Commit Graph

189 Commits

Author SHA1 Message Date
Jonas Ådahl
9003a42df3 monitor-manager: Add supported scales to D-Bus API
Let the configuring client know what scales are supported by the
display server.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
3b46345db4 monitor-manager: Make scale floats in D-Bus API
We don't want to limit ourself to whole integers for configuration, as
that'd mean it wouldn't be able to provide configurations for
fractional scalings. Thus, change scales to be referred to as floats
instead of ints.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
6b2a111428 DisplayConfig: Add an optional 'is_underscanning' monitor property
Add a 'is_underscanning' entry to the properties map, if the monitor
supports underscanning. The client should assume a monitor does not
support underscanning if no property was added.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
bc56971e18 DisplayConfig: Add new API for getting current state
Add a D-Bus method for getting the current monitor and logical monitor
state. Currently does not contain information about transforms or any
limitations (such as limited CRTCs and cloning).

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
fcc0288f0c monitor-manager: Let the backends handle no configuration
Let the backends decide whether to just rebuild a derived state, or use
the NULL config to rebuild an empty logical state.

This also changes the expected screen size values of the no-outputs
test; as this case is actually handled now.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
a393a614a1 monitor-manager: Remove 'scale' from MetaOutput
Replace the 'scale' of an output with a vfunc on the MetaMonitorManager
class that takes a monitor and a monitor mode which calculates the
scale. On X11 this always returns 1, on KMS, the old formula is used.
On the dummy and test backends, the already configured values are
returned.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:46 +08:00
Jonas Ådahl
409c92a68f monitor-manager: Update the monitor mode state before the logical state
This means we can use up to date monitor mode data when generating the
logical state.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:46 +08:00
Carlos Garnacho
efae039ad9 backends: Refactor MetaScreenDirection guessing into separate function
Make it a helper MetaLogicalMonitor API, and use it on the
MetaMonitorManager.

https://bugzilla.gnome.org/show_bug.cgi?id=778119
2017-03-27 12:57:56 +02:00
Jonas Ådahl
cdedd017d6 input-settings: Use logical monitors instead of outputs
A MetaOutput is a connector, not exactly a monitor or a region on the
stage; for example tiled monitors are split up into multiple outputs,
and for what is used in input settings, that makes no sense. Change
this to use logical monitors instead of outputs.

https://bugzilla.gnome.org/show_bug.cgi?id=779745
2017-03-09 10:17:30 +08:00
Jonas Ådahl
944339f6a5 monitor-manager: Expose whether the backend handles a transform
Expose via a new API whether the transform on a logical monitor is
handled by the backend. This was previously only exposed only in the
native backend. This will be used to emulate not supporting transforms
in the backend in the nested backend.

https://bugzilla.gnome.org/show_bug.cgi?id=779745
2017-03-09 10:17:30 +08:00
Jonas Ådahl
615587cd06 monitor-manager: Split logical monitor creation
Split up logical monitor cration into derived (when derived from
current underlying configuration) and non-derived (when creating from a
logical monitor configuration). This avoids that type of logic in the
logical monitor creation function.

https://bugzilla.gnome.org/show_bug.cgi?id=779745
2017-03-09 10:17:30 +08:00
Jonas Ådahl
9b4e1903e1 monitor-config-manager: Prefer to use stored config
If not explicitly set by the backend, prefer to use the stored config
instead of creating a new one, if available.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
3f994646f2 monitor-config-manager: Handle headless setup gracefully
Handle headless setup gracefully by having no logical monitors. This
commit only makes the monitor management code deal with it; other areas
may still not be able to handle it.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
f19cb6a610 monitor-config-manager: Handle laptop lid being closed
Handle configuring when the laptop lid is closed. This is so far
handled by creating a linear configuration while ignoring the laptop
panel. Changing the current configuration will come later.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
f7b6271d86 monitor-manager: Move UpClient signal listening into monitor manager
Move the UpClients notify::lid-is-closed signal handling into
MetaMonitorManager, and put the getter behind a vfunc. This means
Placing it behind a vfunc allows custom backends to implement it
differently; for example the test backend can mock the state.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
a0af7e94a6 monitor-config-manager: Add support for suggested configuration
Create a suggested configuration, if such configuration is provided.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
644ee666f6 Introduce new monitor configuration system
The new monitor configuration system (MetaMonitorConfigManager) aims to
replace the current MetaMonitorConfig. The main difference between the
two is that MetaMonitorConfigManager works with higher level input
(MetaMonitor, MetaMonitorMode) instead of directly looking at the CRTC
and connector state. It still produces CRTC and connector configuration
later applied by the respective backends.

