We already ran a Wayland client to test various Wayland paths. What was
missing to also run a X11 client was to hook in the X11 async waiter
wires, so do that and run both types of clients.
https://bugzilla.gnome.org/show_bug.cgi?id=790207
As with the Wayland display name, to avoid clashes with already an
running Xwayland or Xorg instance, override the X11 display name to
something less likely to cause a clash.
https://gitlab.gnome.org/GNOME/mutter/issues/193
Meson uses the 'dependencies' field to determine and
parallelize build steps, but that isn't entirely true
with 'link_with'; this might cause a race condition
when generating header files while trying to build
them.
Fix that by only using 'dependencies' instead of 'link_with'.
This commit adds meson build support to mutter. It takes a step away
from the three separate code bases with three different autotools setups
into a single meson build system. There are still places that can be
unified better, for example by removing various "config.h" style files
from cogl and clutter, centralizing debug C flags and other configurable
macros, and similar artifacts that are there only because they were once
separate code bases.
There are some differences between the autotools setup and the new
meson. Here are a few:
The meson setup doesn't generate wrapper scripts for various cogl and
clutter test cases. What these tests did was more or less generate a
tiny script that called an executable with a test name as the argument.
To run particular tests, just run the test executable with the name of
the test as the argument.
The meson setup doesn't install test files anymore. The autotools test
suite was designed towards working with installed tests, but it didn't
really still, and now with meson, it doesn't install anything at all,
but instead makes sure that everything runs with the uninstalled input
files, binaries and libraries when running the test suite. Installable
tests may come later.
Tests from cogl, clutter and mutter are run on 'meson test'. In
autotools, only cogl and clutter tests were run on 'make check'.
This is the filename convention you get when you define a shared module
in meson, and since there is no particular reason to not include the
"lib" prefix, lets make it easier to port it over. While at it,
de-duplicate the retrieval of the plugin name.
The order and way include macros were structured was chaotic, with no
real common thread between files. Try to tidy up the mess with some
common scheme, to make things look less messy.
testboxes was a binary that did unit testing, but it wasn't integrated
to the test system, so in effect, it was never run. Instead integrate it
into the other mutter unit tests. This includes changing a few of
meta_warning()s into g_warning()s so that the GTest framework can handle
them.
When a transient window is destroyed, the expected behavior is that
focus is passed to the ancestor if possible. This was broken for
quite a while until the previous commit, so add a test case to make
sure it doesn't happen again.
https://gitlab.gnome.org/GNOME/mutter/issues/15
This test aims at checking that the transient relationship set using the
xdg-foreign API is respected by mutter and that no crash occurs, such as
the one in issue !174.
Note: the crash from issue !174 occurs only if "attach_modal_dialogs" is
set, so one has to change that default value to "true" to be able to
trigger the crash:
gsettings set org.gnome.mutter attach-modal-dialogs true
Related: https://gitlab.gnome.org/GNOME/mutter/issues/174
Add a "set_parent_exported" command to test the xdg-foreign support, so
that we can add a test which uses the GDK API for exported window:
`gdk_wayland_window_set_transient_for_exported()`
That will allow to detect if transient is applied correctly between
foreign windows and detect possible crashes such as issue !174.
Related: https://gitlab.gnome.org/GNOME/mutter/issues/174
Rather than handle UpClient in both MetaBackend (to reset the idletime
when the lid is opened), and in MetaMonitorManager and
MetaMonitorConfigManager (to turn the screen under the lid on/off
depending on its status), move the ability to get the lid status from
UPower or mock it in one place, in MetaBackend.
Previously we relied on the test-client to make sure that a window was
shown. For X11, we did not need to do anything, but for Wayland we had
to make sure we had drawn the first frame, otherwise mutter wouldn't
have a buffer making the window not showable.
Doing it this way doesn't work anymore however, since the 'after-paint'
event will be emitted even if we didn't actually paint anything. This is
the case with current Gtk under Wayland, where we won't draw until the
compositor has configured the surface. In effect, this mean we'll get a
dummy after-paint emission before the first frame is actually painted.
Instead, move the verification that a "show" command has completed by
having the test-runner wait for a "shown" signal on the window, which is
emitted in the end of meta_window_show(). This requires an additional
call to gdk_display_sync() in the test-client after creating the window,
to make sure that the window creation vents has been received in the
compositor.
- Moved xdisplay, name and various atoms from MetaDisplay
- Moved xroot, screen_name, default_depth and default_xvisual
from MetaScreen
- Moved some X11 specific functions from screen.c and display.c
to meta-x11-display.c
https://bugzilla.gnome.org/show_bug.cgi?id=759538
Changing the test monitor managers ability to rotate CRTCs in one test
affected the next test. Avoid leaking such state by resetting it before
each test. To continue passing, some tests needed to be updated
regarding to still pass.
https://bugzilla.gnome.org/show_bug.cgi?id=788915
Add a test case that checks that we don't try to revert to a
laptop-panel-only configuration after closing the lid after an external
monitor is connected.
https://bugzilla.gnome.org/show_bug.cgi?id=788915
Check that if there are multiple modes with the same ID (resolution,
refresh rate and handled flags) we correctly add the preferred mode to
the list of monitor modes.
https://bugzilla.gnome.org/show_bug.cgi?id=789153
In order to eventually support multilpe GPUs with their own connectors,
split out related meta data management (i.e. outputs, CRTCs and CRTC
modes) into a new MetaGpu GObject.
The Xrandr backend always assumes there is always only a single "GPU" as
the GPU is abstracted by the X server; only the native backend (aside
from the test backend) will eventually see more than one GPU.
The Xrandr backend still moves some management to MetaGpuXrandr, in
order to behave more similarly to the KMS counterparts.
https://bugzilla.gnome.org/show_bug.cgi?id=785381
Move finding, opening and managment of the KMS file descriptor to
MetaMonitorManagerKms. This means that the monitor manager creation can
now fail, both if more than one GPU with connectors is discovered, or
if finding or opening the primary GPU fails.
https://bugzilla.gnome.org/show_bug.cgi?id=785381
Instead of passing it around or fetching the singleton, keep a pointer
to the monitor manager that owns the CRTC. This will eventually be
replaced with a per GPU/graphics card object.
https://bugzilla.gnome.org/show_bug.cgi?id=785381
Instead of passing it around or fetching the singleton, keep a pointer
to the monitor manager that owns the output. This will eventually be
replaced with a per GPU/graphics card object.
https://bugzilla.gnome.org/show_bug.cgi?id=785381
Convert MetaCrtcMode from a plain struct to a GObject. This changes the
storage format, and also the API, as the API was dependent on the
storage format.
https://bugzilla.gnome.org/show_bug.cgi?id=785381
Turn MetaCrtc into a GObject and move it to a separate file. This
changes the storage format, resulting in changing the API for accessing
MetaCrtcs from using an array, to using a GList.
https://bugzilla.gnome.org/show_bug.cgi?id=785381
Turn MetaOutput into a GObject and move it to a separate file. This
changes the storage format, resulting in changing the API for accessing
MetaOutputs from using an array, to using a GList.
https://bugzilla.gnome.org/show_bug.cgi?id=785381
Check that configurations where monitors are disabled are properly
used. Also test that old configurations with explicitly disabled
outputs are migrated properly.
https://bugzilla.gnome.org/show_bug.cgi?id=787629
When we update state, we might not have set the current config yet (for
example if the Xrandr assignment didn't change), so pass the monitors
config we should derive from instead of fetching it from the monitor
config manager.
https://bugzilla.gnome.org/show_bug.cgi?id=787477