display: Make sure ping serials are never reused
Using a timestamp twice in a row (e.g. when activating two windows in response to the same event or due to other bugs) will break the window detection and show a close dialog on the wrong window. This is a grave error that should never happen, so check every timestamp before sending the ping for uniqueness and if the timestamp was already used and its ping is still pending, log a warning message and don't send the ping. https://gitlab.gnome.org/GNOME/mutter/merge_requests/891
This commit is contained in:
parent
0bf9727a31
commit
9b58033375
@ -2063,6 +2063,7 @@ void
|
|||||||
meta_display_ping_window (MetaWindow *window,
|
meta_display_ping_window (MetaWindow *window,
|
||||||
guint32 serial)
|
guint32 serial)
|
||||||
{
|
{
|
||||||
|
GSList *l;
|
||||||
MetaDisplay *display = window->display;
|
MetaDisplay *display = window->display;
|
||||||
MetaPingData *ping_data;
|
MetaPingData *ping_data;
|
||||||
|
|
||||||
@ -2076,6 +2077,19 @@ meta_display_ping_window (MetaWindow *window,
|
|||||||
if (!meta_window_can_ping (window))
|
if (!meta_window_can_ping (window))
|
||||||
return;
|
return;
|
||||||
|
|
||||||
|
for (l = display->pending_pings; l; l = l->next)
|
||||||
|
{
|
||||||
|
MetaPingData *ping_data = l->data;
|
||||||
|
|
||||||
|
if (serial == ping_data->serial)
|
||||||
|
{
|
||||||
|
meta_warning ("Ping serial %u was reused for window %s, "
|
||||||
|
"previous use was for window %s.\n",
|
||||||
|
serial, window->desc, ping_data->window->desc);
|
||||||
|
return;
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
ping_data = g_new (MetaPingData, 1);
|
ping_data = g_new (MetaPingData, 1);
|
||||||
ping_data->window = window;
|
ping_data->window = window;
|
||||||
ping_data->serial = serial;
|
ping_data->serial = serial;
|
||||||
|
Loading…