
and clients trying to access it will get a access-denied error in
response. A new property 'IsExperimentalApiEnabled' is added to let the
D-Bus client know whether it is possible to use the experimental API or
not.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
57acbc53fb legacy-monitor-config: Let the manager listen on lid closed changes
This is in preparation for making config-manager work alongside the
legacy configuration system.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
8163ca6821 Add support for scaled logical monitor framebuffers
This commit adds support for rendering onto enlarged per logical
monitor framebuffers, using the scaled clutter stage views, for HiDPI
enabled logical monitors.

This works by scaling the mode of the monitors in a logical monitors by
the scale, no longer relying on scaling the window actors and window
geometry for making windows have the correct size on HiDPI monitors.

It is disabled by default, as in automatically created configurations
will still use the old mode. This is partly because Xwayland clients
will not yet work good enough to make it feasible.

To enable, add the 'scale-monitor-framebuffer' keyword to the
org.gnome.mutter.experimental-features gsettings array.

It is still possible to specify the mode via the new D-Bus API, which
has been adapted.

The adaptations to the D-Bus API means the caller need to be aware of
how to position logical monitors on the stage grid. This depends on the
'layout-mode' property that is used (see the DisplayConfig D-Bus
documentation).

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
0952409de4 monitor-manager: Always set current config when apply succeeds
No reason making any caller do it.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
f25f14351c monitor-manager: Make max screen size optional
Make the concept of maximum screen size optional, as it is not
necessarily a thing on all systems (e.g. when using the native backend
and stage views).

The meta_monitor_monitor_get_limits() function is replaced by a
meta_monitor_manager_get_max_screen_size() which fails when no screen
limit is available. Callers and other users of the previous max screen
size fields are updated to deal with the fact that the limit is
optional.

The new D-Bus API is changed to move it to the properties bag, where
its absence means there is no applicable limit.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
691e7951ea DisplayConfig: Add new API for configuring monitors
Add a new D-Bus API that uses the state from GetCurrentState to
configure high level monitors, instead of low level CRTCs and
connectors. So far persistent configuration is not implemented, as
writing to the configuration store is still not supported.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
9a5b94a340 monitor-manager: Use better error code when using the wrong API
It has nothing to do with permissions, so 'not-supported' is a bit
better.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
079b125430 DisplayConfig: Group logical monitor parameters a bit better
Move around the parameters, just to put the always-there fields before
the monitor array and property box.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
770a5a5bff DisplayConfig: Drop width/height from logical monitor
It is redundant, and either side still need to do the equivalent
calculations, so lets drop it.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
ea4438284f DisplayConfig: Add 'properties' to GetCurrentState
Adds compositor wide DisplayConfig properties bag, and add a
"supports-mirroring" property.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
9003a42df3 monitor-manager: Add supported scales to D-Bus API
Let the configuring client know what scales are supported by the
display server.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
3b46345db4 monitor-manager: Make scale floats in D-Bus API
We don't want to limit ourself to whole integers for configuration, as
that'd mean it wouldn't be able to provide configurations for
fractional scalings. Thus, change scales to be referred to as floats
instead of ints.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
6b2a111428 DisplayConfig: Add an optional 'is_underscanning' monitor property
Add a 'is_underscanning' entry to the properties map, if the monitor
supports underscanning. The client should assume a monitor does not
support underscanning if no property was added.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
bc56971e18 DisplayConfig: Add new API for getting current state
Add a D-Bus method for getting the current monitor and logical monitor
state. Currently does not contain information about transforms or any
limitations (such as limited CRTCs and cloning).

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
fcc0288f0c monitor-manager: Let the backends handle no configuration
Let the backends decide whether to just rebuild a derived state, or use
the NULL config to rebuild an empty logical state.