Other difference the new system aims to introduce is that the
configuration system doesn't manipulate the monitor manager state; that
responsibility is left for the monitor manager to handle (it only
manages configuration and creates CRTC/connector assignments, it
doesn't apply anything).

The new configuration system allows backends to not rely on deriving the
current configuration from the CRTC/connector state, as this may no longer be
possible (i.e. when using KMS and multiple framebuffers).

The MetaMonitorConfigManager system is so far disabled by default, as
it does not yet have all the features of the old system, but eventually
it will replace MetaMonitorConfig which will at that point be removed.
This will make it possible to remove old hacks introduced due to
limitations in the old system.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
ee0677a021 monitor-manager: Let backend implementations handle inital config
How the initial configuration is done depends on the backend, so let
them do it themself.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
9ceeddd952 monitor: Track current monitor mode
Track what monitor mode is the current. This is derived from the mode
of the corresponding CRTC's.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
536ae8430b monitor-manager: Add API to get monitor from monitor spec
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
aaddf44d45 monitor-manager: Add API to find primary monitor
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
b70187c2d9 monitor-manager: Move meta_monitor_manager_ function to right place
Move a meta_monitor_manager_ function to meta-monitor-manager.c where
it belongs.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
c041851fa5 monitor-manager: Rename read_current_config to read_current_state
The function meta_monitor_manager_read_current_config() was renamed to
meta_monitor_manager_read_current_state() as it does not read any
configuration, but reads the current state as described by the backend.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
b59a8b1de3 monitor-manager: Move configuration paths behind 'legacy' functions
In preparation of replacing the configuration system with one working
with high level monitors instead of low level outputs etc, move
configuarion handling code into obviously named function (containing
the word 'legacy'.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
e3b9fe7e58 monitor-manager: Use MetaMonitor to check laptop panel status
Instead of looking at the current configuration, just find the
MetaMonitor of the laptop display panel and check the currest status
directly.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
78799e58d2 monitor-manager: Make tiled Xrandr monitors based on monitors
Don't deal with adding/removing tiled Xrandr monitors in the generic
backend, but leave it to the Xrandr backend. The tiled monitor will
itself notify the backend when such a monitor is added and removed.

Tiled Xrandr monitors are now based no MetaMonitor instead of
MetaLogicalMonitor. This means that mirrored tiled monitors will now be
represented correctly.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
bf8b4e9927 monitor-manager: Generate logical monitors from monitors
Instead of using crtcs and outputs to generate logical monitors, use
the ready made monitor abstraction that hides irrelevant things such as
monitor tiling etc.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
d9a0f2a88d monitor-manager: Generate a monitor abstraction from outputs and crtcs
Generate a set of "monitors" abstracting the physical concepts. Each
monitor is built up of one or more outputs; multiple outputs being
tiled monitors. Logical monitors will later be built from these.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
4e812410cc monitor-manager: Move logical monitor into its own file
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
0873e3812b backends: Rename MetaMonitorMode to MetaCrtcMode
The MetaMonitorMode referred to the mode of a CRTC, and with the future
introduction of a MetaMonitor, theh old name would be confusing.
Instead call it what it is.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
1650c35e38 monitor-manager: Rename MetaCRTC(Info) to MetaCrtc(Info)
Change to follow the naming convention used everywhere else. This means
changing CRTC to Crtc even though it is an abbreviation.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
f519093f89 monitor-manager: Initialize tiled logical monitor scale
The logical monitor scale were not initialized properly when created
for a tiled monitor. Set it to the scale of the main monitor tile.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
6de3e4a07e Turn MetaLogicalMonitor into a GObject
This will make it easier to move various manually managed data and data
now in MetaLogicalMonitor into GObject QData fields.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
1fb0e8e9bb monitor-manager: Store logical monitors in a GList
Instead of storing the logical monitors in an array and having users
either look up them in the array given an index or iterate using
indices, put it in a GList, and use GList iterators when iterating and
alternative API where array indices were previously used.

This allows for more liberty regarding the type of the logical monitor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
20b8743f21 monitor-manager: Refactor tiled monitor assembly code
Refactor the tiled monitor assembly code (that constructs a logical
monitor out of tiling information. Part of the reason is to move away
from array based storage, part is to make the code easier to follow,
and part is to separate logical monitor construction from list
manipulation.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
c98bab8327 monitor-manager: Make logical monitor from point API take floats
Change meta_monitor_manager_get_logical_monitor_at() to use floats,
replace users of meta_monitor_manager_get_monitor_at_point() to use the
API that returns a logical monitor and remove the now unused function.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
a422d6fe08 Move logical monitor neighbor API into monitor manager
Move the last piece of monitor grid getter API to the monitor manager
away from MetaScreen. The public facing API are still there, but are
thin wrappers around the MetaMonitorManager API.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
af616c96d4 Move more logical monitor getters from the screen to the monitor manager
Turning a rectangle into a logical monitor also has nothing to do with
the screen (MetaScreen) so move it to MetaMonitorManager which has that
information.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
2df4ebff47 Put logical monitor grid lookup API in MetaMonitorManager
Don't falsely assume the screen has anything to do with the monitor
grid, and thus move the related API to MetaMonitorManager.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
e659b07c39 MetaMonitorManager: Add API turning monitor index into logical monitor
This is the current equivalent of looking up the logical monitor in the
logical monitor array using the number, but eventually that will be
deprecated, and before that done differently, so add a temporary helper
for the places that has not been ported yet.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:51 +08:00
Jonas Ådahl
c936056663 MetaMonitorManager: Track primary monitor by pointer instead of index
Instead of keeping an index in an array to keep track of the current
primary logical monitor, just keep a pointer instead.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:51 +08:00
Jonas Ådahl
e22bbd4b14 MetaScreen: Remove redundant copy of logical monitors array
It was just pointer to the actual list; having to synchronize a list of
logical monitors with the actual monitors managed by the backend is
unnecessary.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:51 +08:00
Jonas Ådahl
842ff5d6aa Rename MetaMonitorInfo MetaLogicalMonitor
In preparation for further refactorizations, rename the MetaMonitorInfo
struct to MetaLogicalMonitor. Eventually, part of MetaLogicalMonitor
will be split into a MetaMonitor type.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:51 +08:00
Jonas Ådahl
1f657d2c81 monitor-manager: Always set the monitor info scale
https://bugzilla.gnome.org/show_bug.cgi?id=769505
2016-08-12 14:58:39 +08:00
Jonas Ådahl
d7b87799c8 backend: Ensure the backend gets notified of monitor state having changed
Being a listener to a signal, it is inconvenient to enforce order of
execution between different signal listeners. If there are things in
the backend that should be updated before various other signal
handlers, make sure so is done by emitting the signal after having
explicitly notified the backend.

https://bugzilla.gnome.org/show_bug.cgi?id=768976
2016-07-20 14:23:48 +08:00
Rui Matos
1141929bc5 backends: Add flags to MetaMonitorMode
And export them in the DBus API since they're useful for
gnome-control-center.

https://bugzilla.gnome.org/show_bug.cgi?id=763832
2016-05-13 18:44:45 +02:00
Florian Müllner
ed5c3b39ee monitor-manager: Add get_is_builtin_display_on()
Wrap the existing laptop_display_is_on() method in a public function
that gnome-shell can use to query whether a builtin output is present
and enabled.