This also changes the expected screen size values of the no-outputs
test; as this case is actually handled now.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
a393a614a1 monitor-manager: Remove 'scale' from MetaOutput
Replace the 'scale' of an output with a vfunc on the MetaMonitorManager
class that takes a monitor and a monitor mode which calculates the
scale. On X11 this always returns 1, on KMS, the old formula is used.
On the dummy and test backends, the already configured values are
returned.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:46 +08:00
Jonas Ådahl
409c92a68f monitor-manager: Update the monitor mode state before the logical state
This means we can use up to date monitor mode data when generating the
logical state.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:46 +08:00
Carlos Garnacho
efae039ad9 backends: Refactor MetaScreenDirection guessing into separate function
Make it a helper MetaLogicalMonitor API, and use it on the
MetaMonitorManager.

https://bugzilla.gnome.org/show_bug.cgi?id=778119
2017-03-27 12:57:56 +02:00
Jonas Ådahl
cdedd017d6 input-settings: Use logical monitors instead of outputs
A MetaOutput is a connector, not exactly a monitor or a region on the
stage; for example tiled monitors are split up into multiple outputs,
and for what is used in input settings, that makes no sense. Change
this to use logical monitors instead of outputs.

https://bugzilla.gnome.org/show_bug.cgi?id=779745
2017-03-09 10:17:30 +08:00
Jonas Ådahl
944339f6a5 monitor-manager: Expose whether the backend handles a transform
Expose via a new API whether the transform on a logical monitor is
handled by the backend. This was previously only exposed only in the
native backend. This will be used to emulate not supporting transforms
in the backend in the nested backend.

https://bugzilla.gnome.org/show_bug.cgi?id=779745
2017-03-09 10:17:30 +08:00
Jonas Ådahl
615587cd06 monitor-manager: Split logical monitor creation
Split up logical monitor cration into derived (when derived from
current underlying configuration) and non-derived (when creating from a
logical monitor configuration). This avoids that type of logic in the
logical monitor creation function.

https://bugzilla.gnome.org/show_bug.cgi?id=779745
2017-03-09 10:17:30 +08:00
Jonas Ådahl
9b4e1903e1 monitor-config-manager: Prefer to use stored config
If not explicitly set by the backend, prefer to use the stored config
instead of creating a new one, if available.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
3f994646f2 monitor-config-manager: Handle headless setup gracefully
Handle headless setup gracefully by having no logical monitors. This
commit only makes the monitor management code deal with it; other areas
may still not be able to handle it.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
f19cb6a610 monitor-config-manager: Handle laptop lid being closed
Handle configuring when the laptop lid is closed. This is so far
handled by creating a linear configuration while ignoring the laptop
panel. Changing the current configuration will come later.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
f7b6271d86 monitor-manager: Move UpClient signal listening into monitor manager
Move the UpClients notify::lid-is-closed signal handling into
MetaMonitorManager, and put the getter behind a vfunc. This means
Placing it behind a vfunc allows custom backends to implement it
differently; for example the test backend can mock the state.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
a0af7e94a6 monitor-config-manager: Add support for suggested configuration
Create a suggested configuration, if such configuration is provided.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
644ee666f6 Introduce new monitor configuration system
The new monitor configuration system (MetaMonitorConfigManager) aims to
replace the current MetaMonitorConfig. The main difference between the
two is that MetaMonitorConfigManager works with higher level input
(MetaMonitor, MetaMonitorMode) instead of directly looking at the CRTC
and connector state. It still produces CRTC and connector configuration
later applied by the respective backends.

Other difference the new system aims to introduce is that the
configuration system doesn't manipulate the monitor manager state; that
responsibility is left for the monitor manager to handle (it only
manages configuration and creates CRTC/connector assignments, it
doesn't apply anything).

The new configuration system allows backends to not rely on deriving the
current configuration from the CRTC/connector state, as this may no longer be
possible (i.e. when using KMS and multiple framebuffers).

The MetaMonitorConfigManager system is so far disabled by default, as
it does not yet have all the features of the old system, but eventually
it will replace MetaMonitorConfig which will at that point be removed.
This will make it possible to remove old hacks introduced due to
limitations in the old system.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
ee0677a021 monitor-manager: Let backend implementations handle inital config
How the initial configuration is done depends on the backend, so let
them do it themself.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
9ceeddd952 monitor: Track current monitor mode
Track what monitor mode is the current. This is derived from the mode
of the corresponding CRTC's.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
536ae8430b monitor-manager: Add API to get monitor from monitor spec
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
aaddf44d45 monitor-manager: Add API to find primary monitor
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
b70187c2d9 monitor-manager: Move meta_monitor_manager_ function to right place
Move a meta_monitor_manager_ function to meta-monitor-manager.c where
it belongs.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
c041851fa5 monitor-manager: Rename read_current_config to read_current_state
The function meta_monitor_manager_read_current_config() was renamed to
meta_monitor_manager_read_current_state() as it does not read any
configuration, but reads the current state as described by the backend.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00