https://bugzilla.gnome.org/show_bug.cgi?id=765267
2016-04-21 21:16:16 +02:00
Florian Müllner
b6f11fa8b8 monitor-config: Update laptop heuristics to match GnomeRROutput
gnome-desktop's GnomeRROutput class has heuristics to classify a display
as builtin similar to our own[0]. The two heuristics don't quite match
though, so different core components can end up with a different view
on the current display configuration. Minimize that risk by adding a
couple of rules that bring the two heuristics closer together.

[0] https://git.gnome.org/browse/gnome-desktop/tree/libgnome-desktop/gnome-rr.c#n1674

https://bugzilla.gnome.org/show_bug.cgi?id=765267
2016-04-21 17:36:22 +02:00
Florian Müllner
ab6c008e3e monitor-manager: Expose output_is_laptop() method
We currently duplicate the heuristics of whether an output is considered
a laptop or not. Avoid this by sharing a small helper method.

https://bugzilla.gnome.org/show_bug.cgi?id=765267
2016-04-21 17:36:22 +02:00
Rui Matos
82bdd1e353 monitor-manager: Fix the max potential number of logical monitors
The max potential number of logical monitors (i.e. MetaMonitorInfos)
is the number of CRTCs, not the number of outputs.

In cases where we have more enabled CRTCs than connected outputs we
would end up appending more MetaMonitorInfos to the GArray than the
size it was initialized with which means the array would get
re-allocated rendering invalid some MetaCRTC->logical_monitor pointers
assigned previously and thus ending in crashes later on.

https://bugzilla.gnome.org/show_bug.cgi?id=751638
2015-11-29 19:15:37 +01:00
Rui Matos
bff75b64be monitor-manager: Expose a few helpers to clear structs
These are useful for child classes to unwind cleanly when constructing
their structures.

https://bugzilla.gnome.org/show_bug.cgi?id=756796
2015-10-30 17:47:00 +01:00
Florian Müllner
67d3a7a2d7 meta-monitor-manager: Remove bogus condition from check
An unsigned number is never smaller than 0, so we don't have to
check for it.
2015-09-24 03:08:23 +02:00
Rui Matos
2fb8da0d5a backends/monitor-manager: Validate EDID strings
Some monitors return a bunch of bytes on their display descriptor
which aren't valid utf8 and thus we fail to serialize them later on
for the DisplayConfig DBus API.

Let's fall back to the stringified product code and serial number in
that case.

https://bugzilla.gnome.org/show_bug.cgi?id=752673
2015-07-21 16:42:53 +02:00
Jonas Ådahl
441efd17ce MetaMonitorInfo: Provide scale information
Tracking back from the monitor to the output every time we need to
figure out the scale of a window on a monitor is inconvenient, so
propagate the scale from the output to the monitor it is associated
with.

https://bugzilla.gnome.org/show_bug.cgi?id=744934
2015-07-16 11:53:40 +08:00
Cosimo Cecchi
94bce5a00f monitor-manager: add a property to discover if underscan is supported
So that clients such as the control center can decide to hide an
underscanning checkbutton when the output does not support it.

Support in the KMS / native backend to come later...
2015-07-01 18:20:57 -07:00
Dave Airlie
9f65edd4f5 backend/x11: add support for setting randr 1.5 monitors
This interface allows us to propogate back the constructed
monitors to randr using the randr 1.5 protocol. Apps
should pick it up from there.
2015-06-01 09:38:13 -07:00
Dave Airlie
ea2496c80a monitors: construct tiled monitors info
The monitors info structure is created from the tiled outputs
and this is used as the central storage for info about a monitor
as opposed to the output state.

It appears at least the EDID mm w/h is for the whole monitor and
not per tile.
2015-06-01 09:38:13 -07:00
Dave Airlie
2a8563ab23 monitors: adds expose tile info as a property over dbus interface
This just adds 8 uint32s as a property to the dbus protocol.

This will be used by gnome-desktop to get the tile info.
2015-06-01 09:38:13 -07:00
Jasper St. Pierre
4d80a4cc31 Use more g_autofoo throughout mutter 2015-05-29 17:18:35 -07:00
Jasper St. Pierre
48bf807430 monitor-manager-kms: Add support for underscan 2015-04-27 17:58:38 -07:00
Tomeu Vizoso
cc53d48fa8 MonitorManager: Add support for overscan compensation
Some DRM drivers have added a consistent set of properties that
allow compensating for the overscan that some TVs do, without the
user being able to disable.
2015-04-27 17:17:15 -07:00
Carlos Garnacho
8188cddcf7 backends: Add meta_monitor_manager_get_monitor_at_point()
This function returns the monitor_info index corresponding to the given
coordinates, or -1 if none is found at that point. The native backend
has been changed in places where it could make use of this function.

https://bugzilla.gnome.org/show_bug.cgi?id=746896
2015-03-30 14:00:31 +02:00
Rui Matos
7f19db1f7b monitor-manager: Expose a method to get a monitor from an output
This method will be used by gnome-shell to resolve an output ID
(exposed from the org.gnome.Mutter.DisplayConfig DBus API) to a
logical monitor.

https://bugzilla.gnome.org/show_bug.cgi?id=743745
2015-01-30 13:13:49 -05:00
Rui Matos
3f2d658f20 monitor-manager: Expose MetaMonitorManager to introspection
This just exposes the type and the singleton getter necessary to make
it available to introspection. We'll expose more functionality as it
becomes needed.

https://bugzilla.gnome.org/show_bug.cgi?id=743745
2015-01-30 13:13:49 -05:00
Rui Matos
ad90b7dd2f monitor-manager: Initialize MetaOutput even when we can't get the EDID
Otherwise we'll crash later when building a MetaConfiguration.

https://bugzilla.gnome.org/show_bug.cgi?id=743412
2015-01-27 14:42:45 +01:00
Carlos Garnacho
71c4138933 monitor-manager: Add method to find an output matrix
This will be useful to determine input device matrices for touchscreens
and tablets.

https://bugzilla.gnome.org/show_bug.cgi?id=739397
2015-01-18 13:32:28 -08:00
Carlos Garnacho
625d3de2ee backends: Make KMS EDID information equal to X11's
EDID parsing has been refactored to a common meta_output_parse_edid()
function, which ensures the extracted information is the same on both KMS
and X11 backend, so it can be used consistently on eg. settings values.

https://bugzilla.gnome.org/show_bug.cgi?id=742882
2015-01-14 12:16:18 +01:00
Jasper St. Pierre
c5940580ed monitor-manager: Use connector_type instead of name sniffing 2014-12-29 17:15:23 -08:00
Jasper St. Pierre
d514e8ab41 monitor-manager: Add a connector-type property
This is so gnome-settings-daemon
2014-12-29 16:30:54 -08:00
Rui Matos
b63413e5b0 Revert "monitor-manager: Remove needless code"
It turns out that this was wrong because MetaWindow->monitor points to
the old monitor infos and they are needed to position windows in the
new configuration which happens in a monitors-changed handler.

This reverts commit e1704acda4.
2014-10-23 16:38:26 +02:00
Rui Matos
e1704acda4 monitor-manager: Remove needless code
Nothing uses this. Signal handlers have access to the new monitor
infos built by make_logical_config() .

https://bugzilla.gnome.org/show_bug.cgi?id=738630
2014-10-16 20:39:16 +02:00
Jasper St. Pierre
cc8462969d monitor-manager: Put the common hotplug code in a common path as well
So we can reuse it in the KMS backend.
2014-10-14 13:56:48 -07:00
Jasper St. Pierre
989bb6ebb1 monitor-manager: Simplify reading the current configuration
Make a wrapper in MetaMonitorManager that handles freeing the existing
configuration for us.
2014-10-14 13:56:48 -07:00
Jasper St. Pierre
f3595ebd08 monitor-manager: Make sure to emit PropertiesChanged for PowerSaveMode
We overrode the property for PowerSaveMode, which meant that gdbus's
auto-generated PropertiesChanged code wasn't being run.

This really confused gnome-rr and gnome-settings-daemon's power plugin
about the current DPMS state of the display, since they used their
cached PowerSaveMode properties, and never saw a PropertiesChanged being
emitted.

If a display was on, they set it to off, and then set it back on, the
setting back on would never fire, since they thought the display was
already off.

To fix this, remove our custom property override and just respond to
notifications on the object.

Namely, this fixes the DPMS management when receiving notifications so
that it now properly times out.
2014-09-25 20:17:53 -06:00
Rui Matos
7d54631ebf backends: Make MetaBackend available to introspection
This moves meta-backend.h under meta/ and, for now, just exposes to
introspection the methods that we actually need in gnome-shell.

https://bugzilla.gnome.org/show_bug.cgi?id=734301
2014-08-07 11:31:59 +02:00
Jasper St. Pierre
eb952819c2 monitor: Don't use wl_output_transform in our APIs
Invent our own API so we can build without Wayland headers.
2014-07-13 11:35:01 -04:00
Jasper St. Pierre
af135c0b0b monitor-manager: Rename output_id to winsys_id
The output_id is more of an opaque identifier for the monitor, based on
its underlying ID from the windowing system. Since we also use the term
"output_id" for the output's index, rename our use of the opaque cookie
"output_id" to "winsys_id".
2014-07-01 13:24:34 -04:00
Jasper St. Pierre
110c79d10e monitor-manager: Rename output_id to output_index
The term "output_id" is already used as an opaque ID.
2014-07-01 13:01:02 -04:00
Jasper St. Pierre
b9d867cb86 monitor-manager: Remove duplicate variable definition 2014-07-01 13:00:57 -04:00
Jasper St. Pierre
25a16c3379 Remove trailing whitespace 2014-05-02 09:34:48 -04:00
Jasper St. Pierre
1dc8a7eca3 monitor: Remove handle_xevent as a generic method 2014-04-23 12:15:12 -04:00
Jasper St. Pierre
c44b1d730d backends: Move MonitorManager creation to MetaBackend as well 2014-04-21 20:25:21 -04:00
Jasper St. Pierre
2d6bcf3885 monitor-manager: Remove debugging META_DEBUG_MULTIMONITOR hook
It's outdated and incorrect: META_TYPE_MONITOR_MANAGER is now an
abstract class.
2014-04-21 20:25:20 -04:00
Bastien Nocera
d53e04f4c8 Name all timeouts and idles
Better names can be used once we make more use of them.

https://bugzilla.gnome.org/show_bug.cgi?id=727979
2014-04-10 18:59:46 +02:00
Giovanni Campagna
42f267bb50 MonitorManager: make sure to pass the right sizes to vararg functions
A gulong is not enough to get 64 bits in all arches, so we must
cast it, or we can corrupt the stack.

This was downstream bug bugzilla.redhat.com/show_bug.cgi?id=1002055

https://bugzilla.gnome.org/show_bug.cgi?id=707267
2014-04-09 12:14:26 -07:00
Jasper St. Pierre
899d4d8477 monitor-manager: Move default get_edid_file / read_edid to base class
These are also used by the native manager.
2014-04-01 10:24:34 -04:00
Jasper St. Pierre
bce1d5117b Start creating different subdirectories for each backend 2014-03-31 23:44:47 -04:00
Jasper St. Pierre
fd392cc1e7 Remove "xrandr" from the name of the generated DBus files
It's about generic display config, not XRandR specifically.
2014-03-31 23:44:47 -04:00
Jasper St. Pierre
229360b248 Start molding out a new src/backends/ dir
Right now this just has all of the files in one directory. We'll
be introducing more structure to this in the future, and build
a proper backend system.
2014-03-31 22:11:00 -04:00